This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AG2677-2DB40-2AA0

6AG2677-2DB40-2AA0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AG2677-2DB40-2AA0 Siemens

6AG2677-2DB40-2AA0 Siemens - SIPLUS ET 200SP CPU 1515SP PC2 rail spare based on 6ES7677-2DB40-0AA0 with conformal coating, -40…+60 °C, OT2 with ST1/2 (+70 °C für 10 minutes), spare part, 8 GB RAM, without CFast, interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet 2x USB 3.0; 2x USB 2.0, 1x display port

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AG2677-2DB40-2AA0
Product Description SIPLUS ET 200SP CPU 1515SP PC2 rail spare based on 6ES7677-2DB40-0AA0 with conformal coating, -40…+60 °C, OT2 with ST1/2 (+70 °C für 10 minutes), spare part, 8 GB RAM, without CFast, interfaces: 1x slot CFast, 1x slot SD/MMC, 1x connection for ET 200SP BusAdapter PROFINET, 1x 10/100/1000 Mbps Ethernet 2x USB 3.0; 2x USB 2.0, 1x display port
Product family SIPLUS ET 200SP CPU 1515SP PC2 RAIL
Product Lifecycle (PLM) PM300:Active Product
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations AL : N / ECCN : 5A991X
Estimated dispatch time (Working Days) 45 Day/Days
Net Weight (kg) 0,830 Kg
Packaging Dimension 14,20 x 18,90 x 9,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618101213
UPC Not available
Commodity Code 85371091
LKZ_FDB/ CatalogID A&DSE/SIP ADD
Product Group 4C03
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 18.09.2018
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Input Current
Current Consumption (Rated Value) 1.8 A; Full Processor Load, Incl. Et 200Sp Modules And Using Usb
Current Consumption (In No-Load Operation), Typ. 0.5 A
Current Consumption, Max. 2.9 A
I²T 0.426 A²·S; With Starting Current Inrush
Power
Active Power Input, Max. 43 W; Incl. Et 200Sp Modules And Using Usb
Infeed Power To The Backplane Bus 8.75 W
Power Loss
Power Loss , Typ. 16 W
Processor
Processor Type Intel Atom E3940, 1.6 Ghz, 4 Cores
Memory
Type Of Memory Ddr3L
Main Memory 8 Gb Ram
Cfast Memory Card No
Simatic Memory Card Required No
Hardware Configuration
Integrated Power Supply Yes
Number Of Dp Masters
Via Cm 1
Rack
Modules Per Rack, Max. 64; Cpu + 64 Modules + Server Module (Mounting Width Max. 1 M)
Time Of Day
Clock
Type Hardware Clock
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Interfaces
Number Of Industrial Ethernet Interfaces 2
Number Of Profinet Interfaces 1
Number Of Profibus Interfaces 1; Via Cm Dp Module
Number Of Rs 485 Interfaces 1; Via Cm Dp Module
Number Of Usb Interfaces 4; 2X Usb 2.0, 2X Usb 3.0 On Front Side
Number Of Sd Card Slots 1
Video Interfaces
Graphics Interface 1X Displayport
1. Interface
Interface Type Profinet
Interface Types
Rj 45 (Ethernet) Yes; Via Busadapter Ba 2X Rj45
— Transmission Rate, Max. 100 Mbit/S
— Industrial Ethernet Status Led Yes
Number Of Ports 2
Integrated Switch Yes
Busadapter (Profinet) Yes; Compatible Busadapter: Ba 2X Rj45, Ba 2X Fc, Ba 2X Scrj (From Fs03,
V2.2), Ba Scrj / Rj45 (From Fs03, V3.1), Ba Scrj / Fc (From Fs03, V3.1),
Ba 2X Lc (From Fs03, V3.3), Ba Lc / Rj45 (From Fs03, V3.3), Ba Lc / Fc
(From Fs03, V3.3)
2. Interface
Interface Type Integrated Ethernet Interface
Interface Types
Rj 45 (Ethernet) Yes; Integrated
— Transmission Rate, Max. 1 000 Mbit/S
— Industrial Ethernet Status Led No
Number Of Ports 1
Protocols
Open Ie Communication
Tcp/Ip
— Data Length, Max. 64 Kbyte
Isolation
Isolation Tested With 750 V Dc (Type Test) And According To En 50155 (Routine Test)
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 432 Kg
— Global Warming Potential, (During Production) [Co2
Eq]73.8 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]365 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-6.71 Kg
Railway Application
En 50121-3-2 Yes; Emc For Rail Vehicles
En 50121-4 Yes; Emc For Signal And Telecommunications Systems
En 50124-1 Yes; Railway Applications - Overvoltage Category Ov2; Pollution Degree Pd2;
Rated Surge Voltage Uni = 0.5 Kv; Unm = 24 V Dc
En 50125-1 Yes; Rail Vehicles - See Ambient Conditions
En 50125-2 Yes; Stationary Electrical Equipment - See Ambient Conditions
En 50125-3 Yes; Signal And Telecommunications Systems - See Ambient Conditions;
Vibrations And Shocks: Application Point Outside Of Tracks (1 M To 3 M Away
From Track)
En 50155 Yes; Rail Vehicles - Temperature Class Ot2, St1/St2, Horizontal Mounting
Position
En 61373 Yes; Rail Vehicles - Vibrations And Shocks: Category 1 Class A/B
Fire Protection Acc. To En 45545-2 Yes; For Proof Of Conformity, See Service & Support

Ambient Temperature During Operation

Min. -40 °C; = Tmin
Max. Up To 55 °C With Max. 64 Et 200Sp Modules, Max. 2X 900 Ma Usb Load And
Max. 2X 500 Ma Usb Load; Up To 60 °C With Max. 32 Et 200Sp Modules And
4X 500 Ma Usb Load; Fs06 Or Higher: Up To 70 °C With Max. 16 Et 200Sp
Modules, 4X 100 Ma Usb Load And No Visualization
Horizontal Installation, Min. -40 °C; = Tmin (Incl. Condensation/Frost)
Horizontal Installation, Max. 70 °C; = Tmax; +85 °C For 10 Min (Ot4, St1/St2 Acc. To En 50155)
Vertical Installation, Min. -40 °C; = Tmin
Vertical Installation, Max. 50 °C; = Tmax; With Max. 32 Et 200Sp Modules And Max. 4X 500 Ma Usb
Load
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Ambient Air Temperature-Barometric Pressure-Altitude Tmin ... Tmax At 1 140 Hpa ... 795 Hpa (-1 000 M ... +2 000 M)
Relative Humidity
With Condensation, Tested In Accordance With Iec 60068-
2-38, Max.100 %; Rh Incl. Condensation / Frost (No Commissioning In Bedewed State),
Horizontal Installation
Resistance
Coolants And Lubricants
— Resistant To Commercially Available Coolants And
Lubricantsyes; Incl. Diesel And Oil Droplets In The Air
Use In Stationary Industrial Systems
— To Biologically Active Substances According To En
60721-3-3Yes; Class 3B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 3B3 On Request
— To Chemically Active Substances According To En
60721-3-3Yes; Class 3C4 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-3Yes; Class 3S4 Incl. Sand, Dust, *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-3Yes; Class 3M8 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0//6Ag1193-6Ab00-0Aa0)
Use On Land Craft, Rail Vehicles And Special-Purpose Vehicles
— To Biologically Active Substances According To En
60721-3-5Yes; Class 5B2 Mold, Fungus And Dry Rot Spores (With The Exception Of Fauna);
Class 5B3 On Request
— To Chemically Active Substances According To En
60721-3-5Yes; Class 5C3 (Rh < 75 %) Incl. Salt Spray Acc. To En 60068-2-52 (Severity
Degree 3); *
— To Mechanically Active Substances According To En
60721-3-5Yes; Class 5S3 Incl. Sand, Dust; *
— Against Mechanical Environmental Conditions Acc.
To En 60721-3-5Yes; Class 5M2 Using The Siplus Mounting Kit Et 200Sp (6Ag1193-6Aa00-
0Aa0/6Ag1193-6Ab00-0Aa0)
— Against Mechanical Environmental Conditions In
Agriculture Acc. To Iso 15003Yes; Level 1 (Location Le) Using The Siplus Mounting Kit Et 200Sp
(6Ag1193-6Aa00-0Aa0/6Ag1193-6Ab00-0Aa0)
Usage In Industrial Process Technology
— Against Chemically Active Substances Acc. To En
60654-4Yes; Class 3 (Excluding Trichlorethylene)
— Environmental Conditions For Process, Measuring
And Control Systems Acc. To Ansi/Isa-71.04Yes; Level Gx Group A/B (Excluding Trichlorethylene; Harmful Gas
Concentrations Up To The Limits Of En 60721-3-3 Class 3C4 Permissible); Level
Lc3 (Salt Spray) And Level Lb3 (Oil)
Remark
— Note Regarding Classification Of Environmental
Conditions Acc. To En 60721, En 60654-4 And
Ansi/Isa-71.04* The Supplied Plug Covers Must Remain In Place Over The Unused Interfaces
During Operation!
Conformal Coating
Coatings For Printed Circuit Board Assemblies Acc. To En
61086Yes; Class 2 For High Reliability
Protection Against Fouling Acc. To En 60664-3 Yes; Type 1 Protection
Electronic Equipment On Rolling Stock Acc. To En 50155 Yes; Class Pc2 Protective Coating Acc. To En 50155:2017
Military Testing According To Mil-I-46058C, Amendment 7 Yes; Discoloration Of Coating Possible During Service Life
Qualification And Performance Of Electrical Insulating
Compound For Printed Board Assemblies According To Ipc-
Cc-830Ayes; Conformal Coating, Class A
Peripherals/Options
Sd Card Optionally For Additional Mass Storage

Dimensions

Width 160 Mm
Height 117 Mm
Depth 75 Mm
Weight S
Weight , Approx. 0.83 Kg
Other
Note: For Use In Railway Applications, Also Observe The Product Information "Siplus
Extreme Rail" A5E37661960A, Online Support Article 109736776

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible