6ES7331-1KF02-0AB0 Siemens - MODULE INPUT S7300 8AI 13BIT 40PIN

Extended Description for 6ES7331-1KF02-0AB0 Siemens

6ES7331-1KF02-0AB0 Siemens - SIMATIC S7-300, ANALOG INPUT SM 331, OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7331-1KF02-0AB0
Product Description SIMATIC S7-300, Analog input SM 331, Isolated 8 AI, resolution 13 bits U/I/resistor/Pt100, NI100, NI1000, LG-NI1000, PTC/KTY, 66 ms conversion time; 1x 40-pole
Product family SM 331 analog input modules
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,296 Kg
Packaging Dimension 12,80 x 15,10 x 5,20
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515078425
UPC 662643523676
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 2288
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 04.01.2010
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Perfluorobutane sulfonic ... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Perfluorobutane sulfonic acid (PFBS) and its salts Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Analog Inputs

Number Of Analog Inputs 8
For Resistance Measurement 8
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.30 V; 12 V Continuous, 30 V For Max. 1 S
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Input Ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance Thermometer Yes
Resistance Yes
Input Ranges (Rated Values), Voltages
0 To +10 V Yes
— Input Resistance (0 To 10 V) 100 K Ω
1 V To 5 V Yes
— Input Resistance (1 V To 5 V) 100 K Ω
1 V To 10 V No
-1 V To +1 V Yes
— Input Resistance (-1 V To +1 V) 100 K Ω
-10 V To +10 V Yes
— Input Resistance (-10 V To +10 V) 100 K Ω
-2.5 V To +2.5 V No
-250 Mv To +250 Mv No
-5 V To +5 V Yes
— Input Resistance (-5 V To +5 V) 100 K Ω
-50 Mv To +50 Mv Yes
— Input Resistance (-50 Mv To +50 Mv) 100 K Ω
-500 Mv To +500 Mv Yes
— Input Resistance (-500 Mv To +500 Mv) 100 K Ω
-80 Mv To +80 Mv No
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 100 Ω
-10 Ma To +10 Ma No
-20 Ma To +20 Ma Yes
— Input Resistance (-20 Ma To +20 Ma) 100 Ω
-3.2 Ma To +3.2 Ma No
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 100 Ω
Input Ranges (Rated Values), Thermocouples
Type B No
Type C No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type U No
Type Txk/Txk(L) To Gost No
Input Ranges (Rated Values), Resistance Thermometer
Cu 10 No
Ni 100 Yes; Standard/Climate
— Input Resistance (Ni 100) 100 M Ω
Ni 1000 Yes
— Input Resistance (Ni 1000) 100 M Ω
Lg-Ni 1000 Yes; Standard/Climate
— Input Resistance (Lg-Ni 1000) 100 M Ω
Ni 120 No
Ni 200 No
Ni 500 No
Pt 100 Yes; Standard/Climate
— Input Resistance (Pt 100) 100 M Ω
Pt 1000 No
Pt 200 No
Pt 500 No
Input Ranges (Rated Values), Resistors
0 To 150 Ohms No
0 To 300 Ohms No
0 To 600 Ohms Yes
— Input Resistance (0 To 600 Ohms) 100 M Ω
0 To 6000 Ohms Yes
— Input Resistance (0 To 6000 Ohms) 100 M Ω
Thermocouple (Tc)
Temperature Compensation
— Parameterizable No
— Internal Temperature Compensation No
— External Temperature Compensation With
Compensations Socketno
Characteristic Linearization
Parameterizable Yes
— For Thermocouples No
— For Resistance Thermometer Yes; Pt100 Standard/Air Con.; Ni100 Standard/Air Con.; Ni1000 Standard/Air Con.;
Lg-Ni1000 Standard/Air Con.
Cable Length
Shielded, Max. 200 M; Max. 50 M At 50 Mv
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 13 Bit
Integration Time, Parameterizable Yes; 60 / 50 Ms
Basic Conversion Time (Ms) 66 / 55 Ms
Interference Voltage Suppression For Interference
Frequency F1 In Hz50 / 60 Hz
Encoder
Connection Of Signal Encoders
For Voltage Measurement Yes
For Current Measurement As 2-Wire Transducer Yes; With External Supply
For Current Measurement As 4-Wire Transducer Yes
For Resistance Measurement With Two-Wire Connection Yes
For Resistance Measurement With Three-Wire Connection Yes
For Resistance Measurement With Four-Wire Connection Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Input Range, (+/-) 0.6 %; ±0.6 % (±5 V, 10 V, 1 To 5 V, 0 To 10 V); ±0.5 % (±50 Mv, 500 Mv, 1 V)
Current, Relative To Input Range, (+/-) 0.5 %; ±20 Ma, 0 To 20 Ma, 4 To 20 Ma
Resistance, Relative To Input Range, (+/-) 0.5 %; 0 To 6 Kohms, 0 To 600 Kohms
Resistance Thermometer, Relative To Input Range, (+/-) 1 Kelvin (Pt100, Ni100, Climatic; Ni1000, Lg-Ni1000, Standard; Ni1000, Lg-
Ni1000, Climatic); 1.2 Kelvin (Pt100, Ni100, Standard)
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Input Range, (+/-) 0.4 %; 0.4% (±5 V, 10 V, 1 To 5 V, 0 To 10 V); 0.3% (±50 Mv, 500 Mv, 1 V)
Current, Relative To Input Range, (+/-) 0.3 %; ±20 Ma, 0 To 20 Ma, 4 To 20 Ma
Resistance, Relative To Input Range, (+/-) 0.3 %; 0 To 6 Kohms, 0 To 600 Kohms
Resistance Thermometer, Relative To Input Range, (+/-) 1 Kelvin (Pt100, Ni100, Standard); 0.8 Kelvin (Pt100, Ni100, Climatic; Ni1000,
Lg-Ni1000, Standard; Ni1000, Lg-Ni1000, Climatic)
Interrupts/Diagnostics/Status Information
Diagnostics Function No
Alarms
Diagnostic Alarm No
Limit Value Alarm No
Diagnoses
Diagnostic Information Readable No
Diagnostics Indication Led
Group Error Sf (Red) No
Potential Separation
Potential Separation Analog Inputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Isolation
Isolation Tested With 500 V Dc
Connection Method
Required Front Connector 40-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 117 Mm