This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG2623-0AA00-4AA0

6AG2623-0AA00-4AA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG2623-0AA00-4AA0 Siemens

6AG2623-0AA00-4AA0 Siemens - SIPLUS PN/J1939 link TX rail based on 6BK1623-0AA00-0AA0 with conformal coating, -40…+70 °C, ST1/2: +85 °C for 10 minutes, gateway from Profinet to J1939 networks, IP20

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG2623-0AA00-4AA0
Product Description SIPLUS PN/J1939 link TX rail based on 6BK1623-0AA00-0AA0 with conformal coating, -40…+70 °C, ST1/2: +85 °C for 10 minutes, gateway from Profinet to J1939 networks, IP20
Product family SIPLUS PN/J1939 LINK TX RAIL
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,272 Kg
Packaging Dimension 8,00 x 12,00 x 9,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618103705
UPC 195125017177
Commodity Code 85176200
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4C01
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 13.12.2017
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes
Isochronous Mode No
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version See Entry Id: 109746275
Installation Type/Mounting
Mounting Din Rail, Wall Mounting, Portrait Mounting
Mounting Position Any
Recommended Mounting Position Horizontal
Rail Mounting Yes
Control Cabinet Installation Yes

Supply Voltage

Type Of Supply Voltage Dc
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Overvoltage Protection Yes
Short-Circuit Protection Yes
Mains Buffering
Mains/Voltage Failure Stored Energy Time 10 Ms; Pn Side
Input Current
Current Consumption (Rated Value) 0.09 A
Current Consumption, Max. 0.11 A
Power Loss
Power Loss , Typ. 2.2 W
Interfaces
Interfaces/Bus Type 2X Ethernet (Rj45), 1X Sub-D (9-Pin)
Supports Protocol For Profinet Io
Automatic Detection Of Transmission Rate No
Transmission Rate, Max. 100 Mbit/S
Number Of Rj45 Ports 2
Number Of Fc (Fastconnect) Connections 2
Profinet Functions
Assignment Of The Ip Address, Supported Yes
Assignment Of The Device Name, Supported Yes
1. Interface
Interface Type J1939 According To The Standard "Sae J1939"
Isolated Yes; 500 V Ac Or 707 V Dc
Interface Types
Number Of Ports 1
Design Of The Connection 9-Pin Sub D Socket
Can
Can Operating Modes J1939 According To The Standard "Sae J1939"
Transmission Rate, Min. 100 Kbit/S
Transmission Rate, Max. 500 Kbit/S
Max. Number Of Devices 30
J1939
Addressable Ecus, Max. 30
Logical Nodes, Max. 253
Pdu 1 Yes
Pdu 2 Yes
Dm Data Yes
Bam Yes
Cmdt Yes
2. Interface
Interface Type Profinet
Isolated Yes; 1 500 V Ac Or 2 250 V Dc
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Device Yes
Interrupts/Diagnostics/Status Information
Status Indicator Yes
Alarms Yes
Diagnostics Function Yes
Diagnostics Indication Led
Run Led Yes
Error Led Yes
Maint Led Yes
Link Led Yes
Rx/Tx Led Yes
Potential Separation
Potential Separation Exists Yes
Isolation
Isolation Tested With 750 V Dc (Type Test) And According To En 50155 (Routine Test)
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 50.8 Kg
— Global Warming Potential, (During Production) [Co2
Eq]14.4 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]36.8 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.52 Kg
Railway Application
En 50121-3-2 Yes; Emc For Rail Vehicles
En 50121-4 Yes; Emc For Signal And Telecommunications Systems
En 50124-1 Yes; Railway Applications - Overvoltage Category Ov2; Pollution Degree Pd2;
Rated Surge Voltage Uni = 0.5 Kv; Unm = 24 V Dc
En 50125-1 Yes; Rail Vehicles - See Ambient Conditions
En 50125-2 Yes; Stationary Electrical Equipment - See Ambient Conditions
En 50125-3 Yes; Signal And Telecommunications Systems - See Ambient Conditions;
Vibrations And Shocks: Application Point Outside Of Tracks (1 M To 3 M Away
From Track)
En 50155 Yes; Rail Vehicles - Temperature Class Ot4, St1/St2, Horizontal Mounting
Position
En 61373 Yes; Rail Vehicles - Vibrations And Shocks: Category 1 Class A/B
Fire Protection Acc. To En 45545-2 Yes; For Proof Of Conformity, See Service & Support

Ambient Temperature During Operation

Horizontal Installation, Min. -40 °C; = Tmin (Incl. Condensation/Frost)
Horizontal Installation, Max. 70 °C; = Tmax; +85 °C For 10 Min (Ot4, St1/St2 Acc. To En 50155)
Vertical Installation, Min. -40 °C; = Tmin
Vertical Installation, Max. 55 °C; = Tmax
Ceiling Installation, Min. -40 °C; = Tmin
Ceiling Installation, Max. 45 °C; = Tmax
Floor Installation, Min. -40 °C; = Tmin
Floor Installation, Max. 45 °C; = Tmax
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 85 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Electronic Equipment On Rolling Stock Acc. To En 50155 Yes; Class Pc2 Protective Coating Acc. To En 50155:2017
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A

Dimensions

Width 70 Mm
Height 112 Mm
Depth 75 Mm
Weight S
Weight , Approx. 212 G
Other
Note: For Use In Railway Applications, Also Observe The Product Information "Siplus
Extreme Rail" A5E37661960A, Online Support Article 109736776

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us