This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7144-4GF01-0AB0

6ES7144-4GF01-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7144-4GF01-0AB0 Siemens

6ES7144-4GF01-0AB0 Siemens - MODULE, ET200PRO, 4AI, 20MA, CH

Extended Description for 6ES7144-4GF01-0AB0 Siemens

6ES7144-4GF01-0AB0 Siemens - SIMATIC dp, electronic module for et200pro 4 ai i high feature, +-20ma 0...20ma 4-20ma channel diagnostics inclusive bus module connecting module io 6ES7194-4..00-0aa0 must be ordered seperately

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£217.50 Exc. VAT
£261.00 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7144-4GF01-0AB0
Product Description SIMATIC DP, Electronic module for ET 200 PRO 4 AI I High Feature, +-20 mA; 0...20 mA; 4-20mA; Channel diagnostics; incl. bus module, Connection module IO 6ES7194-4..00-0AA0 order separately
Product family Analog expansion modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,178 Kg
Packaging Dimension 7,30 x 13,70 x 6,50
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623403234
UPC 887621775872
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group 4057
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.10.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Reverse Polarity Protection Yes; Against Destruction
Input Current
From Supply Voltage 1L+, Max. 40 Ma; Typical
From Backplane Bus 3.3 V Dc, Max. 12 Ma; Typical
Encoder Supply
Number Of Outputs 4
Short-Circuit Protection Yes; Per Module, Electronic To Frame
Output Current
Up To 55 °C, Max. 1 A
Power Loss
Power Loss , Typ. 1.1 W
Address Area
Address Space Per Module
Address Space Per Module, Max. 8 Byte

Analog Inputs

Number Of Analog Inputs 4
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Cycle Time (All Channels) Max. 10 Ms
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 50 Ω
-20 Ma To +20 Ma Yes
— Input Resistance (-20 Ma To +20 Ma) 50 Ω
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 50 Ω
Cable Length
Shielded, Max. 30 M
Analog Value Generation For The Inputs
Measurement Principle Integrating
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 15 Bit; 15 Bit + Sign At ±10 V, At ±5 V; 15 Bit At 0 V To 10 V, At 1 V To 5 V
Integration Time (Ms) 0,3 / 16,7 / 20 / 60
Interference Voltage Suppression For Interference
Frequency F1 In Hz16,67 / 50 / 60 / 3 600
Conversion Time (Per Channel) 1.1 Ms
Smoothing Of Measured Values
Parameterizable Yes
Step: None Yes; 1X Cycle Time
Step: Low Yes; 4X Cycle Time
Step: Medium Yes; 16X Cycle Time
Step: High Yes; 64X Cycle Time
Encoder
Connection Of Signal Encoders
For Current Measurement As 2-Wire Transducer Yes
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Linearity Error (Relative To Input Range), (+/-) 0.0075 %
Temperature Error (Relative To Input Range), (+/-) 0.00075 %/K
Crosstalk Between The Inputs, Min. -70 Db
Repeat Accuracy In Steady State At 25 °C (Relative To Input
Range), (+/-)0.004 %
Operation Al Error Limit In Overall Temperature Range
Current, Relative To Input Range, (+/-) 0.1 %
Basic Error Limit (Operational Limit At 25 °C)
Current, Relative To Input Range, (+/-) 0.075 %
Interference Voltage Suppression For F = N X (F1 +/- 0.5 %), F1 = Interference Frequency
Series Mode Interference (Peak Value Of Interference <
Rated Value Of Input Range), Min.60 Db
Common Mode Interference (Uss < 2.5 V), Min. 80 Db; Interference Voltage < 5 V
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes; Parameterizable
Hardware Interrupt Yes; (Limit Value Alarm), Can Be Parameterized For Channel 0
Diagnoses
Diagnostic Information Readable Yes
Wire-Break Yes; At 4 To 20 Ma
Short-Circuit Yes; At 4 To 20 Ma
Diagnostics Indication Led
Group Error Sf (Red) Yes
Potential Separation
Potential Separation Analog Inputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Permissible Potential Difference
Between The Inputs And Mana (Ucm) 5 Vpp Ac
Isolation
Isolation Tested With 707 V Dc (Type Test)

Dimensions

Width 45 Mm
Height 130 Mm
Depth 35 Mm
Weight S
Weight , Approx. 150 G