This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7142-5AF00-0BL0

6ES7142-5AF00-0BL0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7142-5AF00-0BL0 Siemens

6ES7142-5AF00-0BL0 Siemens - SIMATIC ET 200AL, IO-Link, DQ 8x 24 V DC/2 A, 8x M12, Degree of protection IP67

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£115.96 Exc. VAT
£139.15 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7142-5AF00-0BL0
Product Description SIMATIC ET 200AL, IO-Link, DQ 8x 24 V DC/2 A, 8x M12, Degree of protection IP67
Product family IO-Link I/O modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,193 Kg
Packaging Dimension 5,50 x 17,80 x 5,50
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623411390
UPC 195125114722
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group X03V
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 03.08.2020
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage 1L+
Rated Value (Dc) 24 V; Supply From 1Us+ Of The Io-Link Master
Permissible Range, Lower Limit (Dc) 18 V
Permissible Range, Upper Limit (Dc) 30 V
Reverse Polarity Protection Yes; Against Destruction
Load Voltage 2L+
Rated Value (Dc) 24 V; Supply Via M12 Connector L-Coded
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes; Against Destruction; Load Increasing
Input Current
Current Consumption (Rated Value) 12 Ma; Without Load
From Load Voltage 2L+, Max. 8 A; Maximum Value
Power Loss
Power Loss , Typ. 3.6 W
Digital Outputs
Number Of Digital Outputs 8
Output Characteristic Acc. To Iec 61131, Type 2 Yes
Short-Circuit Protection Yes; Per Channel, Electronic
Response Threshold, Typ. 2.8 A
Limitation Of Inductive Shutdown Voltage To 2L+ (-47 V)
Switching Capacity Of The Outputs
On Lamp Load, Max. 10 W
Load Resistance Range
Lower Limit 12 Ω
Upper Limit 4 Kω
Output Voltage
For Signal "1", Min. L+ (-0.8 V)
Output Current
For Signal "1" Rated Value 2 A (45 °C); 1 A (55 °C)
For Signal "1" Permissible Range, Max. 2 A; With Inductive Load To Iec 60947-5-1, Dc-13 / Ac-15
For Signal "0" Residual Current, Max. 0.5 Ma
Switching Frequency
With Resistive Load, Max. 100 Hz
With Inductive Load, Max. 0.1 Hz; 0.25 Hz At 25 °C
On Lamp Load, Max. 1 Hz
Total Current Of The Outputs
Current Per Module, Max. 8 A
Cable Length
Unshielded, Max. 30 M
Io-Link
Io-Link Protocol 1.1 Yes
Transmission Rate 38.4 Kbd (Com2)
Cycle Time, Min. 2.1 Ms
Size Of Process Data, Input Per Module 0 Byte
Size Of Process Data, Output Per Module 1 Byte
Supported Io-Link Profiles Common Profile
Cable Length Unshielded, Max. 20 M
Connection Of Io-Link Devices
Port Type A Yes
Interrupts/Diagnostics/Status Information
Substitute Values Connectable Yes; Channel By Channel, Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnoses
Short-Circuit Yes; Outputs To Ground; Module By Module
Diagnostics Indication Led
Channel Status Display Yes; Green Led
For Module Diagnostics Yes; Green/Red Led
For Load Voltage Monitoring Yes; Green Led
Potential Separation
Between The Load Voltages Yes
Potential Separation Channels
Between The Channels No
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Isolation Tested With 707 V Dc (Type Test)
Degree And Class Of Protection
Ip Degree Of Protection Ip65/67
Standards, Approvals, Certificates
Suitable For Safety-Related Tripping Of Standard Modules Yes; From Fs01
Highest Safety Class Achievable For Safety-Related Tripping Of Standard Modules
Performance Level According To Iso 13849-1 Pl D
Category According To Iso 13849-1 Cat. 3
Sil Acc. To Iec 62061 Sil 2
Remark On Safety-Oriented Shutdown Https://Support.Industry.Siemens.Com/Cs/De/En/View/39198632

Ambient Temperature During Operation

Min. -30 °C
Max. 55 °C
Connection Method
Design Of Electrical Connection For The Inputs And Outputs M12, 5-Pin, A-Coded
Type Of Electrical Connection For Io-Link M12, 5-Pin, A-Coded
Design Of Electrical Connection For Supply Voltage M12, 4-Pin, L-Coded

Dimensions

Width 45 Mm
Height 159 Mm
Depth 45 Mm
Weight S
Weight , Approx. 168 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible