6AG25426VX004XE0 Siemens - SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL

Extended Description for 6AG25426VX004XE0 Siemens

6AG25426VX004XE0 Siemens - SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL -40...+70°C TX with 85°C for 10min with conformal coating based on 6GK7542-6VX00-0XE0 . for connection of an SIMATIC S7-ET 200SP to Industrial Ethernet. SINAUT ST7. TeleControl Server Basic. IEC-60870-5-104 or DNP3 protocol to a control center; Open IE communication (TCP/IP. ISO-on-TCP. UDP). IP broadcast/multicast. SNMPV1. DHCP. Secure e-Mail. IPV4/IPV6. support of SINEMA Remote Connect

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG2542-6VX00-4XE0
Product Description SIPLUS ET 200SP CP 1542SP-1 IRC TX rail based on 6GK7542-6VX00-0XE0 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), for connection of a SIMATIC S7-ET 200SP to Industrial Ethernet, SINAUT ST7, TeleControl Server Basic, IEC-60870-5-104 or DNP3 protocol to a control center; open IE communication (TCP/IP, ISO-on-TCP, UDP), IP broadcast/multicast, SNMPV1 DHCP, secure email, IPv4/IPv6, support of SINEMA Remote Connect
Product family SIPLUS extreme RAIL CP 1542SP-1 IRC
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,201 Kg
Packaging Dimension 1,00 x 1,00 x 1,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618098643
UPC 195125074613
Commodity Code 85176200
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4C03
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 27.02.2013
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Ambient Conditions

Ambient Temperature
For Vertical Installation / During Operation -40 ... +50 °C
For Horizontally Arranged Busbars / During Operation -40 ... +70 °C
During Storage -40 ... +70 °C
During Transport -40 ... +70 °C
Note +85 °C For 10 Min (Ot4, St1/St2 According To En 50155)
Installation Altitude / At Height Above Sea Level / Maximum 2000 M
Ambient Condition / Relating To Ambient Temperature - Air
Pressure - Installation Altitudetmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation / According To Iec 60068-2-38 /
Maximum 100 %; Rh Including Condensation/Frost (No Commissioning When Condensation
Is Present), Horizontal Installation
Chemical Resistance / To Commercially Available Cooling
Lubricantsyes; Incl. Airborne Diesel And Oil Droplets
Resistance To Biologically Active Substances
Conformity According To En 60721-3-3 Yes; Class 3B2 Mold And Fungal Spores (Excluding Fauna), Class 3B3 On
Request
Conformity According To En 60721-3-5 Yes; Class 5B2 Mold And Fungal Spores (Excluding Fauna), Class 5B3 On
Request
Resistance To Chemically Active Substances
Conformity According To En 60721-3-3 Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray In Accordance With En 60068-2-52
(Severity 3). The Supplied Plug Covers Must Remain In Place On The Unused
Interfaces During Operation.
Conformity According To En 60721-3-5 Yes; Class 5C3 (Rh < 75%) Including Salt Spray Acc. To En 60068-2-52
(Severity Level 3). The Supplied Plug Covers Must Remain In Place Over The
Unused Interfaces During Operation!
Resistance To Mechanically Active Substances
Conformity According To En 60721-3-3 Yes; Class 3S4 Incl. Sand, Dust. The Supplied Plug Covers Must Remain In Place
Over The Unused Interfaces During Operation.
Conformity According To En 60721-3-5 Yes; Class 5S3 Incl. Sand, Dust. The Supplied Plug Covers Must Remain In Place
Over The Unused Interfaces During Operation!
Coating / For Equipped Printed Circuit Board / According To En
61086Yes; Class 2 For High Availability
Type Of Coating / Protection Against Pollution According To En
60664-3Yes; Protection Of The Type 1
Type Of Coating / For Electronic Devices In Railway Applications
According To En 50155Yes; Protective Coating Of The Class Pc2 According To En 50155:2017
Type Of Test / Of The Coating / According To Mil-I-46058C Yes; Coating Discoloration During Service Life Possible
Product Conformity / Of The Coating / Qualification And
Performance Of Electrical Insulating Compound For Printed
Board Assemblies According To Ipc-Cc-830Ayes; Conformal Coating, Class A
Protection Class Ip Ip20
Design, Dimensions And Weights
Width 60 Mm
Height 117 Mm
Depth 74 Mm
Net Weight 0.18 Kg
Fastening Method
Product Features, S, Product Components / General

Product Features, Product Functions, Product Components / General

Number Of Units
Per Cpu / Maximum 2
Note 2 Cps Can Be Pluged In Per Cpu, Simultaneous Operation With Ba Send And
Cm Dp Is Possible
Performance Data / Open Communication
Number Of Possible Connections / For Open Communication
By Means Of T Blocks / Maximum 32
Data Volume
As User Data Per Iso On Tcp Connection / For Open
Communication / By Means Of T Blocks / Maximum65536 Byte
Performance Data / S7 Communication
Number Of Possible Connections / For S7 Communication
Maximum 16
With Op Connections / Maximum 16
Performance Data / Multi-Protocol Mode
Number Of Active Connections / With Multi-Protocol Mode 32
Performance Data / It Functions
Number Of Possible Connections
As Email Client / Maximum 1
Performance Data / Telecontrol
Suitability For Use
Node Station No
Substation Yes
Tim Control Center No
Control Center Connection Iec 60870-5, Dnp3, (Modbus Tcp By Block Solutions Of The Cpu) Capable
Control Stations, Connection To Tele Server Basic And St7 Capable
Control Station
By Means Of A Permanent Connection Supported
By Means Of Demand-Oriented Connection Supported
Note Connection To Scada System By Iec 60870-5 104, Dnp3, Telecontrol Server
Basic And St7 Capable Control Center
Protocol / Is Supported
Dnp3 Yes
Iec 60870-5 Yes
Sinaut St7 Protocol Yes
Product Function / Data Buffering If Connection Is Aborted Yes; Tcsb 64000 Events, Sinaut St7 32000 Telegrams, Dnp3 100000
Events, Iec 60870-5 100000 Events
Number Of Data Points Per Station / Maximum 500
Number Of Stations / For Direct Communication / With Telecontrol
Server Basic
In Send Direction / Maximum 3
In Receive Direction / Maximum 15
Product Functions / Management, Configuration, Engineering
Product Function / Mib Support Yes
Protocol / Is Supported
Snmp V1 Yes
Snmp V3 No
Dcp Yes
Lldp Yes
Configuration Software
Required Step 7 Professional V14 (Tia Portal) Or Higher
Identification & Maintenance Function
I&M0 - Device-Specific Information Yes
I&M1 - Higher Level Designation/Location Designation Yes
Product Functions / Diagnostics
Product Function / Web-Based Diagnostics Yes; Via Et 200Sp Cpu
Product Functions / Security
Product Function / With Vpn Connection Sinema Rc

Product Function

Blocking Of Communication Via Physical Ports Yes
Product Functions / Time
Product Function / Siclock Support Yes
Product Function / Pass On Time Synchronization Yes
Protocol / Is Supported
Ntp Yes
Ntp (Secure) No

Time Synchronization

From Ntp-Server Yes
From Control Center Yes
Product Functions / Position Detection
Certificate Of Suitability / Railway Application In Accordance With
En 50121-3-2Yes; Emc For Railway Vehicles
Certificate Of Suitability / Railway Application In Accordance With
En 50121-4Yes; Emc For Signal And Telecommunication Equipment
Certificate Of Suitability / Railway Application In Accordance With
En 50124-1Yes; Railway Applications - Overvoltage Category Ov2 Pollution Degree Pd2
Rated Impulse Voltage Uni = 0.5 Kvunm = Dc 24
Certificate Of Suitability / Railway Application In Accordance With
En 50125-1Yes; Railway Vehicles - See Ambient Conditions
Certificate Of Suitability / Railway Application In Accordance With
En 50125-2Yes; Fixed-Electrical Installations - See Ambient Conditions
Certificate Of Suitability / Railway Application In Accordance With
En 50125-3Yes; Signal And Telecommunications Equipment - See Ambient Conditions
Vibrations And Shocks: Application Point Outside The Rails (Distance 1 M To 3 M
From Rail)
Certificate Of Suitability / Railway Application In Accordance With
En 50155Yes; Railway Vehicles - Temperature Class Ot4, St1/St2, Horizontal Mounting
Position
Certificate Of Suitability / Railway Application In Accordance With
En 61373Yes; Railway Vehicles - Vibrations And Shocks Category 1 Class A/B
Certificate Of Suitability / Fire Protection In Accordance With En
45545-2Yes; Railway Vehicles - For Proof, See Service & Support

Standards, Specifications, Approvals

Reference Code
According To Iec 81346-2:2019 Kec

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible