This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7148-6JD00-0AB0

6ES7148-6JD00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7148-6JD00-0AB0 Siemens

6ES7148-6JD00-0AB0 Siemens - ET 200eco PN: IO-Link Master

Extended Description for 6ES7148-6JD00-0AB0 Siemens

6ES7148-6JD00-0AB0 Siemens - SIMATIC DP. ET 200eco PN. IO-Link master. 4IO-L. 4 x M12. degree of protection IP67

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£452.30 Exc. VAT
£542.76 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7148-6JD00-0AB0
Product Description SIMATIC DP, ET 200eco PN, IO-Link master, 4IO-L, 4xM12, Degree of protection IP67
Product family IO-Link master
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2024

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,631 Kg
Packaging Dimension 6,00 x 21,50 x 3,40
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623406006
UPC 804766342356
Commodity Code 85389091
LKZ_FDB/ CatalogID ST76
Product Group X08F
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 12.08.2016
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Power Supply According To Nec Class 2 Required Yes
Load Voltage 2L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes; Against Destruction; Load Increasing
Input Current
Current Consumption, Typ. 100 Ma
From Supply Voltage 1L+, Max. 4 A
From Load Voltage 2L+, Max. 4 A
Encoder Supply
Number Of Outputs 4
24 V Encoder Supply
Short-Circuit Protection Yes; Per Channel, Electronic
Output Current, Max. 500 Ma; Per Channel
Power Loss
Power Loss , Typ. 4.8 W
Io-Link
Number Of Ports 4
Of Which Simultaneously Controllable 4
Io-Link Protocol 1.0 Yes
Io-Link Protocol 1.1 Yes
Transmission Rate 4.8 Kbaud (Com1); 38.4 Kbaud (Com2), 230 Kbaud (Com3)
Size Of Process Data, Input Per Port 32 Byte
Size Of Process Data, Input Per Module 128 Bytes + 4 Bytes Pqi
Size Of Process Data, Output Per Port 32 Byte
Size Of Process Data, Output Per Module 128 Byte
Memory Size For Device Parameter 2 Kbyte; For Each Port
Master Backup Possible With Function Block Io_Link_Master
Configuration Without S7-Pct Possible; Autostart/Manual Function
Cable Length Unshielded, Max. 20 M
Operating Modes
Io-Link Yes
Di Yes
Dq Yes; Max. 100 Ma
Connection Of Io-Link Devices
Port Type A Yes; Via 3-Core Cable
Port Type B Yes; Additional Device Supply: Max. 2 A Per Port, Max. 4 A Per Module
Interfaces
Transmission Procedure 100Base-Tx
Number Of Profinet Interfaces 1
1. Interface
Interface Types
M12 Port Yes
Integrated Switch Yes
Interface Types
M12 Port
Autonegotiation Yes
Autocrossing Yes
Transmission Rate, Max. 100 Mbit/S
Protocols
Supports Protocol For Profinet Io Yes
Profinet Cba No
Profisafe No
Ethernet /Ip No
Profinet Io Device
Services
— Irt With The Option "High Flexibility" Yes
Redundancy Mode
Media Redundancy
— Mrp Yes
Open Ie Communication
Tcp/Ip No
Snmp Yes
Dcp Yes
Lldp Yes
Ping Yes
Arp Yes
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Diagnostic Information Readable Yes
Monitoring The Supply Voltage Yes; Green "On" Led
Short-Circuit Yes; Device Supply To M
Group Error Yes; Red/Yellow "Sf/Mt" Led
Potential Separation
Between The Load Voltages Yes
Between Load Voltage And All Other Switching Components No
Between Ethernet And Electronics Yes
Isolation
Tested With
24 V Dc Circuits 707 V Dc (Type Test)
Test Voltage For Interface, Rms Value [Vrms] 1 500 V; According To Ieee 802.3
Degree And Class Of Protection
Ip Degree Of Protection Ip65/67
Standards, Approvals, Certificates
Suitable For Safety-Related Tripping Of Standard Modules No
Use In Hazardous Areas
Explosion Protection Category For Gas Atex Ii 3G Ex Na Ii T4
Explosion Protection Category For Dust Atex Ii 3D Ex Tc Iiic T90°C Dc
Connection Method
Design Of Electrical Connection 3/5-Pin M12 Round Connectors

Dimensions

Width 30 Mm
Height 200 Mm
Depth 49 Mm
Weight S
Weight , Approx. 550 G

Documentation

Looking for a specific part?