Description for 6BK1942-2CA00-0AA1 Siemens

6BK1942-2CA00-0AA1 Siemens - SIPLUS HCS4200 POM4220 Midrange phase angle with 12 outputs each max. 3680 W (at 230 V AC)

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6BK1942-2CA00-0AA1
Product Description ***spare part*** SIPLUS HCS4200 POM4220 Midrange phase angle with 12 outputs each max. 3680 W (at 230 V AC)
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2024
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : 3A991X / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 1,500 Kg
Packaging Dimension 312,00 x 374,00 x 107,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047618077204
UPC 804766555251
Commodity Code 85389091
LKZ_FDB/ CatalogID ES-NB1
Product Group 4359
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 11.10.2016
Product class B: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Type Of Supply Voltage Ac
Rated Value (Ac) 230 V; Phase - Neutral Conductor
Relative Negative Tolerance 10 %
Relative Positive Tolerance 30 %
2Nd Rated Value (Ac) 277 V; Phase - Neutral Conductor
Relative Negative Tolerance 25 %
Relative Positive Tolerance 8 %
Line Frequency
Rated Value 50 Hz Yes
Rated Value 60 Hz Yes
Relative Symmetrical Tolerance 5 %
Mains Buffering
Recovery Time After Power Failure, Typ. 1 S
Connection Method
Design Of Electrical Connection For Supply Voltage Plug, 3-Pole With Spring-Type Terminal, Push-In
— Connectable Conductor Cross-Sections, Solid 1X (0.75 ... 16 Mm²)
— Connectable Conductor Cross-Sections, Finely
Stranded With Wire End Processing1X (0.75 ... 16 Mm²)
— Connectable Conductor Cross-Sections For Awg
Cables1X (18 ... 4)
Input Voltage
Device Version Of The Power Supply For Electronics Power Supply Via Rack
Power
Active Power Input, Max. 1 W
Power Electronics
Type Of Load Ohmic Load
Power Capacity, Max. 29.4 Kw; At 230 V Ac
For Phase Against Neutral With Fan At 40 °C, Max. 29.4 Kw; At 230 V Ac
For Phase Against Neutral Without Fan At 40 °C, Max. 7.3 Kw; At 230 V Ac
Switching Capacity Current Per Phase, Max. 64 A
Short-Time Withstand Current (Sccr) Acc. To Ul 508A 100 Ka
Control Of Heating Elements
Half-Wave Control Yes
Soft Start Yes
Phase Control Yes
Load Connection Type
Star Connection With Neutral Conductor (Single-Phase) Yes
Open Delta Connection (Single-Phase) No
Closed Delta Connection (2-Phase) No
Closed Delta Connection (3-Phase) No
Star Connection With Neutral Conductor (2-Phase) No
Star Connection Without Neutral Conductor (3-Phase) No
2-Pole Switching No
Setpoint Input
Percent Yes
Watts No
Heating Power
Number Of Digital Outputs 12
Number Of Heating Elements Per Output, Max. 1
Output Voltage For Heating Power 230 V
2Nd Output Voltage For Heating Power 277 V
Power Carrying Capacity Per Output, Min. 60 W; At 230 V Ac
Power Carrying Capacity Per Output, Max. 3 680 W; At 230 V Ac
— For Heating Elements With High Inrush Current, Max. 1 600 W; At 230 V Ac
Output Current For Heating Power 16 A; Max.
Melting I2T Value 20 A²·S
Design Of Short-Circuit Protection Per Output Fuse 16 A
Design Of Overvoltage Protection Transil Diode
Connection Method
Design Of Electrical Connection At Output For Heating And
Fanplug, 6-Pole With Spring-Type Terminal, Push-In
— Connectable Conductor Cross-Sections, Solid 1X (0.2 ... 10 Mm²)
— Connectable Conductor Cross-Sections, Finely
Stranded With Wire End Processing1X (0.25 ... 6 Mm²)
— Connectable Conductor Cross-Sections For Awg
Cables, Stranded1X (24 ... 8)
Interfaces
Interfaces/Bus Type System Interface
Interrupts/Diagnostics/Status Information
Number Of Status Displays 15
Led Status Display Led Green = Ready, Led Yellow = Heating On/Off, Led Red = Error Display, Led
Red = Error For Each Channel
Diagnostics Function Voltage Diagnostics
Diagnoses
Fuse Blown Yes
Load Failure Yes
Triac Error Yes
Switch-Off Threshold For Internal Device Temperature Yes
Parallel-Connected Heating Elements No
Rotating Field Fault No
Communication Error Yes
Supply Voltage Not Connected Yes
Line Voltage Outside The Permissible Range No
Frequency Outside The Permissible Range Yes
Fault Current Too High No
Integrated Functions
Monitoring Functions
Temperature Monitoring Yes
Type Of Temperature Monitoring Ntc Thermistor

Measuring Functions

Voltage Measurement No
Current Measurement No
Fault Current Detection No
Potential Separation
Design Of Electrical Isolation Optocoupler And/Or Protective Impedance Between Main Circuit And Pelv
Between The Outputs No
Isolation
Overvoltage Category Iii
Degree Of Pollution 2
Emc
Emc Interference Emission Limit Value In Accordance With Iec 61000-6-4:2007 + A1:2011
Electrostatic Discharge Acc. To Iec 61000-4-2 4 Kv Contact Discharge / 8 Kv Air Discharge
Field-Related Interference Acc. To Iec 61000-4-3 10 V/M (80 ... 1 000 Mhz), 3 V/M (1.4 ... 2.0 Ghz), 1 V/M (2.0 ... 2.7 Ghz)
Conducted Interference Due To Burst Acc. To Iec 61000-4-4 2 Kv Power Supply Lines, 2 Kv Load Lines
Conducted Interference Due To Surge Acc. To Iec 61000-4-5 Supply And Load Lines: 1 Kv Symmetrical, 2 Kv Asymmetrical
Conducted Interference Due To High-Frequency Radiation Acc. To
Iec 61000-4-610 V (0.15 ... 80 Mhz)
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
China Rohs Compliance Yes
Reference Designation According To Iec 81346-2 (2009) Q

Ambient Temperature During Operation

Min. 0 °C
Max. 55 °C
Ambient Temperature During Storage/Transportation
Storage, Min. -25 °C
Storage, Max. 70 °C
Transportation, Min. -25 °C
Transportation, Max. 70 °C
Air Pressure Acc. To Iec 60068-2-13
Operation, Min. 860 Hpa
Operation, Max. 1 080 Hpa
Storage, Min. 660 Hpa
Storage, Max. 1 080 Hpa
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 2 000 M
Relative Humidity
Operation At 25 ℃, Max. 95 %
Operation At 50 ℃, Max. 50 %; 95 % At 25 °C, Decreasing Linearly To 50 % At 50 °C
Vibrations
Vibration Resistance During Operation Acc. To Iec 60068-
2-610 ... 58 Hz / 0.075 Mm, 58 ... 150 Hz / 1 G
Vibration Resistance During Storage Acc. To Iec 60068-2-6 5 ... 8.5 Hz / 3.5 Mm, 8.5 ... 500 Hz / 1 G
Shock Testing
Shock Resistance During Operation Acc. To Iec 60068-2-
2715 G / 11 Ms / 3 Shocks/Axis
Shock Resistance During Storage Acc. To Iec 60068-2-29 25 G / 6 Ms / 1 000 Shocks/Axis

Dimensions

Width 36 Mm
Height 285 Mm
Depth 281 Mm