Description for 6AG1414-3EM07-7AB0 Siemens

6AG1414-3EM07-7AB0 Siemens - SIPLUS S7-400 CPU 414-3 PN/DP -25 ... +70°C with conformal coating based on 6ES7414-3EM07-0AB0 . Central processing unit with: Work memory 4 MB, (2 MB code, 2 MB data), Interfaces 1st interface MPI/DP 12 Mbit/s, (X1), 2nd interface ETHERNET/PROFINET (X5) 3rd interface IF 964-DP plug-in (IF1)

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1414-3EM07-7AB0
Product Description SIPLUS S7-400 CPU 414-3 PN/DP based on 6ES7414-3EM07-0AB0 with conformal coating, -25…+70 °C, central processing unit with: work memory 4 MB, (2 MB code, 2 MB data), interfaces 1st interface MPI/DP 12 Mbps, (X1), 2nd interface ETHERNET/PROFINET (X5) 3rd interface IF 964-DP plug-in (IF1)
Product family SIPLUS S7-400 CPU 414
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 1,159 Kg
Packaging Dimension 23,00 x 30,00 x 6,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618073138
UPC 804766532832
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4656
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 10.08.2016
Product class D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes; Via Profibus Dp Or Profinet Interface
Engineering With
Programming Package Step 7 V5.5 Or Higher With Hsp 262
Cir - Configuration In Run
Cir Synchronization Time, Basic Load 100 Ms
Cir Synchronization Time, Time Per I/O Byte 15 Μs

Supply Voltage

Rated Value (Dc) Power Supply Via System Power Supply
Input Current
From Backplane Bus 5 V Dc, Typ. 1.3 A
From Backplane Bus 5 V Dc, Max. 1.6 A
From Backplane Bus 24 V Dc, Max. 300 Ma; 150 Ma Per Dp Interface
From Interface 5 V Dc, Max. 90 Ma; At Each Dp Interface
Power Loss
Power Loss , Typ. 6.5 W
Memory
Type Of Memory Ram
Work Memory
Integrated 4 Mbyte
Integrated (For Program) 2 Mbyte
Integrated (For Data) 2 Mbyte
Expandable No
Load Memory
Expandable Feprom Yes; With Memory Card (Flash)
Expandable Feprom, Max. 64 Mbyte
Integrated Ram, Max. 512 Kbyte
Expandable Ram Yes; With Memory Card (Ram)
Expandable Ram, Max. 64 Mbyte
Backup
Present Yes
With Battery Yes; All Data
Without Battery No
Battery
Backup Battery
Backup Current, Typ. 180 Μa; Up To 40 °C
Backup Current, Max. 850 Μa
Backup Time, Max. Dealt With In The Module Data Manual With The Secondary Conditions And The
Factors Of Influence
Feeding Of External Backup Voltage To Cpu 5 V Dc To 15 V Dc
Cpu Processing Times
For Bit Operations, Typ. 18.75 Ns
For Word Operations, Typ. 18.75 Ns
For Fixed Point Arithmetic, Typ. 18.75 Ns
For Floating Point Arithmetic, Typ. 37.5 Ns
Cpu-Blocks
Db
Number, Max. 6 000; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 3 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 3 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 4; Ob 10-13
Number Of Delay Alarm Obs 4; Ob 20-23
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35 (Shortest Cycle That Can Be Set = 500 Μs)
Number Of Process Alarm Obs 4; Ob 40-43
Number Of Dpv1 Alarm Obs 3; Ob 55-57
Number Of Isochronous Mode Obs 3; Ob 61-63
Number Of Multicomputing Obs 1; Ob 60
Number Of Background Obs 1; Ob 90
Number Of Startup Obs 3; Ob 100-102
Number Of Asynchronous Error Obs 9; Ob 80-88
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 24
Additional Within An Error Ob 1
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
— Preset No Times Retentive
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. Total Working And Load Memory (With Backup Battery)
Flag
Size, Max. 8 Kbyte; Size Of Bit Memory Address Area
Retentivity Available Yes
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; In 1 Memory Byte
Local Data
Adjustable, Max. 16 Kbyte
Preset 8 Kbyte
Address Area
I/O Address Area
Inputs 8 Kbyte
Outputs 8 Kbyte
Process Image
Inputs, Adjustable 8 Kbyte
Outputs, Adjustable 8 Kbyte
Inputs, Default 256 Byte
Outputs, Default 256 Byte
Consistent Data, Max. 244 Byte
Access To Consistent Data In Process Image Yes
Subprocess Images
Number Of Subprocess Images, Max. 15
Digital Channels
Inputs 65 536
— Of Which Central 65 536
Outputs 65 536
— Of Which Central 65 536
Analog Channels
Inputs 4 096
— Of Which Central 4 096
Outputs 4 096
— Of Which Central 4 096
Hardware Configuration
Number Of Expansion Units, Max. 21
Connectable Ops 63
Multicomputing Yes; 4 Cpus Max. (With Ur1 Or Ur2)
Interface Modules
Number Of Connectable Ims (Total), Max. 6
Number Of Connectable Im 460S, Max. 6
Number Of Connectable Im 463S, Max. 4; Im 463-2
Number Of Dp Masters
Integrated 1
Via Cp 10; Cp 443-5 Extended
Via Im 467 4
Mixed Mode Im + Cp Permitted No; Im 467 Cannot Be Used Jointly With Cp 443-5 Ext. Or Cp 443-1 In
Profinet Io Mode
Via Interface Module 1; If 964-Dp
Number Of Pluggable S5 Modules (Via Adapter Capsule In
Central Device), Max.6
Number Of Io Controllers
Integrated 1
Via Cp 4; Max. 4 In The Central Controller; No Mixed Operation Of Different Cp 443-1
Types In Profinet Io Mode
Number Of Operable Fms And Cps (Recommended)
Fm Limited By Number Of Slots And Number Of Connections
Cp, Ptp Cp 440: Limited By Number Of Slots; Cp 441: Limited By Number Of Slots And
Number Of Connections
14; In Total Max. 10 Cps As Dp Master And Profinet Controller, Of Which Up Profibus And Ethernet Cps
To 10 Ims Or Cps As Dp Master And Up To 4 Cps As Profinet Controller
Slots
Required Slots 2
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Resolution 1 Ms
Deviation Per Day (Buffered), Max. 1.7 S; Power Off
Deviation Per Day (Unbuffered), Max. 8.6 S; For Power On
Operating Hours Counter
Number 16
Number/Number Range 0 To 15
Range Of Values Sfcs 2, 3 And 4: 0 To 32767 Hours Sfc 101: 0 To 2^31 - 1 Hours
Granularity 1 H
Retentive Yes
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp Yes; As Client
To If 964 Dp Yes
Time Difference In System When Synchronizing Via
Ethernet, Max. 10 Ms
Mpi, Max. 200 Ms
Interfaces
Interfaces/Bus Type 1 X Mpi/Profibus Dp, 1 X Profinet (2 Ports), 1 X Profibus Dp
(Optionally Pluggable)
Number Of Rs 485 Interfaces 1; Combined Mpi / Profibus Dp
Number Of Other Interfaces 1; Profibus Dp With If 964-Dp (Plug-In Option; Mlfb: 6Es7964-2Aa04-
0Ab0)
1. Interface
Interface Type Mpi/Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device Yes
Mpi
Number Of Connections 32; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
Profibus Dp Master
Number Of Connections, Max. 16; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32
Services
— Pg/Op Communication Yes
— Routing Yes; S7 Routing
— Global Data Communication No
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
1St Interface / Profibus Dp Device / Header
Number Of Connections 16
Gsd File Http://Support.Automation.Siemens.Com/Ww/View/En/113652
Transmission Rate, Max. 12 Mbit/S
Automatic Baud Rate Search No
Address Area, Max. 32; Virtual Slots
User Data Per Address Area, Max. 32 Byte
— Of Which Consistent, Max. 32 Byte
Services
— Pg/Op Communication Yes; With Interface Active
— Routing Yes; With Interface Active
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
2. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes; Autosensing
Autonegotiation Yes
Autocrossing Yes
Change Of Ip Address At Runtime, Supported Yes; Assignment By Higher-Level Io-Controller Or By The User Program With
Sfb104 "Ip_Conf"
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Profinet Cba Yes
Profibus Dp Master No
Profibus Dp Device No
Open Ie Communication Yes
Web Server Yes
Point-To-Point Connection No
Media Redundancy Yes
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S
Services
— Pg/Op Communication Yes
— S7 Communication Yes
— Isochronous Mode Yes; Only With Irt And The High Performance Option
— Shared Device Yes
— Prioritized Startup Yes
— Number Of Io Devices With Prioritized Startup, Max. 32
— Number Of Connectable Io Devices, Max. 256
— Of Which Io Devices With Irt, Max. 64
— Of Which In Line, Max. 64
— Number Of Io Devices With Irt And The Option "High
Flexibility"256
— Of Which In Line, Max. 61
— Number Of Connectable Io Devices For Rt, Max. 256
— Of Which In Line, Max. 256
— Activation/Deactivation Of Io Devices Yes
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Io Devices Changing During Operation (Partner
Ports), Supportedyes
— Number Of Io Devices Per Tool, Max. 8; 8 Parallel Calls Of The Sfc 12 "D_Act_Dp" Possible Per Line. Max. 32 Io
Devices Changing During Operation (Partner Ports) Are Supported
— Device Replacement Without Swap Medium Yes
— Send Cycles 250 Μ S, 500 Μs, 1 Ms, 2 Ms, 4 Ms Additionally With Irt With High Performance:
250 Μs To 4 Ms In 125 Μs Frame
— Updating Time 250 Μs To 512 Ms; Minimum Value Depends On Preset Communication Share For
Profinet Io, On The Number Of Io Devices And On The Amount Of Configured
User Data, See Profinet System Description
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
— User Data Consistency, Max. 1 024 Byte
Profinet Io Device
Services
— Pg/Op Communication Yes
— S7 Communication Yes
— Isochronous Mode No
— Irt Yes
— Prioritized Startup Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Transfer Memory
— Inputs, Max. 1 440 Byte; Per Io Controller With Shared Device
— Outputs, Max. 1 440 Byte; Per Io Controller With Shared Device
Submodules
— Number, Max. 64
— User Data Per Submodule, Max. 1 024 Byte
Profinet Cba
Acyclic Transmission Yes
Cyclic Transmission Yes
Open Ie Communication
Number Of Connections, Max. 62
Local Port Numbers Used At The System End 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534,
65535
Keep-Alive Function, Supported Yes
3. Interface
Interface Type Pluggable Interface Module (If)
Plug-In Interface Modules If 964-Dp (Mlfb: 6Es7964-2Aa04-0Ab0)
Isolated Yes
Automatic Detection Of Transmission Rate No
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi No
Profibus Dp Master Yes
Profibus Dp Device Yes
Profibus Dp Master
Number Of Connections, Max. 16
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 96
Services
— Pg/Op Communication Yes
— Routing Yes; S7 Routing
— Global Data Communication No
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv0 Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 6 Kbyte
— Outputs, Max. 6 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
3Rd Interface / Profibus Dp Device / Header
Number Of Possible Connections / At The 3Rd Interface / As
Dp Slave16
Gsd File Http://Support.Automation.Siemens.Com/Ww/View/En/113652
Transfer Rate / At The 3Rd Interface / As Dp Slave /
Maximum 12 Mbit/S
Automatic Baud Rate Search No
Address Area, Max. 32; Virtual Slots
Data Volume / At The 3Rd Interface / As Dp Slave / As User
Data Per Address Range / Maximum32 Byte
— Data Volume / At The 3Rd Interface / As Dp Slave / As
Consistent Reference Data Per Address Range /
Maximum 32 Byte
Services
— Pg/Op Communication Yes
— Routing Yes; With Interface Active
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
Protocols
Redundancy Mode
Media Redundancy
— Switchover Time On Line Break, Typ. 200 Ms
— Number Of Stations In The Ring, Max. 50
Simatic Communication
S7 Routing Yes
Open Ie Communication
Tcp/Ip Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 62
— Data Length, Max. 32 Kbyte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes; Via Integrated Profinet Interface Or Cp 443-1 Adv. And Loadable Fbs
— Number Of Connections, Max. 62
— Data Length, Max. 32 Kbyte; 1 452 Bytes Via Cp 443-1 Adv.
Udp Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 62
— Data Length, Max. 1 472 Byte
Web Server
Supported Yes
User-Defined Websites Yes
Number Of Http Clients 5
Isochronous Mode
Equidistance Yes
Number Of Dp Masters With Isochronous Mode 2
User Data Per Isochronous Slave, Max. 244 Byte
Shortest Clock Pulse 1 Ms; 0.5 Ms Without Use Of Sfc 126, 127
Max. Cycle 32 Ms
Communication Functions / Header
Pg/Op Communication Yes
Number Of Connectable Ops Without Message Processing 63
Number Of Connectable Ops With Message Processing 63; When Using Alarm_S/Sq And Alarm_D/Dq
Data Record Routing Yes
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 8
Number Of Gd Packets, Transmitter, Max. 8
Number Of Gd Packets, Receiver, Max. 16
Size Of Gd Packets, Max. 54 Byte
Size Of Gd Packet (Of Which Consistent), Max. 1 Variable
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 1 Variable
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. 64 Kbyte
User Data Per Job (Of Which Consistent), Max. 462 Byte; 1 Variable
S5 Compatible Communication
Supported Yes; Via Fc Ag_Send And Ag_Recv, Max. Via 10 Cp 443-1 Or 443-5
User Data Per Job, Max. 8 Kbyte
User Data Per Job (Of Which Consistent), Max. 240 Byte
Number Of Simultaneous Ag-Send/Ag-Recv Orders Per 24/24
Cpu, Max.
Standard Communication (Fms)
Supported Yes; Via Cp And Loadable Fb
Communication Functions / Profinet Cba (With Set Target Load) / Header
Setpoint For The Cpu Communication Load 20 %
Number Of Remote Interconnection Partners 32
Number Of Master/Device Functions 150
Total Of All Master/Device Connections 4 500
Data Length Of All Incoming Master/Device Connections,
Max.45 000 Byte
Data Length Of All Outgoing Master/Device Connections,
Max.45 000 Byte
Number Of Device-Internal And Profibus
Interconnections1 000
Data Length Of Device-Internal Und Profibus
Interconnections, Max.16 000 Byte
Data Length Per Connection, Max. 2 000 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Acyclic Transfer / Header
— Sampling Interval, Min. 200 Ms; Depending On Preset Communication Load, Number Of Interconnections
And Data Length Used
— Number Of Incoming Interconnections 250
— Number Of Outgoing Interconnections 250
— Data Length Of All Incoming Interconnections, Max. 8 000 Byte
— Data Length Of All Outgoing Interconnections, Max. 8 000 Byte
— Data Volume / As User Data For Remote
Interconnections / In The Case Of Acyclic Transmission /
With Profinet Cba / Per Connection / Maximum2 000 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Cyclic Transfer / Header
— Transmission Frequency: Transmission Interval, Min. 1 Ms; Depending On Preset Communication Load, Number Of Interconnections
And Data Length Used
— Number Of Incoming Interconnections 300
— Number Of Outgoing Interconnections 300
— Data Length Of All Incoming Interconnections, Max. 4 800 Byte
— Data Length Of All Outgoing Interconnections, Max. 4 800 Byte
— Data Volume / As User Data For Remote
Interconnections / With Cyclical Transfer / With
Profinet Cba / Per Connection / Maximum450 Byte
Performance Data / Profinet Cba / Hmi Variables Via Profinet / Acyclic / Header
— Number Of Stations That Can Log On For Hmi Variables
(Pn Opc/Imap)2X Pn Opc/1X Imap
— Hmi Variable Updating 500 Ms
— Number Of Hmi Variables 1 000
— Data Length Of All Hmi Variables, Max. 32 000 Byte
Performance Data / Profinet Cba / Profibus Proxy Functionality / Header
— Supported Yes; 32 Profibus Slaves Max. Connectable
— Data Length Per Connection, Max. 240 Byte; Slave-Dependent
Number Of Connections
Overall 64
Usable For Pg Communication 63
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Max. 0
Usable For Op Communication 63
— Reserved For Op Communication 1
— Adjustable For Op Communication, Max. 0
Usable For S7 Basic Communication 62
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Max. 0
Usable For S7 Communication 62
— Reserved For S7 Communication 0
— Adjustable For S7 Communication, Max. 0
Usable For Routing 31
— Reserved For Routing 0
— Adjustable For Routing, Max. 0
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 63; Max. 63 With Alarm_S/Sq And Alarm_D/Dq (Ops); Max. 8 With Alarm,
Alarm_8, Alarm_8P, Notify And Notify_8 (E.G. Wincc)
Symbol-Related Messages Yes
Scan Procedure Yes
Program Alarms Yes
Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 400; Simultaneously Active Alarm_S/Sq Blocks Or Alarm_D/Dq Blocks
Alarm 8-Blocks Yes
Number Of Instances For Alarm 8 And S7 Communication
Blocks, Max.1 200
Preset, Max. 300
Process Control Messages Yes
Number Of Archives That Can Log On Simultaneously (Sfb 37
Ar_Send)16
Number Of Messages
Overall, Max. 512
In 100 Ms Grid, Max. 128
In 500 Ms Grid, Max. 256
In 1000 Ms Grid, Max. 512
Number Of Additional Values
With 100 Ms Grid, Max. 1
With 500, 1000 Ms Grid, Max. 10
Test Commissioning Functions
Status Block Yes; Up To 16 Simultaneously
Single Step Yes
Number Of Breakpoints 16
Status/Control
Status/Control Variable Yes; Up To 16 Variable Tables
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max. 70; Status/Control
Forcing
Forcing Yes
Forcing, Variables Inputs/Outputs, Bit Memories, Distributed I/Os
Number Of Variables, Max. 256
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Adjustable Yes
Preset 120
Service Data
Can Be Read Out Yes
Standards, Approvals, Certificates
Ce Mark Yes
Eac (Formerly Gost-R) Yes

Ambient Temperature During Operation

Min. -25 °C; = Tmin
Max. 70 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M) // Tmin ... (Tmax
- 10 K) At 795 Hpa ... 658 Hpa (+2 000 M ... +3 500 M) // Tmin ... (Tmax -20 K)
At 658 Hpa ... 540 Hpa (+3 500 M ... +5 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Resistance
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En Yes; Class 3S4 Incl. Sand, Dust, *
60721-3-3
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold And Fungal Spores (Excluding Fauna); Class 6B3 On
Request
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A
Configuration / Header
Configuration Software
Step 7 Yes
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 7
Access To Consistent Data In Process Image Yes
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Configuration / Programming / Number Of Simultaneously Active Sfc / Header
— Dpsyc_Fr 2; Sfc 11; Per Interface
— D_Act_Dp 8; Sfc 12; Per Interface
— Rd_Rec 8; Sfc 59; Per Interface
— Wr_Rec 8; Sfc 58; Per Interface
— Wr_Parm 8; Sfc 55; Per Interface
— Parm_Mod 1; Sfc 57; Per Interface
— Wr_Dparm 2; Sfc 56; Per Interface
— Dpnrm_Dg 8; Sfc 13; Per Interface
— Rdsysst 8; Sfc 51
— Dp_Topol 1; Sfc 103; Per Interface
Configuration / Programming / Number Of Simultaneously Active Sfb / Header
— Rdrec 8; Sfb 52; Per Interface, But Not More Than 32 Across All External Interfaces
— Wrrec 8; Sfb 53; Per Interface, But Not More Than 32 Across All External Interfaces
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy

Dimensions

Width 50 Mm
Height 290 Mm
Depth 219 Mm
Weight S
Weight , Approx. 900 G