Siemens

6ES7134-6PA21-0CU0

6ES7134-6PA21-0CU0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7134-6PA21-0CU0 Siemens

6ES7134-6PA21-0CU0 Siemens - SIMATIC ET 200SP, analog input module, AI Energy Meter RC HF, for Rogowski coils or current/voltage transformer 333 mV, with network analysis functions, suitable for BU type U0, channel diagnostics

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£274.47 Exc. VAT
£329.36 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7134-6PA21-0CU0
Product Description SIMATIC ET 200SP, analog input module, AI Energy Meter RC HF, for Rogowski coils or current/voltage transformer 333 mV, with network analysis functions, suitable for BU type U0, channel diagnostics
Product family Analog input modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,043 Kg
Packaging Dimension 6,50 x 7,70 x 2,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623411741
UPC 195125281585
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group 4520
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.07.2021
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Voltage Measurement Yes
— Without Voltage Transformer Yes
— With Voltage Transformer Yes
Current Measurement Yes; Max. 4
— Without Current Transformer No
— With Current Transformer No
— With Rogowski Coil Yes
— With Current-Voltage-Converter Yes; 333 Mv Interface
Energy Measurement Yes
Frequency Measurement Yes
Power Measurement Yes
Active Power Measurement Yes
Reactive Power Measurement Yes
Power Factor Measurement Yes
Active Factor Measurement Yes
Reactive Power Compensation Yes
Line Analysis Yes
— Monitoring Of Instantaneous And Half-Wave Values Yes
— Thd Measurement For Current And Voltage Yes
— Harmonics For Current And Voltage Yes
— Voltage Dip (Dip) Yes
— Voltage Swell Yes
I&M Data Yes; I&M0 To I&M3
Isochronous Mode No
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version Step 7 V16 Or Higher With Hsp
Step 7 Configurable/Integrated From Version V5.5 Sp3 Or Higher
Profibus From Gsd Version/Gsd Revision One Gsd File Each, Revision 3 And 5 And Higher
Profinet From Gsd Version/Gsd Revision V2.3
Operating Mode
Switching Between Operating Modes In Run Yes; For Module Version 32 I/20 Q, It Is Possible To Dynamically Switch Between
25 User Data Variants, 23 Of Which Are Pre-Defined And 2 Of Which Can Be
Defined By The Specific User
Cyclic Measured Value Access Yes
Acyclic Measured Value Access Yes
Fixed Measured Value Sets Yes
Freely Definable Measured Value Sets Yes; For Cyclic And Acyclic Measured Value Access
Cir - Configuration In Run
Reparameterization Possible In Run Yes
Calibration Possible In Run Yes
Installation Type/Mounting
Mounting Position Any

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
Current Consumption (Rated Value) 12.5 Ma
Current Consumption, Max. 17 Ma
Power Loss
Power Loss , Typ. 400 Mw; 3X 230 V Ac
Address Area
Address Space Per Module
Inputs 256 Byte
Outputs 20 Byte
Hardware Configuration
Automatic Encoding Yes
Mechanical Coding Element Yes
Type Of Mechanical Coding Element Type C
Selection Of Baseunit For Connection Variants
2-Wire Connection Bu Type U0
Time Of Day
Operating Hours Counter
Present Yes

Analog Inputs

Cycle Time (All Channels), Typ. 50 Ms; Time For Consistent Update Of All Measured And Calculated Values (Cyclic
Und Acyclic Data)
Cable Length
Shielded, Max. 200 M
Unshielded, Max. 200 M
Analog Value Generation For The Inputs
Sampling Frequency, Max. 2 048 Khz
Interrupts/Diagnostics/Status Information
Alarms
Diagnostic Alarm Yes
Limit Value Alarm Yes
Hardware Interrupt Yes; Monitoring Of Up To 16 Freely Selectable Process Values (Exceeding Or
Undershooting Of Value)
Diagnoses
Line Quality Yes
Supply Voltage Yes
Hardware Interrupt Lost Yes
Parameter Assignment Error Yes
Module Fault Yes
Channel Not Available Yes
Overflow/Underflow Yes
Overload Current Yes
Diagnostics Indication Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Fn Led
For Module Diagnostics Yes; Green/Red Diag Led
Integrated Functions

Measuring Functions

Measuring Procedure For Voltage Measurement Trms
Measuring Procedure For Current Measurement Trms
Type Of Measured Value Acquisition Seamless
Curve Shape Of Voltage Sinusoidal Or Distorted
Buffering Of Measured Variables Yes
Parameter Length 128 Byte
Bandwidth Of Measured Value Acquisition 3.2 Khz; Harmonics: 63 / 50 Hz, 52 / 60 Hz
Measuring Range
— Frequency Measurement, Min. 40 Hz
— Frequency Measurement, Max. 70 Hz
Measuring Inputs For Voltage
— Measurable Line Voltage Between Phase And Neutral
Conductor277 V
— Measurable Line Voltage Between The Line
Conductors480 V
— Measurable Line Voltage Between Phase And Neutral
Conductor, Min.3 V
— Measurable Line Voltage Between Phase And Neutral
Conductor, Max.300 V
— Measurable Line Voltage Between The Line
Conductors, Min.6 V
— Measurable Line Voltage Between The Line
Conductors, Max.519 V
— Internal Resistance Line Conductor And Neutral
Conductor1.5 M Ω
— Power Consumption Per Phase 60 Mw; 300 V Ac
— Impulse Voltage Resistance 1,2/50Μs 2.5 Kv
— Overvoltage Category Cat Ii According To Iec 61010 Part 1
Measuring Inputs For Current (Rog. Or I/U Converter)
— Measurable Current At Ac, Max. 424 Mv
— Continuous Voltage, Maximum Permissible 2 V
— Rated Value, Short-Time Withstand Voltage Restricted
To 1 S30 V
— Input Resistance 120 K Ω
— Zero Point Suppression Yes; 0 ... 20%, Referred To The Nominal Current
Accuracy Class According To Iec 61557-12
— Measured Variable Voltage 0,2
— Measured Variable Current 0,2
— Measured Variable Apparent Power 0.5
— Measured Variable Active Power 0.5
— Measured Variable Reactive Power 1
— Measured Variable Power Factor 0.5
— Measured Variable Active Energy 0.5
— Measured Variable Reactive Energy 1
— Measured Variable Neutral Current 0,2
— Measured Variable Phase Angle ±0.5 °; Not Covered By Iec 61557-12
— Measured Variable Frequency 0.05; Only Valid For The Permissible Voltage Measuring Range
— Measured Variable Harmonic 1
— Measured Variable Thdu 1
— Measured Variable Thdi 1
Accuracy Class Line Analysis Acc. To Iec 61000-4-30
— Measured Variable Voltage Class S
— Measured Variable Current Class S
— Measured Variable Frequency Class S
— Measured Variable Voltage Interruption Class S
— Measured Variable Voltage Dip And Swell Class S
— Measured Variable Harmonic Voltage Class S
— Measured Variable Harmonic Current Class S
Potential Separation
Potential Separation Channels
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ Yes; Including Fe
Isolation
Isolation Tested With Between Channels And Backplane Bus, 24 V Supply: Routine Test, 1 920 V Ac,
2 S; Between Backplane Bus And 24 V Supply: Type Test, 707 V Dc

Ambient Temperature During Operation

Horizontal Installation, Min. -30 °C
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. -30 °C
Vertical Installation, Max. 50 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 3 000 M; Restrictions For Installation Altitudes > 2 000 M, See Manual

Dimensions

Width 20 Mm
Height 73 Mm
Depth 58 Mm
Weight S
Weight , Approx. 45 G
Other
Data For Selecting A Voltage Transformer
Secondary Side, Max. 300 V

Documentation