This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7211-1AE40-0XB0

6ES7211-1AE40-0XB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7211-1AE40-0XB0 Siemens

6ES7211-1AE40-0XB0 Siemens - CPU 1211C, DC/DC/DC, 6DI/4DO/2AI

Extended Description for 6ES7211-1AE40-0XB0 Siemens

6ES7211-1AE40-0XB0 Siemens - SIMATIC s7-1200, cpu 1211c, compact cpu, DC/DC/DC, onboard i/o 6 di 24V DC 4 do 24 V DC 2 ai 0 - 10V DC, power supply DC 20.4 - 28.8 V DC, program/data memory 30 kb

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7211-1AE40-0XB0
Product Description SIMATIC S7-1200, CPU 1211C, compact CPU, DC/DC/DC, onboard I/O: 6 DI 24 V DC; 4 DO 24 V DC; 2 AI 0-10 V DC, power supply: DC 20.4-28.8 V DC, program/data memory 75 KB
Product family CPU 1211C
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,292 Kg
Packaging Dimension 10,10 x 10,60 x 8,70
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623402671
UPC 887621768690
Commodity Code 85371091
LKZ_FDB/ CatalogID ST72
Product Group 4509
Group Code R132
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 12.12.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc)
24 V Dc Yes
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
Current Consumption (Rated Value) 300 Ma; Cpu Only
Current Consumption, Max. 900 Ma; Cpu With All Expansion Modules
Inrush Current, Max. 12 A; At 28.8 V Dc
I²T 0.5 A²·S
Output Current
For Backplane Bus (5 V Dc), Max. 750 Ma; Max. 5 V Dc For Cm
Encoder Supply
24 V Encoder Supply
24 V L+ Minus 4 V Dc Min.
Power Loss
Power Loss , Typ. 8 W
Memory
Work Memory
Integrated 75 Kbyte
Load Memory
Integrated 1 Mbyte
Plug-In (Simatic Memory Card), Max. With Simatic Memory Card
Backup
Present Yes
Maintenance-Free Yes
Without Battery Yes
Cpu Processing Times
For Bit Operations, Typ. 0.08 Μs; / Instruction
For Word Operations, Typ. 1.7 Μs; / Instruction
For Floating Point Arithmetic, Typ. 2.3 Μs; / Instruction
Cpu-Blocks
Number Of Blocks (Total) Dbs, Fcs, Fbs, Counters And Timers. The Maximum Number Of Addressable
Blocks Ranges From 1 To 65535. There Is No Restriction, The Entire Working
Memory Can Be Used
Ob
Number, Max. Limited Only By Ram For Code
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 14 Kbyte
Flag
Size, Max. 4 Kbyte; Size Of Bit Memory Address Area
Local Data
Per Priority Class, Max. 16 Kbyte; Priority Class 1 (Program Cycle): 16 Kb, Priority Class 2 To 26: 6 Kb
Address Area
Process Image
Inputs, Adjustable 1 Kbyte
Outputs, Adjustable 1 Kbyte
Hardware Configuration
Number Of Modules Per System, Max. 3 Communication Modules, 1 Signal Board
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Backup Time 480 H; Typical
Deviation Per Day, Max. ±60 S/Month At 25 °C
Digital Inputs
Number Of Digital Inputs 6; Integrated
Of Which Inputs Usable For Technological Functions 6; Hsc (High Speed Counting)
Source/Sink Input Yes
Number Of Simultaneously Controllable Inputs
All Mounting Positions
— Up To 40 °C, Max. 6
Input Voltage
Rated Value (Dc) 24 V
For Signal "0" 5 V Dc At 1 Ma
For Signal "1" 15 V Dc At 2.5 Ma
Input Current
For Signal "1", Typ. 4 Ma; Nominal
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 Μ S; 0.05 / 0.1 / 0.2 / 0.4 /
0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 Ms
— At "0" To "1", Min. 0.2 Ms
— At "0" To "1", Max. 12.8 Ms
For Interrupt Inputs
— Parameterizable Yes
For Technological Functions
— Parameterizable Single Phase : 3 @ 100 Khz, Differential: 3 @ 80 Khz
Cable Length
Shielded, Max. 500 M; 50 M For Technological Functions
Unshielded, Max. 300 M; For Technological Functions: No
Digital Outputs
Number Of Digital Outputs 4
Of Which High-Speed Outputs 4; 100 Khz Pulse Train Output
Limitation Of Inductive Shutdown Voltage To L+ (-48 V)
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.5 A
On Lamp Load, Max. 5 W
Output Voltage
For Signal "0", Max. 0.1 V; With 10 Kohm Load
For Signal "1", Min. 20 V
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "0" Residual Current, Max. 0.1 Ma
Output Delay With Resistive Load
"0" To "1", Max. 1 Μs
"1" To "0", Max. 5 Μs
Switching Frequency
Of The Pulse Outputs, With Resistive Load, Max. 100 Khz
Relay Outputs
Number Of Relay Outputs 0
Cable Length
Shielded, Max. 500 M
Unshielded, Max. 150 M

Analog Inputs

Number Of Analog Inputs 2
Input Ranges
Voltage Yes
Input Ranges (Rated Values), Voltages
0 To +10 V Yes
— Input Resistance (0 To 10 V) ≥100K Ohms
Cable Length
Shielded, Max. 100 M; Twisted And Shielded
Analog Outputs
Number Of Analog Outputs 0
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 10 Bit
Integration Time, Parameterizable Yes
Conversion Time (Per Channel) 625 Μs
Encoder
Connectable Encoders
2-Wire Sensor Yes
1. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 1
Integrated Switch No
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes; Optionally Also Encrypted
Web Server Yes
Media Redundancy No
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S
Services
— Pg/Op Communication Yes; Encryption With Tls V1.3 Pre-Selected
— Isochronous Mode No
— Irt No
— Profienergy No
— Prioritized Startup Yes
— Number Of Io Devices With Prioritized Startup, Max. 16
— Number Of Connectable Io Devices, Max. 16
— Number Of Connectable Io Devices For Rt, Max. 16
— Of Which In Line, Max. 16
— Activation/Deactivation Of Io Devices Yes
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Updating Time The Minimum Value Of The Update Time Also Depends On The Communication
Component Set For Profinet Io, On The Number Of Io Devices And The Quantity
Of Configured User Data.
Profinet Io Device
Services
— Pg/Op Communication Yes; Encryption With Tls V1.3 Pre-Selected
— Isochronous Mode No
— Irt No
— Profienergy Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Protocols
Supports Protocol For Profinet Io Yes
Profisafe No
Profibus Yes; Cm 1243-5 (Master) Or Cm 1242-5 (Slave) Required
Opc Ua Yes; Opc Ua Server
As-Interface Yes; Cm 1243-2 Required
Protocols (Ethernet)
Tcp/Ip Yes
Dhcp No
Snmp Yes
Dcp Yes
Lldp Yes
Redundancy Mode
Media Redundancy
— Mrp No
— Mrpd No
Simatic Communication
S7 Routing Yes
Open Ie Communication
Tcp/Ip Yes
— Data Length, Max. 8 Kbyte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes
— Data Length, Max. 8 Kbyte
Udp Yes
— Data Length, Max. 1 472 Byte
Web Server
Supported Yes
User-Defined Websites Yes
Opc Ua
Runtime License Required Yes; "Basic" License Required
Opc Ua Server Yes; Data Access (Read, Write, Subscribe), Runtime License Required
— Application Authentication Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User Authentication "Anonymous" Or By User Name & Password
— Number Of Sessions, Max. 10
— Number Of Subscriptions Per Session, Max. 5
— Sampling Interval, Min. 100 Ms
— Publishing Interval, Min. 200 Ms
— Number Of Server Methods, Max. 20
— Number Of Monitored Items, Recommended Max. 1 000
— Number Of Server Interfaces, Max. 2
— Number Of Nodes For User-Defined Server Interfaces,
Max.2 000
Further Protocols
Modbus Yes
Communication Functions / Header
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. See Online Help (S7 Communication, User Data Size)
Number Of Connections
Overall Pg Connections: 4 Reserved / 4 Max; Hmi Connections: 12 Reserved / 18 Max;
S7 Connections: 8 Reserved / 14 Max; Open User Connections: 8 Reserved / 14
Max; Web Connections: 2 Reserved / 30 Max; Opc Ua Connections: 0 Reserved
/ 10 Max; Total Connections: 34 Reserved / 64 Max
Test Commissioning Functions
Status/Control
Status/Control Variable Yes
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Forcing
Forcing Yes
Diagnostic Buffer
Present Yes
Traces
Number Of Configurable Traces 2
Memory Size Per Trace, Max. 512 Kbyte
Interrupts/Diagnostics/Status Information
Diagnostics Indication Led
Run/Stop Led Yes
Error Led Yes
Maint Led Yes
Integrated Functions
Counter
Number Of Counters 6
Counting Frequency, Max. 100 Khz
Frequency Measurement Yes
Control Led Positioning Yes
Number Of Position-Controlled Positioning Axes, Max. 8
Number Of Positioning Axes Via Pulse-Direction Interface 4; With Integrated Outputs
Pid Controller Yes
Number Of Alarm Inputs 4
Number Of Pulse Outputs 4
Limit Frequency (Pulse) 100 Khz
Potential Separation
Potential Separation Digital Inputs
Potential Separation Digital Inputs No
Between The Channels, In Groups Of 1
Potential Separation Digital Outputs
Potential Separation Digital Outputs Yes
Between The Channels No
Between The Channels, In Groups Of 1
Emc
Interference Immunity Against Discharge Of Static Electricity
Interference Immunity Against Discharge Of Static
Electricity Acc. To Iec 61000-4-2Yes
— Test Voltage At Air Discharge 8 Kv
— Test Voltage At Contact Discharge 6 Kv
Interference Immunity To Cable-Borne Interference
Interference Immunity On Supply Lines Acc. To Iec 61000-
4-4Yes
Interference Immunity On Signal Cables Acc. To Iec 61000-
4-4Yes
Interference Immunity Against Voltage Surge
Interference Immunity On Supply Lines Acc. To Iec 61000- Yes
4-5
Interference Immunity Against Conducted Variable Disturbance Induced By High-Frequency Fields
Interference Immunity Against High-Frequency Radiation
Acc. To Iec 61000-4-6Yes
Emission Of Radio Interference Acc. To En 55 011
Limit Class A, For Use In Industrial Areas Yes; Group 1
Limit Class B, For Use In Residential Areas Yes; When Appropriate Measures Are Used To Ensure Compliance With The Limits
For Class B According To En 55011
Degree And Class Of Protection
Ip Degree Of Protection Ip20
Standards, Approvals, Certificates
Ce Mark Yes
Ul Approval Yes
Culus Yes
Fm Approval Yes
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Marine Approval Yes
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 69.5 Kg
— Global Warming Potential, (During Production) [Co2
Eq]12.6 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]57.9 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-1.03 Kg

Ambient Conditions

Free Fall
Fall Height, Max. 0.3 M; Five Times, In Product Package

Ambient Temperature During Operation

Min. -20 °C
Max. 60 °C
Horizontal Installation, Min. -20 °C
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. -20 °C
Vertical Installation, Max. 50 °C
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Air Pressure Acc. To Iec 60068-2-13
Operation, Min. 795 Hpa
Operation, Max. 1 080 Hpa
Storage/Transport, Min. 660 Hpa
Storage/Transport, Max. 1 080 Hpa
Altitude During Operation Relating To Sea Level
Installation Altitude, Min. -1 000 M
Installation Altitude, Max. 5 000 M; Restrictions For Installation Altitudes > 2 000 M, See Manual
Relative Humidity
Operation, Max. 95 %; No Condensation
Vibrations
Vibration Resistance During Operation Acc. To Iec 60068-
2-62 G (M/S²) Wall Mounting, 1 G (M/S²) Din Rail
Operation, Tested According To Iec 60068-2-6 Yes
Shock Testing
Tested According To Iec 60068-2-27 Yes; Iec 68, Part 2-27 Half-Sine: Strength Of The Shock 15 G (Peak Value),
Duration 11 Ms
Pollutant Concentrations
So2 At Rh < 60% Without Condensation S02: < 0.5 Ppm; H2S: < 0.1 Ppm; Rh < 60% Condensation-Free
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes
— Fbd Yes
— Scl Yes
Know-How Protection
User Program Protection/Password Protection Yes
Copy Protection Yes
Block Protection Yes
Access Protection
Protection Of Confidential Configuration Data Yes
Protection Level: Write Protection Yes
Protection Level: Read/Write Protection Yes
Protection Level: Complete Protection Yes
Programming / Cycle Time Monitoring / Header
Adjustable Yes

Dimensions

Width 90 Mm
Height 100 Mm
Depth 75 Mm
Weight S
Weight , Approx. 370 G