This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7317-2EK14-0AB0

6ES7317-2EK14-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7317-2EK14-0AB0 Siemens

6ES7317-2EK14-0AB0 Siemens - CPU317-2 PN/DP, 1 MB

Extended Description for 6ES7317-2EK14-0AB0 Siemens

6ES7317-2EK14-0AB0 Siemens - SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7317-2EK14-0AB0
Product Description SIMATIC S7-300 CPU 317-2 PN/DP, Central processing unit with 1 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required
Product family CPU 317-2 PN/DP
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,380 Kg
Packaging Dimension 12,80 x 15,20 x 5,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515077794
UPC 040892550337
Commodity Code 85371091
LKZ_FDB/ CatalogID ST73
Product Group 4302
Group Code R132
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 25.11.2009
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes; Via Profibus Dp Or Profinet Interface
Engineering With
Programming Package Step 7 V5.5 Or Higher

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
External Protection For Power Supply Lines (Recommendation) 2 A Min.
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Repeat Rate, Min. 1 S
Input Current
Current Consumption (Rated Value) 750 Ma
Current Consumption (In No-Load Operation), Typ. 150 Ma
Inrush Current, Typ. 4 A
I²T 1 A²·S
Power Loss
Power Loss , Typ. 4.65 W
Memory
Work Memory
Integrated 1 024 Kbyte
Expandable No
Load Memory
Plug-In (Mmc) Yes
Plug-In (Mmc), Max. 8 Mbyte
Data Management On Mmc (After Last Programming),
Min.10 A
Backup
Present Yes; Guaranteed By Mmc (Maintenance-Free)
Without Battery Yes; Program And Data
Cpu Processing Times
For Bit Operations, Typ. 0.025 Μs
For Word Operations, Typ. 0.03 Μs
For Fixed Point Arithmetic, Typ. 0.04 Μs
For Floating Point Arithmetic, Typ. 0.16 Μs
Cpu-Blocks
Number Of Blocks (Total) 2 048; (Dbs, Fcs, Fbs); The Maximum Number Of Loadable Blocks Can Be
Reduced By The Mmc Used.
Db
Number, Max. 2 048; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 2 048; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 2 048; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 1; Ob 10
Number Of Delay Alarm Obs 2; Ob 20, 21
Number Of Cyclic Interrupt Obs 4; Ob 32, 33, 34, 35
Number Of Process Alarm Obs 1; Ob 40
Number Of Dpv1 Alarm Obs 3; Ob 55, 56, 57
Number Of Isochronous Mode Obs 1; Ob 61 - Isochronous Mode Is Possible Either On Dp Or Profinet Io (Not
Simultaneously)
Number Of Startup Obs 1; Ob 100
Number Of Asynchronous Error Obs 6; Ob 80, 82, 83, 85, 86, 87 (Ob83 Only For Profinet Io)
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 16
Additional Within An Error Ob 4
Counters, Timers And Their Retentivity
S7 Counter
Number 512
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Adjustable Yes
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 512
Retentivity
— Adjustable Yes
— Preset No Retentivity
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 256 Kbyte
Flag
Size, Max. 4 096 Byte
Retentivity Available Yes; From Mb 0 To Mb 4 095
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes; Via Non-Retain Property On Db
Retentivity Preset Yes
Local Data
Per Priority Class, Max. 32 768 Byte; Max. 2048 Bytes Per Block
Address Area
I/O Address Area
Inputs 8 192 Byte
Outputs 8 192 Byte
Of Which Distributed
— Inputs 8 192 Byte
— Outputs 8 192 Byte
Process Image
Inputs 8 192 Byte
Outputs 8 192 Byte
Inputs, Adjustable 8 192 Byte
Outputs, Adjustable 8 192 Byte
Inputs, Default 256 Byte
Outputs, Default 256 Byte
Subprocess Images
Number Of Subprocess Images, Max. 1; With Profinet Io, The Length Of The User Data Is Limited To 1600 Bytes
Digital Channels
Inputs 65 536
— Of Which Central 1 024
Outputs 65 536
— Of Which Central 1 024
Analog Channels
Inputs 4 096
— Of Which Central 256
Outputs 4 096
— Of Which Central 256
Hardware Configuration
Number Of Expansion Units, Max. 3
Number Of Dp Masters
Integrated 1
Via Cp 4
Number Of Operable Fms And Cps (Recommended)
Fm 8
Cp, Ptp 8
Cp, Lan 10
Rack
Racks, Max. 4
Modules Per Rack, Max. 8
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Backup Time 6 Wk; At 40 °C Ambient Temperature
Deviation Per Day, Max. 10 S; Typ.: 2 S
Behavior Of The Clock Following Power-On Clock Continues Running After Power Off
Behavior Of The Clock Following Expiry Of Backup Period The Clock Continues At The Time Of Day It Had When Power Was Switched Off
Operating Hours Counter
Number 4
Number/Number Range 0 To 3
Range Of Values 0 To 2^31 Hours (When Using Sfc 101)
Granularity 1 H
Retentive Yes; Must Be Restarted At Each Restart
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes; With Dp Slave Only Slave Clock
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp Yes; As Client
Digital Inputs
Number Of Digital Inputs 0
Digital Outputs
Number Of Digital Outputs 0

Analog Inputs

Number Of Analog Inputs 0
Interfaces
Number Of Profinet Interfaces 1; 2 Ports (Switch) Rj45
Number Of Rs 485 Interfaces 1; Combined Mpi / Profibus Dp
Number Of Rs 422 Interfaces 0
1. Interface
Interface Type Integrated Rs 485 Interface
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 200 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device Yes
Point-To-Point Connection No
Mpi
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client No; But Via Cp And Loadable Fb
— S7 Communication, As Server Yes
Profibus Dp Master
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 124
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication Yes; I Blocks Only
— S7 Communication Yes
— S7 Communication, As Client No
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes; Ob 61; Isochronous Mode Can Only Be Used Alternatively On Profibus
Dp Or Profinet Io
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Max. Number Of Dp Devices That Can Be
Activated/Deactivated At The Same Time8
— Direct Data Exchange (Slave-To-Slave
Communication )Yes; As Subscriber
— Dpv1 Yes
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
1St Interface / Profibus Dp Device / Header
Transmission Rate, Max. 12 Mbit/S
Automatic Baud Rate Search Yes; Only With Passive Interface
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte
Services
— Pg/Op Communication Yes
— Routing Yes; Only With Active Interface
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client No
— S7 Communication, As Server Yes; Connection Configured On One Side Only
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
2. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes; 10/100 Mbit/S
Autonegotiation Yes
Autocrossing Yes
Change Of Ip Address At Runtime, Supported Yes
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 2
Integrated Switch Yes
Protocols
Mpi No
Profinet Io Controller Yes; Also Simultaneously With Io-Device Functionality
Profinet Io Device Yes; Also Simultaneously With Io Controller Functionality
Profinet Cba Yes
Profibus Dp Master No
Profibus Dp Device No
Open Ie Communication Yes; Via Tcp/Ip, Iso On Tcp, And Udp
Web Server Yes
Media Redundancy Yes
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— S7 Communication Yes; With Loadable Fbs, Max. Configurable Connections: 16, Max. Number Of
Instances: 32
— Isochronous Mode Yes; Ob 61; Isochronous Mode Can Only Be Used Alternatively On Profibus
Dp Or Profinet Io
— Irt Yes
— Shared Device Yes
— Prioritized Startup Yes
— Number Of Io Devices With Prioritized Startup, Max. 32
— Number Of Connectable Io Devices, Max. 128
— Of Which Io Devices With Irt, Max. 64
— Of Which In Line, Max. 64
— Number Of Io Devices With Irt And The Option "High
Flexibility"128
— Of Which In Line, Max. 61
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Activation/Deactivation Of Io Devices Yes
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Io Devices Changing During Operation (Partner
Ports), Supportedyes
— Number Of Io Devices Per Tool, Max. 8
— Device Replacement Without Swap Medium Yes
— Send Cycles 250 Μ S, 500 Μs,1 Ms; 2 Ms, 4 Ms (Not In The Case Of Irt With "High Flexibility"
Option)
— Updating Time 250 Μs To 512 Ms (Depending On The Operating Mode, See Manual "S7-300 Cpu
31Xc And Cpu 31X, Technical Data" For More Details)
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
— User Data Consistency, Max. 1 024 Byte
Profinet Io Device
Services
— Pg/Op Communication Yes
— Routing Yes
— S7 Communication Yes; With Loadable Fbs, Max. Configurable Connections: 16, Max. Number Of
Instances: 32
— Isochronous Mode No
— Irt Yes
— Profienergy Yes; With Sfb 73 / 74 Prepared For Loadable Profienergy Standard Fb For I-
Device
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 2
Transfer Memory
— Inputs, Max. 1 440 Byte; Per Io Controller With Shared Device
— Outputs, Max. 1 440 Byte; Per Io Controller With Shared Device
Submodules
— Number, Max. 64
— User Data Per Submodule, Max. 1 024 Byte
Profinet Cba
Acyclic Transmission Yes
Cyclic Transmission Yes
Open Ie Communication
Number Of Connections, Max. 16
Local Port Numbers Used At The System End 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
Keep-Alive Function, Supported Yes
Protocols
Profisafe No
Redundancy Mode
Media Redundancy
— Switchover Time On Line Break, Typ. 200 Ms; Profinet Mrp
— Number Of Stations In The Ring, Max. 50
Open Ie Communication
Tcp/Ip Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 16
— Data Length For Connection Type 01H, Max. 1 460 Byte
— Data Length For Connection Type 11H, Max. 32 768 Byte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 16
— Data Length, Max. 32 768 Byte
Udp Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 16
— Data Length, Max. 1 472 Byte
Web Server
Supported Yes
User-Defined Websites Yes
Number Of Http Clients 5
Communication Functions / Header
Pg/Op Communication Yes
Data Record Routing Yes
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 8
Number Of Gd Packets, Max. 8
Number Of Gd Packets, Transmitter, Max. 8
Number Of Gd Packets, Receiver, Max. 8
Size Of Gd Packets, Max. 22 Byte
Size Of Gd Packet (Of Which Consistent), Max. 22 Byte
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 76 Byte; 76 Bytes (With X_Send Or X_Rcv); 64 Bytes (With X_Put Or X_Get
As Server)
S7 Communication
Supported Yes
As Server Yes
As Client Yes; Via Integrated Profinet Interface And Loadable Fb Or Via Cp And
Loadable Fb
User Data Per Job, Max. See Online Help Of Step 7 (Shared Parameters Of The Sfbs/Fbs And Of The
Sfcs/Fcs Of S7 Communication)
S5 Compatible Communication
Supported Yes; Via Cp And Loadable Fc
Communication Functions / Profinet Cba (With Set Target Load) / Header
Setpoint For The Cpu Communication Load 50 %
Number Of Remote Interconnection Partners 32
Number Of Master/Device Functions 30
Total Of All Master/Device Connections 1 000
Data Length Of All Incoming Master/Device Connections,
Max.4 000 Byte
Data Length Of All Outgoing Master/Device Connections,
Max.4 000 Byte
Number Of Device-Internal And Profibus
Interconnections500
Data Length Of Device-Internal Und Profibus
Interconnections, Max.4 000 Byte
Data Length Per Connection, Max. 1 400 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Acyclic Transfer / Header
— Sampling Interval, Min. 500 Ms
— Number Of Incoming Interconnections 100
— Number Of Outgoing Interconnections 100
— Data Length Of All Incoming Interconnections, Max. 2 000 Byte
— Data Length Of All Outgoing Interconnections, Max. 2 000 Byte
— Data Volume / As User Data For Remote
Interconnections / In The Case Of Acyclic Transmission /
With Profinet Cba / Per Connection / Maximum1 400 Byte
Performance Data / Profinet Cba / Remote Interconnection / With Cyclic Transfer / Header
— Transmission Frequency: Transmission Interval, Min. 10 Ms
— Number Of Incoming Interconnections 200
— Number Of Outgoing Interconnections 200
— Data Length Of All Incoming Interconnections, Max. 2 000 Byte
— Data Length Of All Outgoing Interconnections, Max. 2 000 Byte
— Data Volume / As User Data For Remote
Interconnections / With Cyclical Transfer / With
Profinet Cba / Per Connection / Maximum450 Byte
Performance Data / Profinet Cba / Hmi Variables Via Profinet / Acyclic / Header
— Number Of Stations That Can Log On For Hmi Variables
(Pn Opc/Imap)3; 2X Pn Opc/1X Imap
— Hmi Variable Updating 500 Ms
— Number Of Hmi Variables 200
— Data Length Of All Hmi Variables, Max. 2 000 Byte
Performance Data / Profinet Cba / Profibus Proxy Functionality / Header
— Supported Yes
— Number Of Linked Profibus Devices 16
— Data Length Per Connection, Max. 240 Byte; Slave-Dependent
Number Of Connections
Overall 32
Usable For Pg Communication 31
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Min. 1
— Adjustable For Pg Communication, Max. 31
Usable For Op Communication 31
— Reserved For Op Communication 1
— Adjustable For Op Communication, Min. 1
— Adjustable For Op Communication, Max. 31
Usable For S7 Basic Communication 30
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Min. 0
— Adjustable For S7 Basic Communication, Max. 30
Usable For S7 Communication 16
— Reserved For S7 Communication 0
— Adjustable For S7 Communication, Min. 0
— Adjustable For S7 Communication, Max. 16
Total Number Of Instances, Max. 32
Usable For Routing X1 As Mpi: Max. 10; X1 As Dp Master: Max. 24; X1 As Dp Slave (Active): Max.
14; X2 As Profinet: 24 Max.
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 32; Depending On The Configured Connections For Pg/Op And S7 Basic

Communication

Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 300
Test Commissioning Functions
Status Block Yes; Up To 2 Simultaneously
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max. 30
— Of Which Status Variables, Max. 30
— Of Which Control Variables, Max. 14
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 10
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 500
— Adjustable No
— Of Which Powerfail-Proof 100; Only The Last 100 Entries Are Retained
Number Of Entries Readable In Run, Max. 499
— Adjustable Yes; From 10 To 499
Preset 10
Service Data
Can Be Read Out Yes

Ambient Temperature During Operation

Min. 0 °C
Max. 60 °C
Configuration / Header
Configuration Software
Step 7 Yes; V5.5 Or Higher
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy

Dimensions

Width 40 Mm
Height 125 Mm
Depth 130 Mm
Weight S
Weight , Approx. 340 G