Description for 6ES7142-6BR00-0BB0 Siemens

6ES7142-6BR00-0BB0 Siemens - SIMATIC ET 200eco PN, DQ 8x 24 V DC/2A, M12-L, 8x M12, single and double assignment, source output (PNP,switching to P potential), substitute value output, channel diagnostics for wire break and short-circuit at the output, shared device with 2 controllers, 0.25 ms isochronous mode, prioritized startup, MSO, MRP, S2 redundancy, I&M0...3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP67 / IP69K

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£329.94 Exc. VAT
£395.93 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7142-6BR00-0BB0
Product Description SIMATIC ET 200eco PN, DQ 8x 24 V DC/2A, M12-L, 8x M12, single and double assignment, source output (PNP,switching to P potential), substitute value output, channel diagnostics for wire break and short-circuit at the output, shared device with 2 controllers, 0.25 ms isochronous mode, prioritized startup, MSO, MRP, S2 redundancy, I&M0...3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP67 / IP69K
Product family Digital I/O devices
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,805 Kg
Packaging Dimension 6,00 x 22,40 x 5,50
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623410911
UPC 195125075399
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group X00R
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2019
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Isochronous Mode Yes
Prioritized Startup Yes
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version Step 7 V17 Or Higher With Hsp 0363
Profinet From Gsd Version/Gsd Revision Gsdml V2.3.X
Multi Fieldbus Configuration Tool (Mfct) From V1.3 Sp1
Operating Mode
Dq Yes
Mso Yes

Supply Voltage

Power Supply According To Nec Class 2 Required No
Load Voltage 1L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Load Voltage 2L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes; Against Destruction
Input Current
Current Consumption (Rated Value) 65 Ma; Without Load
From Load Voltage 1L+ (Unswitched Voltage) 12 A; Maximum Value
From Load Voltage 2L+, Max. 12 A; Maximum Value
Power Loss
Power Loss , Typ. 8.2 W
Address Area
Address Space Per Module
Inputs 1 Byte For Qi Information
Outputs 1 Byte
Hardware Configuration
Submodules
Number Of Configurable Submodules, Max. 2
Digital Outputs
Number Of Digital Outputs 8
Current-Sourcing Yes
Output Characteristic Acc. To Iec 61131, Type 2 Yes
Short-Circuit Protection Yes; Per Channel, Electronic
Response Threshold, Typ. 4 A
Limitation Of Inductive Shutdown Voltage To Type -14 V
Control Ling A Digital Input Yes
Switching Capacity Of The Outputs
With Resistive Load, Max. 2 A
With Inductive Load, Max. 2 A
On Lamp Load, Max. 10 W
Load Resistance Range
Lower Limit 12 Ω
Upper Limit 4 Kω
Output Voltage
For Signal "1", Min. 2L+ (-0,8 V)
Output Current
For Signal "1" Rated Value 2 A
For Signal "1" Permissible Range, Max. 2 A
For Signal "0" Residual Current, Max. 0.2 Ma
Output Delay With Resistive Load
"0" To "1", Max. 50 Μs; At Rated Load
"1" To "0", Max. 100 Μs; At Rated Load
Parallel Switching Of Two Outputs
For Uprating No
For Redundant Control Of A Load Yes
Switching Frequency
With Resistive Load, Max. 100 Hz
With Inductive Load, Max. 0.5 Hz
On Lamp Load, Max. 1 Hz
Total Current Of The Outputs
Current Per Module, Max. 8 A
Cable Length
Unshielded, Max. 30 M
Interfaces
Number Of Profinet Interfaces 1
1. Interface
Interface Type Profinet With 100 Mbit/S Full Duplex (100Base-Tx)
Interface Types
M12 Port Yes; 2X M12, 4-Pin, D-Coded
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Device Yes
Open Ie Communication Yes
Interface Types
M12 Port
Autonegotiation Yes
Autocrossing Yes
Transmission Rate, Max. 100 Mbit/S
Protocols
Supports Protocol For Profinet Io Yes
Profisafe No
Ethernet /Ip Yes
Modbus Tcp Yes
Profinet Io Device
Services
— Irt Yes; 250 Μs To 4 Ms In 125 Μs Frame
— Prioritized Startup Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Redundancy Mode
Profinet System Redundancy (S2) Yes
— On S7-1500R/H Yes
— On S7-400H Yes
Profinet System Redundancy (R1) No
H-Sync Forwarding Yes
Media Redundancy
— Mrp Yes
Ethernet /Ip
Services
— Cip Implicit Messaging Yes
— Cip Explicit Messaging Yes
— Cip Safety No
— Shared Device Yes; 2X Ethernet/Ip Scanner
— Number Of Scanners With Shared Device, Max. 2
Updating Times
— Requested Packet Interval (Rpi) 2 Ms
Redundancy Mode
— Dlr (Device Level Ring) No
Address Area
— Address Space Per Module, Max. 20 Byte
— Largeforwardopen (Class3) No
Modbus Tcp
Services
— Read Coils (Code=1) Yes
— Read Discrete Inputs (Code=2) Yes
— Read Holding Registers (Code=3) Yes
— Write Single Coil (Code=5) Yes
— Write Multiple Coils (Code=15) Yes
— Write Multiple Registers (Code=16) Yes
— Parameter Change By Master No
— Modbus Tcp Security Protocol No
Address Space Per Station
— Address Space Per Station, Max. 20 Byte
— Access-Consistent Address Space 2 Byte
Updating Time
— I/O Request Interval 2 Ms

Connections

— Number Of Connections Per Device 12
Open Ie Communication
Tcp/Ip Yes; (Only Ethernet/Ip Or Modbus Tcp)
Snmp Yes
Lldp Yes
Arp Yes
Isochronous Mode
Equidistance Yes
Shortest Clock Pulse 250 Μs
Max. Cycle 4 Ms
Jitter, Max. 10 Μs
Interrupts/Diagnostics/Status Information
Substitute Values Connectable Yes
Alarms
Diagnostic Alarm Yes; Parameterizable
Maintenance Interrupt Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes
Monitoring The Supply Voltage Yes
— Parameterizable Yes
Wire-Break Yes
Short-Circuit Yes; Outputs To M; Channel By Channel
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Maint Led Yes; Yellow Led
Ns Led Yes; Green/Red Led
Ms Led Yes; Green/Red Led
Io Led Yes; Red/Green/Yellow Leds
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Load Voltage Monitoring Yes; Green Led
Connection Display Link Tx/Rx Yes; Green Led, Only Link
Potential Separation
Between The Load Voltages Yes
Between Ethernet And Electronics Yes
Potential Separation Channels
Between The Channels No
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Tested With
24 V Dc Circuits 707 V Dc (Type Test)
Test Voltage For Interface, Rms Value [Vrms] 1 500 V; According To Ieee 802.3
Degree And Class Of Protection
Ip Degree Of Protection Ip65/67/69K
Standards, Approvals, Certificates
Suitable For Safety-Related Tripping Of Standard Modules Yes; From Fs02
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 63 Kg
— Global Warming Potential, (During Production) [Co2
Eq]12.7 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]52.8 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-2.65 Kg
Highest Safety Class Achievable For Safety-Related Tripping Of Standard Modules
Performance Level According To Iso 13849-1 Pl D
Category According To Iso 13849-1 Cat. 3
Sil Acc. To Iec 62061 Sil 2
Remark On Safety-Oriented Shutdown Https://Support.Industry.Siemens.Com/Cs/De/En/View/39198632
Use In Hazardous Areas
Explosion Protection Category For Gas Atex, Ukex, Iecex, Cccex For Zone 2
Explosion Protection Category For Dust Atex, Ukex, Iecex, Cccex For Zone 22
Product Functions / Security / Header
Signed Firmware Update Yes
Safely Removing Data Yes

Ambient Temperature During Operation

Min. -40 °C
Max. 60 °C
Altitude During Operation Relating To Sea Level
Ambient Air Temperature-Barometric Pressure-Altitude Up To Max. 5 000 M, At Installation Height > 2 000 M Additional Restrictions
Connection Method
Design Of Electrical Connection 4/5-Pin M12 Circular Connectors
Design Of Electrical Connection For The Inputs And Outputs M12, 5-Pin, A-Coded
Design Of Electrical Connection For Supply Voltage M12, 4-Pin, L-Coded

Dimensions

Width 45 Mm
Height 200 Mm
Depth 48 Mm
Weight S
Weight , Approx. 780 G