This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6AV6645-0CB01-0AX0

6AV6645-0CB01-0AX0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6AV6645-0CB01-0AX0 Siemens

6AV6645-0CB01-0AX0 Siemens - *** spare part *** SIMATIC Mobile Panel 277 with integrated acknowledgment button and stop pushbutton, configurable with WinCC flexible Standard Version 2005 SP1 or higher or TIA Portal V11 to V14

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6AV6645-0CB01-0AX0
Product Description *** spare part *** SIMATIC Mobile Panel 277 with integrated acknowledgment button and stop pushbutton, configurable with WinCC flexible Standard Version 2005 SP1 or higher or TIA Portal V11 to V14
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2021
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : 5D992 / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 2,840 Kg
Packaging Dimension 38,80 x 39,40 x 20,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515089797
UPC 040892692389
Commodity Code 85371098
LKZ_FDB/ CatalogID ST80.1F
Product Group 4245
Group Code R141
Country of origin Austria
Compliance with the substance restrictions according to RoHS directive Since: 27.08.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Imidazolidine-2-thio... CAS-No. 96-45-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Imidazolidine-2-thione (2-imidazoline-2-thiol) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Design Of The Power Supply Via Connection Box
Type Of Supply Voltage Dc
Processor
Processor Type Arm, 520 Mhz
Memory
Type Of Memory Flash / Ram
Memory Available For User Data 6 Mbyte
Capacity Of Main Memory, Max. 128 Mbyte
Accumulator
Buffer Battery Yes; Maximum Buffer Time 10 Min
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive Yes
Synchronizable Yes
Interfaces
Interfaces/Bus Type 1X Rs 422, 1X Rs 485, 1X Ethernet (Rj45) (Max. 12 Mbit/S)
Number Of Industrial Ethernet Interfaces 1
Number Of Rs 485 Interfaces 1
Number Of Rs 422 Interfaces 1
Number Of Usb Interfaces 1
Number Of Wireless Interfaces 0
Multimedia Card/Sd Card Slot 1 Mmc/Sd Card Slot
Protocols
Supports Protocol For Profinet Io Yes
Profisafe No
Profibus Yes
Ethernet /Ip Yes
As-Interface No
Protocols (Ethernet)
Tcp/Ip Yes
Further Protocols
Modbus Yes
Other Bus Systems Yes
Communication Functions / Header
Wireless Communication
Supported Standards
— Radio Standard Wlan 802.11 No
Standards, Approvals, Certificates
Certificate Of Suitability Ce, Culus, C-Tick, Sibe
Ce Mark Yes
Culus Yes
Rcm (Formerly C-Tick) Yes
Suitable For Safety Functions Yes
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 D

Ambient Conditions

Free Fall
Fall Height, Max. 1.2 M

Ambient Temperature During Operation

Min. 0 °C
Max. 40 °C
Ambient Temperature During Storage/Transportation
Min. -20 °C
Max. 60 °C
Relative Humidity
Operation, Max. 80 %

Operating Systems

Pre-Installed Operating System Windows Ce
Configuration / Header
Message Indicator Yes
Alarm System (Incl. Buffer And Acknowledgment) Yes
Process Value Display (Output) Yes
Process Value Default (Input) Possible Yes
Recipe Management Yes
Configuration Software
Configuration Tool Wincc Flexible Standard Version 2005 Sp1 Or Higher (To Be Ordered Separately)
Wincc Flexible Compact No
Wincc Flexible Standard Yes
Wincc Flexible Advanced Yes
Wincc Basic (Tia Portal) No
Wincc Comfort (Tia Portal) Yes
Wincc Advanced (Tia Portal) Yes
Wincc Professional (Tia Portal) Yes
Languages
Online Languages
Number Of Online/Runtime Languages 16
Project Languages
Languages Per Project 32
Functionality Under Wincc (Tia Portal)
Libraries Yes
Applications/Options Internet Explorer, Sm@Rtservice, Sm@Rtaccess
Web Browser Yes
Simatic Wincc Sm@Rtserver Yes
Connection Point Identification Yes
Number Of Visual Basic Scripts Yes
Task Planner Yes
Help System Yes
Number Of Characters Per Info Text 70
Message System
Number Of Alarm Classes 32
Bit Messages Yes
— Number Of Bit Messages 4 000
Analog Messages Yes
— Number Of Analog Messages 4 000
System Messages Hmi Yes
System Messages Plc Yes
System Event, More (Simatic S7, Sinumerik,
Simotion, ... )Yes
Lines 1
Number Of Characters Per Message 80
Number Of Process Values Per Message 8
Acknowledgment Groups
— Number Of Acknowledgement Groups 99
Message Indicator Yes
First/Last Value Yes
Recipe Management
Number Of Recipes 300
Data Records Per Recipe 500
Entries Per Data Record 1 000
Recipe Memory 64 Kb Integrated Flash, Expandable
Variables
Number Of Variables Per Device 2 048
Number Of Variables Per Screen 200
Number Of Variables 1 000
Initial Values 2 048
Type Date & Time 2 048
Limit Values Yes
Multiplexing Yes
Structures Yes
Images
Number Of Configurable Images 500
Permanent Window/Default Yes
Start Screen Configurable Yes
Image Selection By Plc Yes
Image Number In The Plc Yes
Image Objects
Text Objects 10 000 Text Elements
Number Of I/O Fields Per Image 200
Number Of Date/Time Fields 200
Return Yes
Graphics Object Bit Maps, Icons, Vector Graphics
— Icons 1 000
Complex Image Objects
Status/Control Yes; With Simatic S7
Dynamic Objects Diagrams, Bar Graphs, Sliders, Analog Display, Invisible Buttons
— Number Of Objects Per Project 1 000
— Number Of Curve Diagrams Per Image 10
Methods Trend / Profile
Bar Graphs
— Number Of Bars Per Chart 10
Sliders
— Number Of Slides Per Image 10
Pointer Instruments
— Number Of Analog Indicators Per Image 10
Limit Value Lines Yes
Number Of Alphanumerical Fields 300
— Alphanumeric Fields Per Image 200
Number Of Numerical Fields 2 048
— Numerical Fields Per Image 200
Number Of Password Fields 2 048
Number Of Visible Switches Per Project 200
— Visible Switches Per Image 200
— Hidden Switches Per Image 200
Number Of Status Switches Per Project 200
— Number Of Status Switches Per Image 200
Number Of Selector Switches Per Project 200
— Selector Switches Per Image 200
Number Of Decade Switches Per Project 200
— Decade Switches Per Image 200
Number Of Signal Lamps Per Project 200
— Signal Lamps Per Image 200
Attributes For Dynamic Objects
Color Change Yes
X/Y Movement Yes
Hide Yes
Lists
Number Of Text Lists Per Project 500
Number Of Text Lists Per Image 200
Number Of Entries Per Text List 256
Number Of Graphics Lists Per Project 400
Number Of Graphic Lists Per Image 200
Number Of Entries Per Graphics List 256
Archiving
Number Of Archives Per Device 20
Number Of Measuring Points Per Project 20
Number Of Entries Per Archive 10 000
Message Archive Yes
Process Value Archive Yes
Archiving Methods
— Sequential Archive Yes
— Short-Term Archive Yes
Memory Location Multimediacard
Data Storage Format
— Csv Yes
Online Evaluation
— Using Trend Curves Yes
Filters
Cyclic Yes
Tolerance Yes
Change Yes
Security
Number Of User Groups 50
Number Of User Rights 32
Password Export/Import Yes
Logging Through Printer
Recording/Printing Alarms, Report (Shift Report), Color Print, Hardcopy
Transfer (Upload/Download)
Transfer Of Configuration Mpi/Profibus Dp, Usb, Ethernet, Automatic Transfer Recognition
Process Coupling
Connection To Controller S5, S7-200, S7-300/400, Ti 505, Sinumerik, Simotion, Allen Bradley
(Df1), Allen Bradley (Df485), Mitsubishi (Fx), Omron (Link/Multilink),
Modicon (Modbus), Further Non-Siemens Drivers, See Chapter "System
Interfaces"
S7-1200 Yes
S7-1500 Yes
S7-200 Yes
— Ppi (Point-To-Point) Yes
— Ppi Network Yes
— Product Function / For Process Coupling / With S7-200
/ For Wincc In The Tia Portal / Mpiyes
— Product Function / For Process Coupling / With S7-200
/ For Wincc In The Tia Portal / Profibus Dpyes
— Ethernet Yes
S7-300/400 Yes
— Mpi Yes
— Profibus Dp Yes
— Profinet Yes
Sinumerik Yes
Simotion Yes
S5 Yes
— Serial Yes
— Profibus Dp Yes
Ti 505 Yes
Allen Bradley (Df1) Yes
Allen Bradley (Df485) Yes
Mitsubishi (Fx) Yes
Mitsubishi (Mp4) Yes
Omron (Link/Multilink) Yes
Modicon (Modbus) Yes
Ge-Fanuc (Snp) Yes
Functions
Tab Sequence Yes
Calculating Functions Yes
Animate Yes
Service Tools/Configuration Aids
Clean Screen Yes
Touch Calibration Yes
Backup/Restore Manually Yes
Simulation Yes
Device Switchover Yes
Delta Transfer Yes
Peripherals/Options
Peripherals Printer, Barcode Reader
Printer Yes
Simatic Hmi Mm Memory Card: Multi Media Card Yes
Simatic Hmi Sd Memory Card: Secure Digital Memory Card Yes
Usb Memory Yes
Additional Software Components Loadable Yes
Mechanics/Material
Enclosure Material (Front) Plastic

Dimensions

Enclosure Diameter 290 Mm
Depth Of Housing 103 Mm
Weight S
Weight (Without Packaging) 1.7 Kg

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible