6BK1700-2BA30-0AA0 Siemens - ***spare part*** SIPLUS HCS724I Central connection ZA724I Connection to PROFIBUS DP 12 Mbaud

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6BK1700-2BA30-0AA0
Product Description ***spare part*** SIPLUS HCS724I Central connection ZA724I Connection to PROFIBUS DP 12 Mbaud
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.07.2017
Notes Sucessor:Successor system HCS4200 (6BK1942-X) is not fully compatible This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 30 Day/Days
Net Weight (kg) 5,220 Kg
Packaging Dimension 50,00 x 210,00 x 480,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN Not available
UPC 662643034523
Commodity Code 85389091
LKZ_FDB/ CatalogID ES-NB1
Product Group 4359
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Product is not RoHS-compliant
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation No
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Type Of Supply Voltage Ac
Rated Value (Ac) 230 V
Line Frequency
Rated Value 50 Hz Yes
Rated Value 60 Hz Yes
Relative Symmetrical Tolerance 5 %
Mains Buffering
Mains/Voltage Failure Stored Energy Time 20 Ms
Recovery Time After Power Failure, Typ. 1 S
Connection Method
Design Of Electrical Connection For Supply Voltage Terminal, 2-Pole
— Connectable Conductor Cross-Sections, Solid 1X (0.5 ... 2.5 Mm²)
— Connectable Conductor Cross-Sections, Finely
Stranded With Wire End Processing1X (0.5 ... 2.5 Mm²)
— Connectable Conductor Cross-Sections For Awg
Cables26 ... 14
Power
Active Power Input 35 W
Hardware Configuration
Type Of Power Output Connectable La724I / La724I Hp / La724I Ssr
Interfaces
Interfaces/Bus Type Profibus Dp
Profibus Dp
Transmission Rate, Max. 12 Mbit/S
Design Of Electrical Connection 9-Pin Sub D Socket
Protocols
Profibus Dp Yes
Interrupts/Diagnostics/Status Information
Number Of Status Displays 2
Led Status Display Led Green = Status Indicator, Led Red = Fault Indicator
Isolation
Overvoltage Category Iii
Degree Of Pollution 2
Emc
Emc Interference Emission Limit Value Class A To En 55011 Group 1
Electrostatic Discharge Acc. To Iec 61000-4-2 4 Kv Contact Discharge / 8 Kv Air Discharge
Field-Related Interference Acc. To Iec 61000-4-3 10 V/M (80 ... 1 000 Mhz), 3 V/M (1.4 ... 2.0 Ghz), 1 V/M (2.0 ... 2.7 Ghz)
Conducted Interference Due To Burst Acc. To Iec 61000-4-4 2 Kv Voltage Supply Cables / 2 Kv Signal Cables
Conducted Interference Due To Surge Acc. To Iec 61000-4-5 On Supply Lines: 1 Kv Symmetrical, 2 Kv Asymmetrical, Profibus Cable
Asymmetrical 1 Kv
Conducted Interference Due To High-Frequency Radiation Acc. To
Iec 61000-4-610 V (0.15 ... 80 Mhz)
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Certificate Of Suitability Ce, Kcc
Ce Mark Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
China Rohs Compliance Yes
Reference Designation According To Iec 81346-2 (2009) K

Ambient Temperature During Operation

Min. 0 °C
Max. 55 °C
Ambient Temperature During Storage/Transportation
Storage, Min. -40 °C
Storage, Max. 70 °C
Transportation, Min. -40 °C
Transportation, Max. 70 °C
Air Pressure Acc. To Iec 60068-2-13
Operation, Min. 860 Hpa
Operation, Max. 1 080 Hpa
Storage, Min. 660 Hpa
Storage, Max. 1 080 Hpa
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Relative Humidity
Operation At 25 ℃, Max. 95 %
Vibrations
Vibration Resistance During Operation Acc. To Iec 60068-
2-610 ... 58 Hz / 0.15 Mm, 58 ... 150 Hz / 1 G
Vibration Resistance During Storage Acc. To Iec 60068-2-6 5 ... 9 Hz / 3.5 Mm, 9 ... 500 Hz / 1 G
Shock Testing
Shock Resistance During Operation Acc. To Iec 60068-2-
2715 G / 11 Ms / 3 Shocks/Axis
Shock Resistance During Storage Acc. To Iec 60068-2-29 25 G / 6 Ms / 1 000 Shocks/Axis

Dimensions

Width 50 Mm
Height 480 Mm
Depth 210 Mm