This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG2136-6DB00-1CA0

6AG2136-6DB00-1CA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG2136-6DB00-1CA0 Siemens

6AG2136-6DB00-1CA0 Siemens - SIPLUS ET 200SP F-DQ 4x24VDC/2A PM rail based on 6ES7136-6DB00-0CA0 with conformal coating, -30…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), fail-safe digital outputs up to PL e (ISO 13849), up to SIL 3 (IEC 61508)

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£634.70 Exc. VAT
£761.64 Inc. VAT

Product

Article Number (Market Facing Number) 6AG2136-6DB00-1CA0
Product Description SIPLUS ET 200SP F-DQ 4x24VDC/2A PM rail based on 6ES7136-6DB00-0CA0 with conformal coating, -30…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), fail-safe digital outputs up to PL e (ISO 13849), up to SIL 3 (IEC 61508)
Product family SIPLUS extreme RAIL digital F-output modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,076 Kg
Packaging Dimension 6,50 x 8,80 x 3,80
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618070045
UPC 804766353253
Commodity Code 85389091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4C03
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 08.08.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version See Entry Id: 109746275

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Input Current
Current Consumption (Rated Value) 75 Ma; Without Load
Current Consumption, Max. 21 Ma; From The Backplane Bus
Output Voltage / Header
Rated Value (Dc) 24 V
Power
Power Available From The Backplane Bus 70 Mw
Power Loss
Power Loss , Typ. 4 W
Address Area
Address Space Per Module
Inputs 5 Byte
Outputs 5 Byte
Digital Outputs
Type Of Digital Output Transistor
Number Of Digital Outputs 4
Digital Outputs, Parameterizable Yes
Short-Circuit Protection Yes
Response Threshold, Typ. > 3.3 A
Open-Circuit Detection Yes
Response Threshold, Typ. 8 Ma
Overload Protection Yes
Response Threshold, Typ. 2.9 A
Limitation Of Inductive Shutdown Voltage To Typ. 2*47V
Control Ling A Digital Input Yes; Digital Output, According To Iec 61131-2, Type 2
Switching Capacity Of The Outputs
With Resistive Load, Max. 2 A
On Lamp Load, Max. 10 W
Load Resistance Range
Lower Limit 12 Ω
Upper Limit 2 000 Ω
Output Voltage
For Signal "1", Min. 24 V; L+ (-0.5 V)
Output Current
For Signal "1" Rated Value 2 A
For Signal "0" Residual Current, Max. 0.5 Ma
Switching Frequency
With Resistive Load, Max. 30 Hz; Symmetrical
With Inductive Load, Max. 0.1 Hz; According To Iec 60947-5-1, Dc-13, Symmetrical
On Lamp Load, Max. 10 Hz; Symmetrical
Total Current Of The Outputs
Current Per Channel, Max. 2 A; Note Derating Data In The Manual
Current Per Module, Max. 6 A; Note Derating Data In The Manual
Total Current Of The Outputs (Per Module)
Horizontal Installation
— Up To 40 °C, Max. 6 A; Note Derating Data In The Manual
— Up To 50 °C, Max. 5 A; Note Derating Data In The Manual
— Up To 60 °C, Max. 4 A; Note Derating Data In The Manual
— Up To 70 °C, Max. 4 A; Note Derating Information In The Manual; Only With Configured Slots To The
Left And Right Of The Module
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 500 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Substitute Values Connectable No
Alarms
Diagnostic Alarm Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Pwr Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Module Diagnostics Yes; Green/Red Diag Led
Potential Separation
Potential Separation Channels
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsno
Isolation
Isolation Tested With 750 V Dc (Type Test) And According To En 50155 (Routine Test)
Standards, Approvals, Certificates
Suitable For Safety Functions Yes
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 88.3 Kg
— Global Warming Potential, (During Production) [Co2
Eq]13.1 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]76.6 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-1.37 Kg
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 3
Sil In Accordance With En 50126, 50128, 50129 Sil 2; A Higher Safety Integrity Level Is Possible If Tested And Approved For The
Specific Application Under Consideration Of All Local Regulations.
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With
Sil2< 2.00E-04
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 2.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil2< 1.00E-08 1/H
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 1.00E-09 1/H
Railway Application
En 50121-3-2 Yes; Emc For Rail Vehicles
En 50121-4 Yes; Emc For Signal And Telecommunications Systems
En 50121-5 Yes; Emc For Fixed Installations And Railway Power Supply Equipment (Shielded
Cables Required)
En 50124-1 Yes; Railway Applications - Overvoltage Category Ov2; Pollution Degree Pd2;
Rated Surge Voltage Uni = 0.5 Kv; Unm = 24 V Dc
En 50125-1 Yes; Rail Vehicles - See Ambient Conditions
En 50125-2 Yes; Stationary Electrical Equipment - See Ambient Conditions
En 50125-3 Yes; Signal And Telecommunications Systems - See Ambient Conditions;
Vibrations And Shocks: Application Point Outside Of Tracks (1 M To 3 M Away
From Track)
En 50155 Yes; Rail Vehicles - Temperature Class Ot1, St1/St2, Horizontal Mounting
Position
En 61373 Yes; Rail Vehicles - Vibrations And Shocks: Category 1 Class A/B
Fire Protection Acc. To En 45545-2 Yes; For Proof Of Conformity, See Service & Support

Ambient Temperature During Operation

Horizontal Installation, Min. -30 °C; = Tmin (Incl. Condensation/Frost)
Horizontal Installation, Max. 60 °C; = Tmax; +70 °C For 10 Min (Ot1, St1/St2 Acc. To En 50155); +70 °C
Continuously With Configured Slots To The Left And Right Of The Module (Ot3, St0
Acc. To En 50155)
Vertical Installation, Min. -30 °C; = Tmin
Vertical Installation, Max. 50 °C; = Tmax
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-3Yes; Class 3M8 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0)
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-5Yes; Class 5M2 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0)
— Against Mechanical Environmental Conditions In
Agriculture Acc. To Iso 15003Yes; Level 1 (Location Le) Using The Siplus Mounting Kit Et 200Sp
(6Ag1193-6Aa00-0Aa0)
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Electronic Equipment On Rolling Stock Acc. To En 50155 Yes; Class Pc2 Protective Coating Acc. To En 50155:2017
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A

Dimensions

Width 15 Mm
Height 73 Mm
Depth 58 Mm
Weight S
Weight , Approx. 57 G
Other
Note: For Use In Railway Applications, Also Observe The Product Information "Siplus
Extreme Rail" A5E37661960A, Online Support Article 109736776

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible