This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7314-1AG14-0AB0

6ES7314-1AG14-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7314-1AG14-0AB0 Siemens

6ES7314-1AG14-0AB0 Siemens - Module CPU314, 128 KB MMCRequired

Extended Description for 6ES7314-1AG14-0AB0 Siemens

6ES7314-1AG14-0AB0 Siemens - SIMATIC S7-300, CPU 314 CPU WITH MPI INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, MICRO MEMORY CARD NECESSARY

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7314-1AG14-0AB0
Product Description SIMATIC S7-300, CPU 314 Central processing unit with MPI, Integr. power supply 24 V DC, work memory 128 KB, Micro Memory Card required
Product family CPU 314
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,315 Kg
Packaging Dimension 12,80 x 15,00 x 5,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515077695
UPC 040892550290
Commodity Code 85371091
LKZ_FDB/ CatalogID ST73
Product Group 4302
Group Code R132
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 25.11.2009
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
External Protection For Power Supply Lines (Recommendation) 2 A Min.
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Repeat Rate, Min. 1 S
Input Current
Current Consumption (Rated Value) 650 Ma
Current Consumption (In No-Load Operation), Typ. 140 Ma
Inrush Current, Typ. 3.5 A
I²T 1 A²·S
Power Loss
Power Loss , Typ. 4 W
Memory
Work Memory
Integrated 128 Kbyte
Expandable No
Load Memory
Plug-In (Mmc) Yes
Plug-In (Mmc), Max. 8 Mbyte
Data Management On Mmc (After Last Programming),
Min.10 A
Backup
Present Yes; Guaranteed By Mmc (Maintenance-Free)
Without Battery Yes; Program And Data
Cpu Processing Times
For Bit Operations, Typ. 0.06 Μs
For Word Operations, Typ. 0.12 Μs
For Fixed Point Arithmetic, Typ. 0.16 Μs
For Floating Point Arithmetic, Typ. 0.59 Μs
Cpu-Blocks
Number Of Blocks (Total) 1 024; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be
Reduced By The Mmc Used.
Db
Number, Max. 1 024; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 1 024; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 1; Ob 10
Number Of Delay Alarm Obs 2; Ob 20, 21
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs 1; Ob 40
Number Of Startup Obs 1; Ob 100
Number Of Asynchronous Error Obs 4; Ob 80, 82, 85, 87
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 16
Additional Within An Error Ob 4
Counters, Timers And Their Retentivity
S7 Counter
Number 256
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 256
Retentivity
— Adjustable Yes
— Preset No Retentivity
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 64 Kbyte
Flag
Size, Max. 256 Byte
Retentivity Available Yes; Mb 0 To Mb 255
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes; Via Non-Retain Property On Db
Retentivity Preset Yes
Local Data
Per Priority Class, Max. 32 Kbyte; Max. 2 Kb Per Block
Address Area
I/O Address Area
Inputs 1 024 Byte
Outputs 1 024 Byte
Process Image
Inputs 1 024 Byte
Outputs 1 024 Byte
Inputs, Adjustable 1 024 Byte
Outputs, Adjustable 1 024 Byte
Inputs, Default 128 Byte
Outputs, Default 128 Byte
Digital Channels
Inputs 1 024
— Of Which Central 1 024
Outputs 1 024
— Of Which Central 1 024
Analog Channels
Inputs 256
— Of Which Central 256
Outputs 256
— Of Which Central 256
Hardware Configuration
Number Of Expansion Units, Max. 3
Number Of Dp Masters
Integrated 0
Via Cp 4
Number Of Operable Fms And Cps (Recommended)
Fm 8
Cp, Ptp 8
Cp, Lan 10
Rack
Racks, Max. 4
Modules Per Rack, Max. 8
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Backup Time 6 Wk; At 40 °C Ambient Temperature
Deviation Per Day, Max. 10 S; Typ.: 2 S
Behavior Of The Clock Following Power-On Clock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup Period The Clock Continues At The Time Of Day It Had When Power Was Switched Off
Operating Hours Counter
Number 1
Number/Number Range 0
Range Of Values 0 To 2^31 Hours (When Using Sfc 101)
Granularity 1 H
Retentive Yes; Must Be Restarted At Each Restart
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
In As, Master Yes
In As, Device No
Digital Inputs
Number Of Digital Inputs 0
Digital Outputs
Number Of Digital Outputs 0

Analog Inputs

Number Of Analog Inputs 0
Interfaces
Number Of Profinet Interfaces 0
Number Of Rs 485 Interfaces 1; Mpi
Number Of Rs 422 Interfaces 0
1. Interface
Interface Type Integrated Rs 485 Interface
Isolated No
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 200 Ma
Protocols
Mpi Yes
Profibus Dp Master No
Profibus Dp Device No
Point-To-Point Connection No
Mpi
Transmission Rate, Max. 187.5 Kbit/S
Services
— Pg/Op Communication Yes
— Routing No
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes; Only Server, Configured On One Side
— S7 Communication, As Client No
— S7 Communication, As Server Yes
Protocols
Profisafe No
Communication Functions / Header
Pg/Op Communication Yes
Data Record Routing No
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 8
Number Of Gd Packets, Max. 8
Number Of Gd Packets, Transmitter, Max. 8
Number Of Gd Packets, Receiver, Max. 8
Size Of Gd Packets, Max. 22 Byte
Size Of Gd Packet (Of Which Consistent), Max. 22 Byte
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get
As Server)
S7 Communication
Supported Yes
As Server Yes
As Client Yes; Via Cp And Loadable Fb
User Data Per Job, Max. 180 Byte; With Put/Get
User Data Per Job (Of Which Consistent), Max. 240 Byte; As Server
S5 Compatible Communication
Supported Yes; Via Cp And Loadable Fc
Number Of Connections
Overall 12
Usable For Pg Communication 11
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Min. 1
— Adjustable For Pg Communication, Max. 11
Usable For Op Communication 11
— Reserved For Op Communication 1
— Adjustable For Op Communication, Min. 1
— Adjustable For Op Communication, Max. 11
Usable For S7 Basic Communication 8
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Min. 0
— Adjustable For S7 Basic Communication, Max. 8
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 12; Depending On The Configured Connections For Pg/Op And S7 Basic

Communication

Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 300
Test Commissioning Functions
Status Block Yes; Up To 2 Simultaneously
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max. 30
— Of Which Status Variables, Max. 30
— Of Which Control Variables, Max. 14
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 10
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 500
— Adjustable No
— Of Which Powerfail-Proof 100; Only The Last 100 Entries Are Retained
Number Of Entries Readable In Run, Max. 499
— Adjustable Yes; From 10 To 499
Preset 10
Service Data
Can Be Read Out Yes

Ambient Temperature During Operation

Min. 0 °C
Max. 60 °C
Configuration / Header
Configuration Software
Step 7 Yes; V5.2 Sp1 Or Higher With Hw Update
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy

Dimensions

Width 40 Mm
Height 125 Mm
Depth 130 Mm
Weight S
Weight , Approx. 280 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible