Description for 6ES7136-6CB00-0CA0 Siemens

6ES7136-6CB00-0CA0 Siemens - SIMATIC ET 200SP, F-TM Count 1x1Vpp sin/cos HF, PROFIsafe, 1 channel, for incremental rotary encoders, sin/cos 1 Vpp, suitable for BU type A0, pack quantity: 1 unit

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£451.64 Exc. VAT
£541.97 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7136-6CB00-0CA0
Product Description SIMATIC ET 200SP, F-TM Count 1x1Vpp sin/cos HF, PROFIsafe, 1 channel, for incremental rotary encoders, sin/cos 1 Vpp, suitable for BU type A0, pack quantity: 1 unit
Product family Fail-safe technology modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,054 Kg
Packaging Dimension 6,80 x 7,70 x 2,70
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623411413
UPC 195125336025
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 4527
Group Code R152
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 12.10.2020
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version Step 7 V17 Or Higher: Use Gsdml For Prior Versions

Supply Voltage

Rated Value (Dc) 24 V
Power Supply According To Nec Class 2 Required No
Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Input Current
Current Consumption, Max. 50 Ma; Without Load, 150 Ma With 300 Ma Encoder Load
Encoder Supply
5 V Encoder Supply
5 V Yes; 5.1 V ±3.5 %
Short-Circuit Protection Yes; Electronic Overload Protection; No Protection On Applying A Normal Or
Counter Voltage.
Output Current, Max. 300 Ma
Power Loss
Power Loss , Typ. 1.25 W
Address Area
Address Space Per Module
Inputs 14 Byte; S7-300/400F Cpu, 13 Byte
Outputs 5 Byte; S7-300/400F Cpu, 4 Byte
Hardware Configuration
Automatic Encoding Yes
Electronic Coding Element Type H Yes
Digital Inputs
Number Of Digital Inputs 1; (Counter Input)
Digital Inputs, Parameterizable Yes
Digital Input Functions, Parameterizable
Gate Start/Stop Yes
Counter For Incremental Encoder Yes
— Number, Max. 1
Input Voltage
Type Of Input Voltage Sin/Cos 1 Vpp
Input Delay (For Rated Value Of Input Voltage)
Minimum Pulse Width For Program Reactions 2.5 Μs For Parameterization "None"
For Technological Functions
— Parameterizable Yes
Cable Length
Shielded, Max. 150 M
Encoder
Connectable Encoders
Incremental Encoder (Symmetrical) Yes; Up To 200 Khz Depending On Cable Type And Length
Encoder Signals, Incremental Encoder (Symmetrical)
Input Voltage 1 Vpp, Centered At 2.5 V Offset
Input Frequency, Max. 200 Khz
Counting Frequency, Max. 800 Khz; With Quadruple Evaluation
Cable Length, Shielded, Max. 150 M
Incremental Encoder With A/B Tracks, 90° Phase Offset Yes; Sin/Cos
Incremental Encoder With A/B Tracks, 90° Phase Offset
And Zero Trackyes; Sin/Cos/Zero
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; See Chapter "Diagnostic Messages" In The Manual
Alarms
Diagnostic Alarm Yes
Hardware Interrupt No
Diagnoses
Monitoring The Supply Voltage Yes
Wire-Break Yes
Short-Circuit Yes
A/B Transition Error At Incremental Encoder Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Module Diagnostics Yes; Green/Red Diag Led
Integrated Functions
Counter Yes
Number Of Counters 1
Counting Frequency, Max. 800 Khz; With Quadruple Evaluation
Safety Monitoring Functions
Safe Operating Stop (Sos) Yes
Safely-Limited Speed (Sls) Yes
Safe Direction (Sdi) Yes
Safe Speed Monitor (Ssm) Yes
Counting Functions
Continuous Counting Yes
Counter Response Parameterizable Yes
Software Gate Yes
Counting Range, Parameterizable Yes

Measuring Functions

Measuring Range
— Frequency Measurement, Min. 0.04 Hz
— Frequency Measurement, Max. 800 Khz; With Quadruple Evaluation
— Cycle Duration Measurement, Min. 1 Μs
— Cycle Duration Measurement, Max. 25 S
— Velocity Measurement, Min. 0 (Speed In Configured Units Per Selected Time Basis - Speed*1 000)
— Velocity Measurement, Max. 2 147 483 (Speed In Configured Units Per Selected Time Basis - Speed*1 000)
Accuracy
— Frequency Measurement Up To 100 Ppm; Depending On Measuring Interval And Signal Evaluation; At Low
Frequency External Noise May Have An Effect On Accuracy (Reference The Graph
In 2.2.3)
— Cycle Duration Measurement Up To 100 Ppm; Depending On Measuring Interval And Signal Evaluation; At Low
Frequency External Noise May Have An Effect On Accuracy (Reference The Graph
In 2.2.3)
— Velocity Measurement Up To 100 Ppm; Depending On Measuring Interval And Signal Evaluation; At Low
Frequency External Noise May Have An Effect On Accuracy (Reference The Graph
In 2.2.3)
Potential Separation
Potential Separation Channels
Between The Channels No; Only One Channel Is Available
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ No
Between The Channels And The Power Supply Of The
Electronicsno
Isolation
Isolation Tested With 707 V Dc (Type Test)
Standards, Approvals, Certificates
Suitable For Safety Functions Yes
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 88.3 Kg
— Global Warming Potential, (During Production) [Co2
Eq]13.1 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]76.6 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-1.37 Kg
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Cat. 4, Ple
Sil Acc. To Iec 61508 Sil 3
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With Sil1 < 2.00E-03 Signal Monitoring Disabled
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 3.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil1< 3.00E-08 1/H Signal Monitoring Disabled
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 1.00E-09 1/H

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 55 °C
Altitude During Operation Relating To Sea Level
Ambient Air Temperature-Barometric Pressure-Altitude On Request: Installation Altitudes Greater Than 2 000 M

Dimensions

Width 15 Mm
Height 73 Mm
Depth 58 Mm
Weight S