This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1336-4GE00-2AB0

6AG1336-4GE00-2AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1336-4GE00-2AB0 Siemens

6AG1336-4GE00-2AB0 Siemens - SIPLUS S7-300 SM 336 F 6AI 15 Bit based on 6ES7336-4GE00-0AB0 with conformal coating, -25…+60 °C, 70° with forced convection, fail-safe analog inputs for SIMATIC Safety, with HART support, up to category 4 (EN 954-1) /SIL3 (IEC 61508)/ PLE (ISO 13849), 1x 20-pole

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£2,111.26 Exc. VAT
£2,533.51 Inc. VAT

Product

Article Number (Market Facing Number) 6AG1336-4GE00-2AB0
Product Description SIPLUS S7-300 SM 336 F 6AI 15 Bit based on 6ES7336-4GE00-0AB0 with conformal coating, -25…+60 °C, 70° with forced convection, fail-safe analog inputs for SIMATIC Safety, with HART support, up to category 4 (EN 954-1) /SIL3 (IEC 61508)/ PLE (ISO 13849), 1x 20-pole
Product family SIPLUS SM 336 F-analog input module - Safety Integrated
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,357 Kg
Packaging Dimension 15,00 x 13,00 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618066505
UPC 804766226243
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group X0SM
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 10.10.2008
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V; ±5 %
Reverse Polarity Protection Yes
Input Current
From Power Supply L+, Typ. 150 Ma
From Backplane Bus 5 V Dc, Max. 90 Ma
Power Loss
Power Loss , Typ. 4.5 W

Analog Inputs

Number Of Analog Inputs 6
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Input Ranges
Voltage No
Current Yes
Thermocouple No
Resistance Thermometer No
Resistance No
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 150 Ω; Typ. 150 Ohms Max. 175 Ohms
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 150 Ω; Typ. 150 Ohms Max. 175 Ohms
Cable Length
Shielded, Max. 1 000 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit; 15 Bit + Sign
Integration Time (Ms) 20 Ms @ 50 Hz, 16.7 Ms @ 60 Hz
Interference Voltage Suppression For Interference
Frequency F1 In Hzf=N X (F1 ±0.5 %)
Encoder
Connection Of Signal Encoders
For Current Measurement As 2-Wire Transducer Yes
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Current, Relative To Input Range, (+/-) 0.3 %; 60 Μa
Basic Error Limit (Operational Limit At 25 °C)
Current, Relative To Input Range, (+/-) 0.1 %; 20 Μa
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Diagnostic Information Readable Yes
Diagnostics Indication Led
Fail-Safe Operation Yes
Group Error Sf (Red) Yes
Encoder Supply Vs (Green) No
Potential Separation
Potential Separation Analog Inputs
Between The Channels Yes
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Isolation Tested With 370V For 1 Min
Standards, Approvals, Certificates
Ce Mark Yes
Highest Safety Class Achievable In Safety Mode
Acc. To En 954 4
Performance Level According To Iso 13849-1 E
Sil Acc. To Iec 61508 Sil 3

Ambient Temperature During Operation

Min. -25 °C; = Tmin; Startup @ -25 °C
Max. 60 °C; = T Max; *+70 °C When Forced Convection At A Minimum Air Speed Of 0.3
M/S Through The Modules Is Ensured. If In The Course Of Maintenance Or
Automatic Diagnosis It Is Determined That The Admissible Specified Parameters
Have Been Exceeded, The Modules Should Be Subjected To A Proof Test (Function
Check) By The Manufacturer.
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation/Frost (No Commissioning Under Condensation
Conditions)
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 350 G

Documentation

Looking for a specific part?