Siemens

6ES7211-0AA23-0XB0

6ES7211-0AA23-0XB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7211-0AA23-0XB0 Siemens

6ES7211-0AA23-0XB0 Siemens - *** spare part *** SIMATIC S7-200, CPU 221 Compact unit, DC power supply 6 DI DC/4 DO DC 4 KB progr./2 KB data

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7211-0AA23-0XB0
Product Description *** spare part *** SIMATIC S7-200, CPU 221 Compact unit, DC power supply 6 DI DC/4 DO DC 4 KB progr./2 KB data
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 18.01.2022
Notes This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,239 Kg
Packaging Dimension 10,00 x 11,10 x 7,60
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515071105
UPC 662643188837
Commodity Code 85371091
LKZ_FDB/ CatalogID ST9-E5
Product Group 4255
Group Code R131
Country of origin China
Compliance with the substance restrictions according to RoHS directive Since: 31.03.2008
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc)
24 V Dc Yes
Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
Inrush Current, Max. 10 A; At 28.8 V
From Supply Voltage L+, Max. 450 Ma; 80 To 450 Ma
Encoder Supply
24 V Encoder Supply
24 V Yes; Permissible Range: 15.4 To 28.8 V
Short-Circuit Protection Yes; Electronic At 600 Ma
Output Current, Max. 180 Ma
Power Loss
Power Loss , Typ. 3 W
Memory
Number Of Memory Modules (Optional) 1; Pluggable Memory Module, Content Identical With Integral Eeprom; Can
Additionally Store Recipes, Data Logs And Other Files
Work Memory
Integrated (For Program) 4 Kbyte
Integrated (For Data) 2 Kbyte
Backup
Present Yes; Program: Entire Program Maintenance-Free On Integral Eeprom,
Programmable Via Cpu; Data: Entire Db 1 Loaded From Pg/Pc Maintenance-
Free On Integral Eeprom, Current Values Of Db 1 In Ram, Retentive Memory
Bits, Timers, Counters, Etc. Maintenance-Free Via High-Performance Capacitor;
Optional Battery For Long-Term Buffering
Battery
Backup Battery
Backup Time, Max. 50 H; (Min. 8 H At 40 °C); 200 Days (Typ.) With Optional Battery Module
Cpu Processing Times
For Bit Operations, Max. 0.22 Μs
Counters, Timers And Their Retentivity
S7 Counter
Number 256
Retentivity
— Adjustable Yes; Via High-Performance Capacitor Or Battery
Counting Range
— Lower Limit 0
— Upper Limit 32 767
S7 Times
Number 256
Retentivity
— Adjustable Yes; Via High-Performance Capacitor Or Battery
Time Range
— Lower Limit 1 Ms
— Upper Limit 54 Min; 4 Timers: 1 Ms To 30 S; 16 Timers: 10 Ms To 5 Min; 236 Timers: 100 Ms To
54 Min
Data Areas And Their Retentivity
Flag
Size, Max. 32 Byte
Retentivity Available Yes; M 0.0 To M 31.7
Of Which Retentive With Battery 0 To 255, Via High-Performance Capacitor Or Battery, Adjustable
Of Which Retentive Without Battery 0 To 112 In Eeprom, Adjustable
Hardware Configuration
Connectable Programming Devices/Pcs Simatic Pg/Pc, Standard Pc
Digital Inputs
Number Of Digital Inputs 6; Integrated
Source/Sink Input Yes; Optionally, Per Group
Input Voltage
Rated Value (Dc) 24 V
For Signal "0" 0 To 5 V
For Signal "1" Min. 15 V
Input Current
For Signal "1", Typ. 2.5 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable Yes; All
— At "0" To "1", Min. 0.2 Ms
— At "0" To "1", Max. 12.8 Ms
For Interrupt Inputs
— Parameterizable Yes; I 0.0 To I 0.3
For Technological Functions
— Parameterizable Yes; (E 0.0 To E 0.5) 30 Khz
Cable Length
Shielded, Max. 500 M; Standard Input: 500 M, High-Speed Counters: 50 M
Unshielded, Max. 300 M; Not For High-Speed Signals
Digital Outputs
Number Of Digital Outputs 4; Transistor
Short-Circuit Protection No; To Be Provided Externally
Limitation Of Inductive Shutdown Voltage To 1 W
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.75 A
On Lamp Load, Max. 5 W
Output Voltage
For Signal "1", Min. 20 V Dc
Output Current
For Signal "1" Rated Value 750 Ma
For Signal "0" Residual Current, Max. 0.1 Ma
Output Delay With Resistive Load
"0" To "1", Max. 15 Μs; Of The Standard Outputs, Max. (Q0.2 To Q0.3) 15 Μs; Of The Pulse Outputs,
Max. (Q0.0 To Q0.1) 2 Μs
"1" To "0", Max. 130 Μs; Of The Standard Outputs, Max. (Q0.2 To Q0.3) 100 Μs; Of The Pulse
Outputs, Max. (Q0.0 To Q0.1) 10 Μs
Parallel Switching Of Two Outputs
For Uprating Yes
Switching Frequency
Of The Pulse Outputs, With Resistive Load, Max. 20 Khz; Q0.0 To Q0.1
Total Current Of The Outputs (Per Group)
All Mounting Positions
— Up To 40 °C, Max. 3 A
Horizontal Installation
— Up To 55 °C, Max. 3 A
Relay Outputs
Number Of Relay Outputs 0
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 150 M

Analog Inputs

Number Of Analog Potentiometers 1; Analog Potentiometer; Resolution 8 Bit
Encoder
Connectable Encoders
2-Wire Sensor Yes
— Permissible Quiescent Current (2-Wire Sensor), Max. 1 Ma
1. Interface
Interface Type Integrated Rs 485 Interface
Protocols
Mpi Yes; As Mpi Slave For Data Exchange With Mpi Masters (S7-300/S7-400 Cpus,
Ops, Tds, Push Button Panels); S7-200-Internal Cpu/Cpu Communication Is
Possible In The Mpi Network With Restrictions; Transmission Rates: 19.2/187.5
Kbit/S
Ppi Yes; With Ppi Protocol For Program Functions, Hmi Functions (Td 200, Op), S7-
200-Internal Cpu/Cpu Communication ; Transmission Rates 9.6/19.2/187.5
Kbit/S
Serial Data Exchange Yes; As Freely Programmable Interface With Interrupt Facility For Serial Data
Exchange With Third-Party Devices With Ascii Protocol Transfer Rates: 1.2 / 2.4 /
4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 115.2 Kbps; The Pc/Ppi Cable Can Also Be Used As
Rs 232/Rs 485 Converter
Mpi
Transmission Rate, Min. 19.2 Kbit/S
Transmission Rate, Max. 187.5 Kbit/S
Integrated Functions
Counter
Number Of Counters 4; High-Speed Counters (30 Khz Each), 32 Bit (Incl. Sign), Can Be Used As
Up/Down Counters Or For Connecting 2 Incremental Encoders With 2 Pulse Trains
Offset By 90° (Max. 20 Khz (A/B Counters)); Parameterizable Enable And Reset
Input; Interrupt Facilities (Incl. Call Of Subroutine With Any Content) When The
Setpoint Is Reached; Reversal In Counting Direction, Etc.
Counting Frequency, Max. 30 Khz
Number Of Alarm Inputs 4; 4 Rising Edges And/Or 4 Falling Edges
Number Of Pulse Outputs 2; High-Speed Outputs, 20 Khz, With Interrupt Option; Pulse-Width And Frequency
Modulation Option
Limit Frequency (Pulse) 20 Khz
Potential Separation
Potential Separation Digital Inputs
Between The Channels Yes
Between The Channels, In Groups Of 2 And 4
Potential Separation Digital Outputs
Between The Channels Yes; Optocoupler
Between The Channels, In Groups Of 4
Permissible Potential Difference
Between Different Circuits 500 V Dc Between 24 V Dc And 5 V Dc
Degree And Class Of Protection
Ip Degree Of Protection Ip20

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 55 °C
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 45 °C
Air Pressure Acc. To Iec 60068-2-13
Permissible Range, Lower Limit 860 Hpa
Permissible Range, Upper Limit 1 080 Hpa
Relative Humidity
Operation, Min. 5 %
Operation, Max. 95 %; Rh Class 2 In Accordance With Iec 1131-2
Configuration / Header
Configuration / Programming / Header
Command Set Bit Logic Instructions, Compare Instructions, Timer Instructions, Counter
Instructions, Clock Instructions, Transmissions Instructions, Table Instructions,
Logic Instructions, Shift And Rotate Instructions, Conversion Instructions, Program
Control Instructions, Interrupt And Communications Instructions, Logic Stack
Instructions, Integer Maths, Floating-Point Math Instructions, Numerical Functions
Program Processing Free Cycle (Ob 1), Interrupt-Controller, Time-Controlled (1 To 255 Ms)
Program Organization 1 Ob, 1 Db, 1 Sdb Subroutines With/Without Parameter Transfer
Number Of Subroutines, Max. 64
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
Know-How Protection
User Program Protection/Password Protection Yes; 3-Stage Password Protection
Connection Method
Plug-In I/O Terminals No

Dimensions

Width 90 Mm
Height 80 Mm
Depth 62 Mm
Weight S
Weight , Approx. 270 G

Documentation