This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7331-7TB00-0AB0

6ES7331-7TB00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7331-7TB00-0AB0 Siemens

6ES7331-7TB00-0AB0 Siemens - ********** Replacement part ********* SIMATIC DP, HART analog input SM 331, 2 AI, 0/4 - 20 mA HART, to HART rev. 5.0, for ET200M with IM 153-2, 1 x 20-pole

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7331-7TB00-0AB0
Product Description ******* repair part ******* SIMATIC DP, HART analog input SM 331, 2 AI, 0/4 - 20 mA HART to HART rev. 5.0, for ET200M with IM 153-2, 1 x 20-pole
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2016
Notes Sucessor:Successor: 6ES7331-7TB10-0AB0 This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) On request
Net Weight (kg) 0,366 Kg
Packaging Dimension 13,20 x 15,20 x 5,10
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515061243
UPC Not available
Commodity Code 85389091
LKZ_FDB/ CatalogID STPCS7
Product Group 4519
Group Code R1TP
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 21.10.2016
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Load Voltage L+ (Without Load), Max. 180 Ma
From Backplane Bus 5 V Dc, Max. 100 Ma
Output Voltage / Header
Supply Voltage Of The Transmitters / Header
Present Yes
Rated Value (Dc) 15 V; At 22 Ma
Short-Circuit Proof Yes; Approx. 30 Ma
No-Load Voltage (Dc) 29.6 V
Power Loss
Power Loss , Typ. 4.5 W

Analog Inputs

Number Of Analog Inputs 2
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 50 Ω
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 50 Ω
Cable Length
Shielded, Max. 400 M
Analog Value Generation For The Inputs
Measurement Principle Sigma Delta
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit; 10 Bit To 15 Bit + Sign
Integration Time, Parameterizable Yes
Integration Time (Ms) 2,5 / 16,67 / 20 / 100 Ms
Basic Conversion Time, Including Integration Time (Ms) 2.5 / 16.67 / 20 / 100 (1 Channel Enabled); 7.5 / 50 / 60 / 300 (2 Channels
Enabled)
Interference Voltage Suppression For Interference
Frequency F1 In Hz10 / 50 / 60 / 400 Hz
Encoder
Connection Of Signal Encoders
For Current Measurement As 2-Wire Transducer Yes
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Current, Relative To Input Range, (+/-) 0.45 %; From 0/4 To 20 Ma
Basic Error Limit (Operational Limit At 25 °C)
Current, Relative To Input Range, (+/-) 0.1 %; From 0/4 To 20 Ma
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Can Be Set In Parameters, Red Led, Alarm Message
Alarms
Diagnostic Alarm Yes; Parameterizable
Limit Value Alarm Yes; Parameterizable, Channels 0 And 1
Diagnoses
Overrange Yes; Red Led, Signal
Wire-Break In Signal Transmitter Cable Yes; Red Led, Signal
Short-Circuit Of The Signal Encoder Cable Yes; Red Led, Signal
Hart Communication Active Yes; Green Led (H)
Diagnostics Indication Led
Group Error Sf (Red) Yes
Channel Fault Indicator F (Red) Yes
Ex(I) Characteristics
Module For Ex(I) Protection Yes
Maximum Values For Connecting Terminals For Gas Group Iic
Uo (No-Load Voltage), Max. 26 V
Io (Short-Circuit Current), Max. 96.1 Ma
Po (Power Output), Max. 511 Mw
Co (Permissible External Capacity), Max. 62 Nf
Lo (Permissible External Inductivity), Max. 3 Mh
Um (Voltage At Non-Intrinsically Safe Connecting
Terminals), Max.250 V; Dc
Potential Separation
Potential Separation Analog Inputs
Between The Channels Yes
Between The Channels And Backplane Bus Yes
Permissible Potential Difference
Between The Inputs (Ucm) 60 V Dc/30 V Ac
Standards, Approvals, Certificates
Fm Approval In Preparation
Use In Hazardous Areas
Atex Marking Ii3 (2) G Eex Na [Ib] Iic T4
Atex Certificate Kema 97 Atex 3039X
Fm Marking Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, Group Iic T4

Ambient Temperature During Operation

Min. 0 °C
Max. 60 °C

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 260 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible