This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1677-2SB42-2GB0

6AG1677-2SB42-2GB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1677-2SB42-2GB0 Siemens

6AG1677-2SB42-2GB0 Siemens - SIPLUS ET 200SP CPU 1515SP PC2 F based on 6ES7677-2SB42-0GB0 with conformal coating, -40…+60 °C, 8 GB RAM, 128 GB CFast with Windows 10 IoT Enterprise 64-bit and S7-1500 Software Controller CPU 1505SP F preinstalled, interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet 2x USB 3.0; 2x USB 2.0, 1x DisplayPort, documentation on USB flash drive, restore USB flash drive

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1677-2SB42-2GB0
Product Description SIPLUS ET 200SP CPU 1515SP PC2 F based on 6ES7677-2SB42-0GB0 with conformal coating, -40…+60 °C, 8 GB RAM, 128 GB CFast with Windows 10 IoT Enterprise 64-bit and S7-1500 Software Controller CPU 1505SP F preinstalled, interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet 2x USB 3.0; 2x USB 2.0, 1x DisplayPort, documentation on USB flash drive, restore USB flash drive
Product family SIPLUS CPU 1515SP PC2 F
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 1,058 Kg
Packaging Dimension 14,00 x 18,50 x 9,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618100926
UPC 195125269606
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4257
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 18.09.2018
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Input Current
Current Consumption (Rated Value) 1.8 A; Full Processor Load, Incl. Et 200Sp Modules And Using Usb
Current Consumption (In No-Load Operation), Typ. 0.5 A
Current Consumption, Max. 2.9 A
I²T 0.426 A²·S; With Starting Current Inrush
Power
Active Power Input, Max. 43 W; Incl. Et 200Sp Modules And Using Usb
Infeed Power To The Backplane Bus 8.75 W
Power Loss
Power Loss , Typ. 16 W
Processor
Processor Type Intel Atom E3940, 1.6 Ghz, 4 Cores
Memory
Type Of Memory Ddr3L
Main Memory 8 Gb Ram
Cfast Memory Card Yes; 30 Gb Flash Memory
Simatic Memory Card Required No
Work Memory
Integrated (For Program) 1.5 Mbyte
Integrated (For Data) 5 Mbyte
Integrated (For Cpu Function Library Of Cpu Runtime) 20 Mbyte
Load Memory
Integrated (On Pc Mass Storage) 320 Mbyte
Backup
With Ups Yes; All Memory Areas Declared Retentive
With Non-Volatile Memory Yes
Cpu Processing Times
For Bit Operations, Typ. 10 Ns
For Word Operations, Typ. 12 Ns
For Fixed Point Arithmetic, Typ. 16 Ns
For Floating Point Arithmetic, Typ. 64 Ns
Cpu-Blocks
Number Of Elements (Total) 6 000; In Addition To Blocks Such As Dbs, Fbs And Fcs, Udts, Global
Constants, Etc. Are Also Regarded As Elements
Db
Number, Max. 5 999; Number Range: 1 To 65535
Size, Max. 5 Mbyte
Fb
Number, Max. 5 998; Number Range: 1 To 65535
Size, Max. 1 024 Kbyte
Fc
Number, Max. 5 999; Number Range: 1 To 65535
Size, Max. 1 024 Kbyte
Ob
Size, Max. 1 024 Kbyte
Number Of Free Cycle Obs 100
Number Of Time Alarm Obs 20
Number Of Delay Alarm Obs 20
Number Of Cyclic Interrupt Obs 20
Number Of Process Alarm Obs 50
Number Of Dpv1 Alarm Obs 3
Number Of Isochronous Mode Obs 1
Number Of Technology Synchronous Alarm Obs 2
Number Of Startup Obs 100
Number Of Asynchronous Error Obs 4
Number Of Synchronous Error Obs 2
Number Of Diagnostic Alarm Obs 1
Nesting Depth
Per Priority Class 24; Up To 8 Possible For F-Blocks
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
Iec Counter
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
Iec Timer
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 410 Kbyte; For Storage In Nvram; For Storage In Mass Storage 5 242 020 Bytes
Flag
Size, Max. 16 Kbyte
Number Of Clock Memories 8; 8 Clock Memory Bit, Grouped Into One Clock Memory Byte
Data Blocks
Retentivity Adjustable Yes
Retentivity Preset No
Local Data
Per Priority Class, Max. 64 Kbyte; Max. 16 Kb Per Block
Address Area
Number Of Io Modules 8 192
I/O Address Area
Inputs 32 Kbyte; All Inputs Are In The Process Image
Outputs 32 Kbyte; All Outputs Are In The Process Image
Subprocess Images
Number Of Subprocess Images, Max. 32
Hardware Configuration
Integrated Power Supply Yes
Number Of Distributed Io Systems 20
Number Of Dp Masters
Via Cm 1
Number Of Io Controllers
Via Pc Interfaces 1
Rack
Modules Per Rack, Max. 64; Cpu 1515Sp Pc + 64 Modules + Server Module
Number Of Lines, Max. 1
Ptp Cm
Number Of Ptp Cms The Number Of Connectable Ptp Cms Is Only Limited By The Number Of Available
Slots
Time Of Day
Clock
Type Hardware Clock
Hardware Clock (Real-Time) Yes; Resolution: 1 S
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Clock Synchronization
Supported Yes
To Dp, Master Yes
On Ethernet Via Ntp Yes
On Windows Clock, Device Yes
Interfaces
Number Of Industrial Ethernet Interfaces 2
Number Of Profinet Interfaces 1
Number Of Profibus Interfaces 1; Via Cm Dp Module
Number Of Rs 485 Interfaces 1; Via Cm Dp Module
Number Of Usb Interfaces 4; 2X Usb 2.0, 2X Usb 3.0 On Front Side
Number Of Sd Card Slots 1
Video Interfaces
Graphics Interface 1X Displayport
1. Interface
Interface Type Profinet
Automatic Detection Of Transmission Rate Yes
Autonegotiation Yes
Autocrossing Yes
Number Of Connections 88
Interface Types
Rj 45 (Ethernet) Yes; Via Busadapter Ba 2X Rj45
— Transmission Rate, Max. 100 Mbit/S
— Industrial Ethernet Status Led Yes
Number Of Ports 2
Integrated Switch Yes
Busadapter (Profinet) Yes; Compatible Busadapter: Ba 2X Rj45, Ba 2X Fc, Ba 2X Scrj (From Fs03,
V2.2), Ba Scrj / Rj45 (From Fs03, V3.1), Ba Scrj / Fc (From Fs03, V3.1),
Ba 2X Lc (From Fs03, V3.3), Ba Lc / Rj45 (From Fs03, V3.3), Ba Lc / Fc
(From Fs03, V3.3)
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes
Web Server Yes
Profinet Io Controller
Services
— Isochronous Mode Yes
— Shortest Clock Pulse 500 Μs
— Irt Yes
— Profienergy Yes
— Prioritized Startup Yes; Max. 32 Profinet Devices; If You Want To Use The "Prioritized Startup"
Functionality In Step 7 For The Profinet Interface Of The Cpu, The Cpu And
The Device Must Be Separated By Means Of A Switch (E.G. Scalance X205)
— Number Of Connectable Io Devices, Max. 128
— Of Which Io Devices With Irt, Max. 64
— Of Which In Line, Max. 64
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Io Devices Changing During Operation (Partner
Ports), Supportedyes
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
Update Time For Irt
— For Send Cycle Of 500 Μs 500 Μs To 8 Ms
— For Send Cycle Of 1 Ms 1 Ms To 16 Ms
— For Send Cycle Of 2 Ms 2 Ms To 32 Ms
— For Send Cycle Of 4 Ms 4 Ms To 64 Ms
— With Irt And Parameterization Of "Odd" Send Cycles Update Time = Set "Odd" Send Clock (Any Multiple Of 125 Μs: 375 Μs, 625 Μs ... 3
875 Μs)
Update Time For Rt
— For Send Cycle Of 500 Μs 500 Μs To 256 Ms
— For Send Cycle Of 1 Ms 1 Ms To 512 Ms
— For Send Cycle Of 2 Ms 2 Ms To 512 Ms
— For Send Cycle Of 4 Ms 4 Ms To 512 Ms
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
Profinet Io Device
Services
— Isochronous Mode No
— Shortest Clock Pulse 500 Μs
— Irt Yes
— Profienergy Yes
— Prioritized Startup Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
— Asset Management Record Yes
2. Interface
Interface Type Integrated Ethernet Interface
Automatic Detection Of Transmission Rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface Types
Rj 45 (Ethernet) Yes; Integrated
— Transmission Rate, Max. 1 000 Mbit/S
— Industrial Ethernet Status Led No
Number Of Ports 1
3. Interface
Interface Type Profibus With Cm Dp
Number Of Connections 44
Interface Types
Rs 485 Yes
Protocols
Profibus Dp Master Yes
Profibus Dp Device Yes
Simatic Communication Yes
Profibus Dp Master
Max. Number Of Dp Devices 125
Services
— Equidistance No
— Isochronous Mode No
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
Interface Types
Rs 485
Transmission Rate, Max. 12 Mbit/S
Protocols
Profisafe Yes
Number Of Connections
Number Of Connections, Max. 88
Number Of Connections Reserved For Es/Hmi/Web 10
Number Of S7 Routing Paths 16
Redundancy Mode
Media Redundancy
— Mrp Yes
— Mrpd Yes
— Switchover Time On Line Break, Typ. 200 Ms
— Number Of Stations In The Ring, Max. 50
Simatic Communication
Pg/Op Communication Yes
S7 Routing Yes
S7 Communication, As Server Yes
S7 Communication, As Client Yes
User Data Per Job, Max. 64 Kbyte; Bsend/Brcv: 64 Kb; Put/Get: 960 Bytes
Open Ie Communication
Tcp/Ip Yes
— Data Length, Max. 64 Kbyte
Iso-On-Tcp (Rfc1006) Yes
— Data Length, Max. 64 Kbyte
Udp Yes
— Data Length, Max. 1 472 Kbyte
Snmp Yes
Dcp Yes
Lldp Yes
Web Server
Http Yes; Via Windows And Profinet Interface
Https Yes; Via Windows And Profinet Interface
Opc Ua
Runtime License Required Yes; "Small" License Required
Opc Ua Client Yes; From Sw Cpu 1505Sp V2.6
Opc Ua Server Yes; Data Access (Read, Write, Subscribe), Runtime License Required
— Application Authentication Yes; Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— Security Policies Yes; Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User Authentication Yes; "Anonymous" Or By User Name & Password
Further Protocols
Modbus Yes; Modbus Tcp
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 32
Program Alarms Yes
Number Of Configurable Program Messages, Max. 10 000
Number Of Simultaneously Active Program Alarms 1 000
Number Of Program Alarms 1 000
Number Of Alarms For System Diagnostics 200
Number Of Alarms For Motion Technology Objects 160
Test Commissioning Functions
Joint Commission (Team Engineering) Yes; Parallel Online Access Possible For Up To 8 Engineering Systems
Status Block Yes; Up To 8 Simultaneously
Single Step No
Number Of Breakpoints 8
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max.
— Of Which Status Variables, Max. 200
— Of Which Control Variables, Max. 200
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 200
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 1 000
— Of Which Powerfail-Proof 300
Traces
Number Of Configurable Traces 4
Memory Size Per Trace, Max. 512 Kbyte
Interrupts/Diagnostics/Status Information
Diagnostics Indication Led
Run/Stop Led Yes
Error Led Yes
Maint Led Yes
Supported Technology Objects
Motion Control Yes
Number Of Available Motion Control Resources For
Technology Objects2 400
Required Motion Control Resources
— Per Speed-Controlled Axis 40; Per Axis
— Per Positioning Axis 80; Per Axis
— Per Synchronous Axis 160; Per Axis
— Per External Encoder 80; Per External Encoder
— Per Output Cam 20; Per Cam
— Per Cam Track 160; Per Cam Track
— Per Probe 40; Per Probe
Positioning Axis
— Number Of Positioning Axes At Motion Control Cycle
Of 4 Ms (Typical Value)15
— Number Of Positioning Axes At Motion Control Cycle
Of 8 Ms (Typical Value)30
Control Ler
Pid_Compact Yes; Universal Pid Controller With Integrated Optimization
Pid_3Step Yes; Pid Controller With Integrated Optimization For Valves
Pid-Temp Yes; Pid Controller With Integrated Optimization For Temperature
Counting And Measuring
High-Speed Counter Yes
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 432 Kg
— Global Warming Potential, (During Production) [Co2
Eq]73.8 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]365 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-6.71 Kg
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 3
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 2.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 1.00E-09 1/H

Ambient Temperature During Operation

Min. -40 °C; = Tmin
Max. Up To 60 °C With Max. 32 Et 200Sp Modules; Up To 55 °C With Max. 64 Et
200Sp Modules
Horizontal Installation, Min. -40 °C; = Tmin (Incl. Condensation/Frost)
Horizontal Installation, Max. 60 °C; = Tmax
Vertical Installation, Min. -40 °C; = Tmin
Vertical Installation, Max. 50 °C; = Tmax; With Max. 32 Et 200Sp Modules
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Vibrations
Operation, Tested According To Iec 60068-2-6 Yes
Transport, Tested Acc. To Iec 60068-2-6 Yes
Shock Testing
Tested According To Iec 60068-2-6 Yes
Tested According To Iec 60068-2-27 Yes
Tested According To Iec 60068-2-29 Yes
Storage/Transport, Tested Acc. To Iec 60068-2-27 Yes
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-3Yes; Class 3M8 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0)
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold, Fungal And Dry Rot Spores (Excluding Fauna)
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-6Yes; Class 6M4 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0)
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A

Operating Systems

Pre-Installed Operating System Windows 10 Iot Enterprise 2016 Ltsb, 64Bit, Mui
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes; Incl. Failsafe
— Fbd Yes; Incl. Failsafe
— Stl Yes
— Scl Yes
— Cfc No
— Graph Yes
Know-How Protection
User Program Protection/Password Protection Yes
Copy Protection Yes
Block Protection Yes
Access Protection
Protection Level: Write Protection Yes
Protection Level: Read/Write Protection Yes
Protection Level: Complete Protection Yes
Programming / Cycle Time Monitoring / Header
Lower Limit Adjustable Minimum Cycle Time
Upper Limit Adjustable Maximum Cycle Time
Open Development Interfaces
Size Of Odk So File, Max. 5.8 Mbyte
Peripherals/Options
Sd Card Optionally For Additional Mass Storage

Dimensions

Width 160 Mm
Height 117 Mm
Depth 75 Mm
Weight S
Weight , Approx. 0.83 Kg

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible