Description for 6ES7147-5JD00-0BA0 Siemens

6ES7147-5JD00-0BA0 Siemens - SIMATIC ET 200AL, CM 4X IO-LINK, 4XM12

Extended Description for 6ES7147-5JD00-0BA0 Siemens

6ES7147-5JD00-0BA0 Siemens - SIMATIC et 200al, cm 4x io-link, 4xm12, degree of protection IP67

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£241.07 Exc. VAT
£289.28 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7147-5JD00-0BA0
Product Description SIMATIC ET 200AL, CM 4x IO-Link, 4x M12, Degree of protection IP67
Product family CM IO-Link
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,169 Kg
Packaging Dimension 4,50 x 17,60 x 4,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623403531
UPC 804766168147
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group X089
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 04.09.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version Step 7 V13 Sp1 Or Higher
Step 7 Configurable/Integrated From Version From V5.5 Sp4 Hotfix 3
Profibus From Gsd Version/Gsd Revision Gsd As Of Revision 5
Profinet From Gsd Version/Gsd Revision Gsdml V2.3.1

Supply Voltage

Power Supply According To Nec Class 2 Required No
Load Voltage 1L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Load Voltage 2L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes; Against Destruction; Load Increasing
Input Current
Current Consumption (Rated Value) 40 Ma; Without Load
From Load Voltage 1L+ (Unswitched Voltage) 4 A; Maximum Value
From Load Voltage 2L+, Max. 4 A; Maximum Value
Encoder Supply
Number Of Outputs 4
24 V Encoder Supply
Short-Circuit Protection Yes; Per Module, Electronic
Output Current, Max. 1.4 A; Total Current Of All Ports
Power Loss
Power Loss , Typ. 2.6 W
Io-Link
Number Of Ports 4
Of Which Simultaneously Controllable 4
Io-Link Protocol 1.0 Yes
Io-Link Protocol 1.1 Yes
Transmission Rate 4.8 Kbaud (Com1); 38.4 Kbaud (Com2), 230 Kbaud (Com3)
Size Of Process Data, Input Per Port 32 Byte
Size Of Process Data, Input Per Module 132 Byte
Size Of Process Data, Output Per Port 32 Byte
Size Of Process Data, Output Per Module 128 Byte
Memory Size For Device Parameter 2 Kbyte; For Each Port
Master Backup Possible With Function Block Io_Link_Master
Configuration Without S7-Pct Possible; Autostart/Manual Function
Cable Length Unshielded, Max. 20 M
Operating Modes
Io-Link Yes
Di Yes
Dq Yes; Max. 100 Ma
Connection Of Io-Link Devices
Port Type A Yes; Via 3-Core Cable
Port Type B Yes; Additional Device Supply: 1.6 A Total Current Of All Ports
Interrupts/Diagnostics/Status Information
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnoses
Monitoring The Supply Voltage Yes
Wire-Break Yes
Short-Circuit Yes
Diagnostics Indication Led
Channel Status Display Yes; Green Led
For Module Diagnostics Yes; Green/Red Led
For Load Voltage Monitoring Yes; Green Led
Potential Separation
Between The Load Voltages Yes
Potential Separation Channels
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsno
Isolation
Isolation Tested With 707 V Dc (Type Test)
Degree And Class Of Protection
Ip Degree Of Protection Ip65/67
Standards, Approvals, Certificates
Suitable For Safety-Related Tripping Of Standard Modules Yes; From Fs01
Highest Safety Class Achievable For Safety-Related Tripping Of Standard Modules
Performance Level According To Iso 13849-1 Pl D
Category According To Iso 13849-1 Cat. 3
Silcl According To Iec 62061 Silcl 2

Ambient Temperature During Operation

Min. -30 °C
Max. 55 °C
Connection Method
Design Of Electrical Connection For The Inputs And Outputs M12, 5-Pole
Design Of Electrical Connection For Supply Voltage M8, 4-Pole
Et-Connection
Et-Connection M8, 4-Pin, Shielded

Dimensions

Width 30 Mm
Height 159 Mm
Depth 40 Mm
Weight S
Weight , Approx. 145 G

Documentation