6AG1332-5HF00-2AB0 Siemens - SIPLUS S7-300 SM 332 40-pole based on 6ES7332-5HF00-0AB0 with conformal coating, -25…+70 °C, analog output isolated, 8 AQ, U/I; diagnostics; resolution 11/12 bits, 40-pole, removing and inserting possible with active backplane bus

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£2,100.85 Exc. VAT
£2,521.02 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1332-5HF00-2AB0
Product Description SIPLUS S7-300 SM 332 40-pole based on 6ES7332-5HF00-0AB0 with conformal coating, -25…+70 °C, analog output isolated, 8 AQ, U/I; diagnostics; resolution 11/12 bits, 40-pole, removing and inserting possible with active backplane bus
Product family SIPLUS S7-300 SM 332
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,328 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515139867
UPC 662643199000
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.01.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Load Voltage L+ (Without Load), Max. 340 Ma
From Backplane Bus 5 V Dc, Max. 100 Ma
Power Loss
Power Loss , Typ. 6 W
Analog Outputs
Number Of Analog Outputs 8; 4 @ +70 °C
Voltage Output, Short-Circuit Protection Yes
Voltage Output, Short-Circuit Current, Max. 25 Ma
Current Output, No-Load Voltage, Max. 18 V
Output Ranges, Voltage
0 To 10 V Yes
1 V To 5 V Yes
-10 V To +10 V Yes
Output Ranges, Current
0 To 20 Ma Yes
-20 Ma To +20 Ma Yes
4 Ma To 20 Ma Yes
Load Impedance (In Rated Range Of Output)
With Voltage Outputs, Min. 1 Kω
With Voltage Outputs, Capacitive Load, Max. 1 Μf
With Current Outputs, Max. 500 Ω
With Current Outputs, Inductive Load, Max. 10 Mh
Cable Length
Shielded, Max. 200 M
Analog Value Generation For The Outputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 12 Bit; ±10 V, ±20 Ma, 4 Ma To 20 Ma, 1 V To 5 V: 11 Bit + Sign; 0 V To 10 V, 0
Ma To 20 Ma: 12 Bit
Conversion Time (Per Channel) 0.8 Ms
Settling Time
For Resistive Load 0.2 Ms
For Capacitive Load 3.3 Ms
For Inductive Load 0.5 Ms; 0.5 Ms (1 Mh); 3.3 Ms (10 Mh)
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Output Range, (+/-) 0.5 %; ±0.6 % @ < 0 °C Or > 60 °C
Current, Relative To Output Range, (+/-) 0.6 %; ±0.7 % @ < 0 °C Or > 60 °C
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Output Range, (+/-) 0.4 %
Current, Relative To Output Range, (+/-) 0.5 %
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes
Diagnostics Indication Led
Group Error Sf (Red) Yes
Potential Separation
Potential Separation Analog Outputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Isolation Tested With 500 V Dc
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes; File E239877
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Railway Application
En 50121-4 No
En 50155 No

Ambient Temperature During Operation

Min. -25 °C
Max. 70 °C; = Tmax; 60 °C @ Ul/Cul, Atex And Fm Use
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En Yes; Class 6S3 Incl. Sand, Dust; *
60721-3-6
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 40-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 272 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible