Description for 6AG2212-1AE40-1XB0 Siemens

6AG2212-1AE40-1XB0 Siemens - SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL

Extended Description for 6AG2212-1AE40-1XB0 Siemens

6AG2212-1AE40-1XB0 Siemens - SIPLUS S7-1200 CPU 1212C DC/DC/DC T1 RAIL -25 ... +55°C T1 with 70°C for 10 min with conformal coating based on 6ES7212-1AE40-0XB0 . compact CPU. DC/DC/DC. Onboard I/O: 8 DI 24 V DC 6 DO 24 V DC 2 AI 0-10 V DC. Power supply: 20.4-28.8V DC Program/data memory 50 KB

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£683.12 Exc. VAT
£819.74 Inc. VAT

Product

Article Number (Market Facing Number) 6AG2212-1AE40-1XB0
Product Description SIPLUS S7-1200 CPU 1212C DC/DC/DC T1 rail based on 6ES7212-1AE40-0XB0 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), compact CPU, DC/DC/DC, onboard I/O: 8 DI 24 V DC 6 DQ 24 V DC 2 AI 0-10 V DC, power supply: 20.4-28.8 V DC program/data memory 50 KB
Product family SIPLUS S7-1200 CPU 1212C RAIL
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,340 Kg
Packaging Dimension 10,60 x 10,80 x 8,60
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618071134
UPC 804766903205
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4C02
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 12.12.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc)
24 V Dc Yes
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
Current Consumption (Rated Value) 400 Ma; Typical
Current Consumption, Max. 1 200 Ma; Cpu With All Expansion Modules
Inrush Current, Max. 12 A; At 28.8 V Dc
Output Current
For Backplane Bus (5 V Dc), Max. 890 Ma; Max. 5 V Dc For Sm And Cm
Encoder Supply
24 V Encoder Supply
24 V Permissible Range: 20.4V To 28.8V
Power Loss
Power Loss , Typ. 9 W
Memory
Work Memory
Integrated 50 Kbyte
Load Memory
Integrated 1 Mbyte
Plug-In (Simatic Memory Card), Max. 2 Gbyte; With Simatic Memory Card
Backup
Present Yes; Maintenance-Free
Without Battery Yes
Cpu Processing Times
For Bit Operations, Typ. 0.085 Μs; / Operation
For Word Operations, Typ. 1.7 Μs; / Operation
For Floating Point Arithmetic, Typ. 2.3 Μs; / Operation
Cpu-Blocks
Number Of Blocks (Total) Dbs, Fcs, Fbs, Counters And Timers. The Maximum Number Of Addressable
Blocks Ranges From 1 To 65535. There Is No Restriction, The Entire Working
Memory Can Be Used
Ob
Number, Max. Limited Only By Ram For Code
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 10 Kbyte
Flag
Size, Max. 4 Kbyte; Size Of Bit Memory Address Area
Address Area
I/O Address Area
Inputs 1 024 Byte
Outputs 1 024 Byte
Process Image
Inputs, Adjustable 1 Kbyte
Outputs, Adjustable 1 Kbyte
Hardware Configuration
Number Of Modules Per System, Max. 3 Comm. Modules, 1 Signal Board, 2 Signal Modules
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Backup Time 480 H; Typical
Deviation Per Day, Max. 60 S/Month At 25 °C
Digital Inputs
Number Of Digital Inputs 8; Integrated
Of Which Inputs Usable For Technological Functions 6; Hsc (High Speed Counting)
Source/Sink Input Yes
Number Of Simultaneously Controllable Inputs
All Mounting Positions
— Up To 40 °C, Max. 8
Input Voltage
Rated Value (Dc) 24 V
For Signal "0" 5 V Dc At 1 Ma
For Signal "1" 15 V Dc At 2.5 Ma
Input Current
For Signal "1", Typ. 1 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 Μ S; 0.05 / 0.1 / 0.2 / 0.4 /
0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 Ms
— At "0" To "1", Min. 0.1 Μs
— At "0" To "1", Max. 20 Ms
For Interrupt Inputs
— Parameterizable Yes
For Technological Functions
— Parameterizable Single Phase: 3 @ 100 Khz & 1 @ 30 Khz, Differential: 3 @ 80 Khz & 1 @ 30
Khz
Cable Length
Shielded, Max. 500 M; 50 M For Technological Functions
Unshielded, Max. 300 M; For Technological Functions: No
Digital Outputs
Number Of Digital Outputs 6
Of Which High-Speed Outputs 4; 100 Khz Pulse Train Output
Limitation Of Inductive Shutdown Voltage To L+ (-48 V)
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.5 A
On Lamp Load, Max. 5 W
Output Voltage
For Signal "0", Max. 0.1 V; With 10 Kohm Load
For Signal "1", Min. 20 V
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "0" Residual Current, Max. 0.1 Ma
Output Delay With Resistive Load
"0" To "1", Max. 1 Μs
"1" To "0", Max. 3 Μs
Switching Frequency
Of The Pulse Outputs, With Resistive Load, Max. 100 Khz
Relay Outputs
Number Of Relay Outputs 0
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 150 M

Analog Inputs

Number Of Analog Inputs 2
Input Ranges
Voltage Yes
Input Ranges (Rated Values), Voltages
0 To +10 V Yes
— Input Resistance (0 To 10 V) ≥100K Ohms
Cable Length
Shielded, Max. 100 M; Twisted And Shielded
Analog Outputs
Number Of Analog Outputs 0
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 10 Bit
Integration Time, Parameterizable Yes
Conversion Time (Per Channel) 625 Μs
Encoder
Connectable Encoders
2-Wire Sensor Yes
1. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface Types
Rj 45 (Ethernet) Yes
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Open Ie Communication Yes
Web Server Yes
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S
Services
— Number Of Connectable Io Devices, Max. 16
Profinet Io Device
Services
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Protocols
Supports Protocol For Profinet Io Yes
Profisafe No
Profibus Yes; Cm 1243-5 Required
As-Interface Yes
Protocols (Ethernet)
Tcp/Ip Yes
Open Ie Communication
Tcp/Ip Yes
Iso-On-Tcp (Rfc1006) Yes
Udp Yes
Web Server
Supported Yes
User-Defined Websites Yes
Further Protocols
Modbus Yes
Communication Functions / Header
S7 Communication
Supported Yes
As Server Yes
As Client Yes
Number Of Connections
Overall 16; Dynamically
Test Commissioning Functions
Status/Control
Status/Control Variable Yes
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Forcing
Forcing Yes
Diagnostic Buffer
Present Yes
Traces
Number Of Configurable Traces 2; Up To 512 Kb Of Data Per Trace Are Possible
Integrated Functions
Counter
Number Of Counters 4
Counting Frequency, Max. 100 Khz
Frequency Measurement Yes
Control Led Positioning Yes
Number Of Position-Controlled Positioning Axes, Max. 8
Number Of Positioning Axes Via Pulse-Direction Interface 4; With Integrated Do
Pid Controller Yes
Number Of Alarm Inputs 4
Number Of Pulse Outputs 4
Limit Frequency (Pulse) 100 Khz
Potential Separation
Potential Separation Digital Inputs
Potential Separation Digital Inputs 500 V Ac For 1 Minute
Between The Channels, In Groups Of 1
Potential Separation Digital Outputs
Potential Separation Digital Outputs Yes
Between The Channels No
Between The Channels, In Groups Of 1
Isolation
Isolation Tested With 750 V Dc (Type Test) And According To En 50155 (Routine Test)
Emc
Interference Immunity Against Discharge Of Static Electricity
Interference Immunity Against Discharge Of Static
Electricity Acc. To Iec 61000-4-2Yes
— Test Voltage At Air Discharge 8 Kv
— Test Voltage At Contact Discharge 6 Kv
Interference Immunity To Cable-Borne Interference
Interference Immunity On Supply Lines Acc. To Iec 61000-
4-4Yes
Interference Immunity On Signal Cables Acc. To Iec 61000-
4-4Yes
Interference Immunity Against Voltage Surge
Interference Immunity On Supply Lines Acc. To Iec 61000-
4-5Yes
Interference Immunity Against Conducted Variable Disturbance Induced By High-Frequency Fields
Interference Immunity Against High-Frequency Radiation Yes
Acc. To Iec 61000-4-6
Emission Of Radio Interference Acc. To En 55 011
Limit Class A, For Use In Industrial Areas Yes; Group 1
Limit Class B, For Use In Residential Areas Yes; When Appropriate Measures Are Used To Ensure Compliance With The Limits
For Class B According To En 55011
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 76.4 Kg
— Global Warming Potential, (During Production) [Co2
Eq]13.8 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]63.4 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.885 Kg
Railway Application
En 50121-3-2 Yes; Emc For Rail Vehicles
En 50121-4 Yes; Emc For Signal And Telecommunications Systems
En 50124-1 Yes; Railway Applications - Overvoltage Category Ov2; Pollution Degree Pd2;
Rated Surge Voltage Uni = 0.5 Kv; Unm = 24 V Dc
En 50125-1 Yes; Rail Vehicles - See Ambient Conditions
En 50125-2 Yes; Stationary Electrical Equipment - See Ambient Conditions
En 50125-3 Yes; Signal And Telecommunications Systems - See Ambient Conditions;
Vibrations And Shocks: Application Point Outside Of Tracks (1 M To 3 M Away
From Track)
En 50155 Yes; Rail Vehicles - Temperature Class Ot1, St1/St2, Horizontal Mounting
Position
En 61373 Yes; Rail Vehicles - Vibrations And Shocks: Category 1 Class A/B
Fire Protection Acc. To En 45545-2 Yes; For Proof Of Conformity, See Service & Support

Ambient Conditions

Free Fall
Fall Height, Max. 0.3 M; Five Times, In Product Package

Ambient Temperature During Operation

Horizontal Installation, Min. -25 °C; = Tmin (Incl. Condensation/Frost)
Horizontal Installation, Max. 60 °C; = Tmax; +70 °C For 10 Min (Ot1, St1/St2 Acc. To En 50155); Number Of
Simultaneously Switched On Inputs Or Outputs: 4 Or 3 (No Adjacent Points) At 60
°C Horizontal Or 50 °C Vertical, 8 Or 6 At 55 °C Horizontal Or 45 °C Vertical
Vertical Installation, Min. -25 °C; = Tmin
Vertical Installation, Max. 50 °C; = Tmax
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Vibrations
Vibration Resistance During Operation Acc. To Iec 60068-
2-62 G (M/S²) Wall Mounting, 1 G (M/S²) Din Rail
Operation, Tested According To Iec 60068-2-6 Yes
Shock Testing
Tested According To Iec 60068-2-27 Yes; Iec 68, Part 2-27 Half-Sine: Strength Of The Shock 15 G (Peak Value),
Duration 11 Ms
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Electronic Equipment On Rolling Stock Acc. To En 50155 Yes; Class Pc2 Protective Coating Acc. To En 50155:2017
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes
— Fbd Yes
— Scl Yes
Programming / Cycle Time Monitoring / Header
Adjustable Yes

Dimensions

Width 90 Mm
Height 100 Mm
Depth 75 Mm
Weight S
Weight , Approx. 370 G
Other
Note: For Use In Railway Applications, Also Observe The Product Information "Siplus
Extreme Rail" A5E37661960A, Online Support Article 109736776

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible