Description for 6EP4134-0JA00-0AY0 Siemens

6EP4134-0JA00-0AY0 Siemens - SITOP BAT1600/BATT.MODUL/24V/7.5AH

Extended Description for 6EP4134-0JA00-0AY0 Siemens

6EP4134-0JA00-0AY0 Siemens - SITOP BAT1600 24 V DC 7.5 Ah LiFePO4 lithium battery for SITOP UPS1600 *** not for air freight ***

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6EP4134-0JA00-0AY0
Product Description SITOP BAT1600 24 V DC 7.5 Ah LiFePO4 lithium battery for SITOP UPS1600 - - not for air freight - -
Product family SITOP BAT1600 battery modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 4,000 Kg
Packaging Dimension 34,00 x 24,00 x 15,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515155850
UPC Not available
Commodity Code 85076000
LKZ_FDB/ CatalogID KT10-PD
Product Group 4215
Group Code R315
Country of origin Austria
Compliance with the substance restrictions according to RoHS directive Given
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Electrical Data

End-Of-Charge Voltage At Dc
At -10 °C Recommended 28.8 V
At 0 °C Recommended 28.8 V
At 10 °C Recommended 28.8 V
At 20 °C Recommended 28.8 V
At 30 °C Recommended 28.8 V
At 40 °C Recommended 28.8 V
At 50 °C Recommended 28.8 V
Output
Battery Capacity 7.5 A·H
Output Current Rated Value 40 A
Output Current In Buffering Mode Maximum 40 A
Peak Current 120 A; For 30 Ms
Charging Current Maximum 3 A
Output Voltage At Dc Rated Value 24 V
Interfaces
Communication Function Yes
Protection And Monitoring
Design Of Short-Circuit Protection 50A / 32V Maxi Flat Fuse
Display Version For Normal Operation Three-Color: Green = Buffer Ready; Yellow = Buffer Endangered; Red = Buffer Not
Possible
Safety
Operating Resource Protection Class Class Iii
Protection Class Ip Ip20

Standards, Specifications, Approvals

Certificate Of Suitability
Ce Marking Yes
Ul Approval Yes; Culus-Listed (Ul 61010-1, Ul61010-2-201 , Csa C22.2 No. 61010-1,
Csa C22.2 No 61010-2-201), File E143289
Csa Approval Yes; Ccsaus (Csa C22.2 No. 62368-1, Ul 62368-1)
Ukca Marking Yes
Type Of Certification Cb-Certificate Yes
Standards, Specifications, Approvals Hazardous Environments
Certificate Of Suitability
Atex No
Ccsaus, Class 1, Division 2 No
Standards, Specifications, Approvals Marine Classification
Shipbuilding Approval Yes
Marine Classification Association
American Bureau Of Shipping Europe Ltd. (Abs) Yes
Det Norske Veritas (Dnv) In Preparation

Ambient Conditions

Ambient Condition For Storage, Mounting And Operation Of Batteries, The Relevant Din/Vde
Regulations Or Country-Specific Regulations (E.G. Vde 0510 Part 2/En 50272-2)
Must Be Observed.
Ambient Temperature
During Operation -10 ... +50
During Transport -30 ... +70
During Storage -20 ... +35
Relative Temporary Capacity Loss At 20 °C In A Month Typical 1 %
Service Life Of Energy Storage
Typical Capacity Falls To 80 % Of Original Capacity (According To Eurobat)
At 20 °C Typical 11 A
At 30 °C Typical 11 A
At 40 °C Typical 8 A
At 50 °C Typical 6 A
At 60 °C Typical 2 A
Note Along With The Storage And Operating Temperature, Other Factors Such As The
Duration Of The Storage Period And The Charge Status During Storage Have A
Decisive Influence On The Possible Useful Life. Batteries Should Therefore Be
Stored As Briefly As Possible, Always Fully Charged, And Within The Temperature
Range 0 To +20 °C.
Connection Method
Type Of Electrical Connection Screw Terminal
For Ups Module 1 Screw Terminal Each For 0.5 ... 16 Mm² For + Bat And - Bat
For Control Circuit And Status Message 1 Screw Terminal Each For 0.2 ... 2.5 Mm²

Mechanical Data

Width × Height × Depth Of The Enclosure 238 × 156 × 129 Mm
Installation Width × Mounting Height 238 Mm × 256 Mm
Required Spacing
Top 50 Mm
Bottom 50 Mm
Left 0 Mm
Right 0 Mm
Fastening Method Snaps Onto Din Rail En 60715 35X15 Or Wall Mounting With Accessories Wall
Mounting Set 6Ep4990-0Mk00-0Xu0
Standard Rail Mounting Yes
S7 Rail Mounting Yes
Wall Mounting Yes
Net Weight 4 Kg
Number Of Cells 3
Accessories
Product Component Included 2X Maxi Fuse 50 A/32 V
Mechanical Accessories Bat1600 Wall Mounting Kit 6Ep4990-0Mk00-0Xu0
Further Information Internet Links
Internet Link
To Website: Industry Mall Https://Mall.Industry.Siemens.Com
To Web Page: Selection Aid Tia Selection Tool Https://Www.Siemens.Com/Tstcloud
To Website: Cax-Download-Manager Https://Www.Siemens.Com/Cax
To Website: Industry Online Support Https://Support.Industry.Siemens.Com
Additional Information
Other Information Specifications At Rated Input Voltage And Ambient Temperature +25 °C (Unless
Otherwise Specified)
Security Information
Siemens Provides Products And Solutions With Industrial Cybersecurity Functions
That Support The Secure Operation Of Plants, Systems, Machines And Networks.
In Order To Protect Plants, Systems, Machines And Networks Against Cyber
Threats, It Is Necessary To Implement – And Continuously Maintain – A Holistic,
State-Of-The-Art Industrial Cybersecurity Concept. Siemens’ Products And
Solutions Constitute One Element Of Such A Concept. Customers Are Responsible
For Preventing Unauthorized Access To Their Plants, Systems, Machines And
Networks. Such Systems, Machines And Components Should Only Be Connected
To An Enterprise Network Or The Internet If And To The Extent Such A Connection Is
Necessary And Only When Appropriate Security Measures (E.G. Firewalls And/Or
Network Segmentation) Are In Place. For Additional Information On Industrial Security Information
Cybersecurity Measures That May Be Implemented, Please Visit
Www.Siemens.Com/Cybersecurity-Industry. Siemens’ Products And Solutions
Undergo Continuous Development To Make Them More Secure. Siemens Strongly
Recommends That Product Updates Are Applied As Soon As They Are Available
And That The Latest Product Versions Are Used. Use Of Product Versions That Are
No Longer Supported, And Failure To Apply The Latest Updates May Increase
Customer’S Exposure To Cyber Threats. To Stay Informed About Product Updates,
Subscribe To The Siemens Industrial Cybersecurity Rss Feed Under
Https://Www.Siemens.Com/Cert. (V4.7)
Classifications
Version Classification
Eclass 14 27-05-04-03
Eclass 12 27-05-04-03
Eclass 9.1 27-05-04-03
Eclass 9 27-05-04-03
Eclass 8 27-05-04-03
Eclass 7.1 27-05-04-03
Eclass 6 27-05-04-90
Etim 9 Ec000357
Etim 8 Ec000357
Etim 7 Ec000357

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible