This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG1688-3AF37-2AX0

6AG1688-3AF37-2AX0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG1688-3AF37-2AX0 Siemens

6AG1688-3AF37-2AX0 Siemens - SIPLUS HMI KP8F PN based on 6AV3688-3AF37-0AX0 with conformal coating, -20...+55 °C, Key Panel, 8 short-stroke switches with multi-colored LEDs, PROFINET interfaces with PROFIsafe, 8 DI/DO and 2 safety DI pins, 24 V DC can be looped through parameterizable as of STEP 7 V5.5

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG1688-3AF37-2AX0
Product Description SIPLUS HMI KP8F PN based on 6AV3688-3AF37-0AX0 with conformal coating, -20...+55 °C, Key Panel, 8 short-stroke switches with multi-colored LEDs, PROFINET interfaces with PROFIsafe, 8 DI/DO and 2 safety DI pins, 24 V DC can be looped through parameterizable as of STEP 7 V5.5
Product family SIPLUS HMI KP8/KP8F/KP32F
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,368 Kg
Packaging Dimension 10,50 x 18,00 x 6,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618092504
UPC 804766827891
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4574
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 10.11.2010
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Type Of Supply Voltage Dc
Rated Value (Dc) 24 V; 24 V Can Be Looped Through Connector, Interrupted When Pulled
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
Current Consumption (Rated Value) 0.3 A
Digital Inputs
Number Of Digital Inputs 8; Total Inputs And Outputs Max. 8 And 1X Sil 2 Or 2X Sil 3
Input Voltage
Rated Value (Dc) 24 V
Digital Outputs
Number Of Digital Outputs 8; Max. 8 Inputs And Outputs (Total)
Short-Circuit Protection Yes
Switching Capacity Of The Outputs
With Resistive Load, Max. 100 Ma
Output Voltage
Rated Value (Dc) 24 V; Non-Isolated
Total Current Of The Outputs
Current Per Channel, Max. 100 Ma
Current Per Group, Max. 800 Ma
Interfaces
Number Of Industrial Ethernet Interfaces 2; For The Construction Of Lines And Rings Without External Switch
Number Of Profinet Interfaces 2; Incl. Switch
Industrial Ethernet
Industrial Ethernet Status Led 2; Per Port
Number Of Ports Of The Integrated Switch 2; Per Port
Protocols
Profinet Yes; Also 3Rd Party Plc
Supports Protocol For Profinet Io Yes
Profinet Cba No
Irt Yes
Profisafe Yes; 1X Sil 3 (Two-Channel) Or 2X Sil 2 (Single-Channel) Emergency Stop
Sensors
Profibus No
Ethernet /Ip No
Mpi No
As-Interface No
Eib/Knx No
Protocols (Ethernet)
Tcp/Ip No
Redundancy Mode
Media Redundancy
— Mrp Yes
Further Protocols
As-Interface Safety At Work No
Can No
Data-Highway No
Devicenet No
Devicenet Safety No
Foundation Fieldbus No
Interbus No
Interbus-Safety No
Local Operating Network No
Modbus No
Safetybus P No
Sercos No
Suconet No
Other Bus Systems No
Test Commissioning Functions
Illuminant Test Yes; During Switch On
Key And Signal Lamp Test Yes; Automatically When Switching On
Emc
Emission Of Radio Interference Acc. To En 55 011
Limit Class A, For Use In Industrial Areas Yes; Group 1, Measured At A Distance Of 10 M
Limit Class B, For Use In Residential Areas No
Degree And Class Of Protection
Ip (At The Front) Ip65
Ip (Rear) Ip20
Nema (Front)
Enclosure Type 4 At The Front No
Enclosure Type 4X At The Front Yes; Incl. Nema12
Standards, Approvals, Certificates
Ce Mark Yes
Suitable For Safety Functions Yes
Marine Approval
Germanischer Lloyd (Gl) No
American Bureau Of Shipping (Abs) No
Bureau Veritas (Bv) No
Det Norske Veritas (Dnv) No
Lloyds Register Of Shipping (Lrs) No
Nippon Kaiji Kyokai (Class Nk) No
Polski Rejestr Statkow (Prs) No

Ambient Temperature During Operation

Min. -20 °C; = Tmin (Incl. Condensation/Frost)
Max. 55 °C; = Tmax
Operation (Vertical Installation)
— For Vertical Installation, Min. -20 °C
— For Vertical Installation, Max. 55 °C
Operation (Max. Tilt Angle)
— At Maximum Tilt Angle, Min. -20 °C
— At Maximum Tilt Angle, Max. 45 °C
Operation (Vertical Installation, Portrait Format)
— For Vertical Installation, Min. -20 °C
— For Vertical Installation, Max. 55 °C
Operation (Max. Tilt Angle, Portrait Format)
— At Maximum Tilt Angle, Min. -20 °C
— At Maximum Tilt Angle, Max. 45 °C
Ambient Temperature During Storage/Transportation
Min. -20 °C
Max. 60 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Ships/At Sea
— To Biologically Active Substances According To En
60721-3-6Yes; Class 6B2 Mold, Fungal And Dry Rot Spores (Excluding Fauna)
— To Chemically Active Substances According To En
60721-3-6Yes; Class 6C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-6Yes; Class 6S3 Incl. Sand, Dust; *
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating Yes; Conformal Coating, Class A
Compound For Printed Board Assemblies According To Ipc-
Cc-830A
Configuration / Header
Configuration Software
Step 7 Basic (Tia Portal) Yes
Step 7 Professional (Tia Portal) Yes
Functionality Under Wincc (Tia Portal)
Process Coupling
S7-1200 Yes; With Et 200Pro Cpu And Et 200S Cpu
S7-1500 Yes
S7-200 No
S7-300/400 Yes; With F-Cpu: Step 7 V11 Sp1 (Or Higher) And Safety V11 (Or Higher) Or
Simatic Step 7 Basic V11 (Or Higher)
Logo! No
Winac Yes
Sinumerik No
Simotion No
Allen Bradley (Ethernet/Ip) No
Allen Bradley (Df1) No
Mitsubishi (Mc Tcp/Ip) No
Mitsubishi (Fx) No
Omron (Fins Tcp) No
Omron (Link/Multilink) No
Modicon (Modbus Tcp/Ip) No
Modicon (Modbus) No
Mechanics/Material
Enclosure Material (Front)
Plastic Yes
Aluminum No
Stainless Steel No
Service Life
Short-Stroke Keys (In Switching Cycles) 1 500 000
Leds (On Period) 100 %

Dimensions

Width Of The Housing Front 98 Mm
Height Of Housing Front 155 Mm
Mounting Cutout, Width 68 Mm; Max. Thickness Of Mounting Plate 2 - 6 Mm
Mounting Cutout, Height 129 Mm
Overall Depth 49 Mm; Incl. Angled Simatic Ethernet Connector
Weight S
Weight (Without Packaging) 280 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible