Description for 6ES7332-5TB00-0AB0 Siemens

6ES7332-5TB00-0AB0 Siemens - ********** Replacement part ********* SIMATIC DP, HART analog output, SM 332, 2 AO, 0/4 - 20 mA HART, to HART rev. 5.0, for ET200M with IM 153-2, 1 x 20-pole

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7332-5TB00-0AB0
Product Description ********** Replacement part ********* SIMATIC DP, HART analog output, SM 332, 2 AO, 0/4 - 20 mA HART, to HART rev. 5.0, for ET200M with IM 153-2, 1 x 20-pole
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 01.10.2016
Notes Sucessor:Successor: 6ES7332-5TB10-0AB0 This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,336 Kg
Packaging Dimension 13,10 x 15,20 x 5,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515061311
UPC Not available
Commodity Code 85389091
LKZ_FDB/ CatalogID STPCS7
Product Group 4A41
Group Code R1TP
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Product is not RoHS-compliant
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Load Voltage L+ (Without Load), Max. 150 Ma
From Backplane Bus 5 V Dc, Max. 100 Ma
Power Loss
Power Loss , Typ. 3.5 W
Analog Outputs
Number Of Analog Outputs 2
Voltage Output, Short-Circuit Protection Yes
Current Output, No-Load Voltage, Max. 19 V
Cycle Time (All Channels) Max. 5 Ms
Output Ranges, Current
0 To 20 Ma Yes
4 Ma To 20 Ma Yes
Connection Of Actuators
For Current Output Two-Wire Connection Yes
Load Impedance (In Rated Range Of Output)
With Current Outputs, Max. 650 Ω
With Current Outputs, Inductive Load, Max. 7.5 Mh
Destruction Limits Against Externally Applied Voltages And Currents
Voltages At The Outputs Towards Mana Max. 17 V / -0.5 V
Current, Max. 60 Ma / -1 A
Cable Length
Shielded, Max. 400 M
Analog Value Generation For The Outputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 12 Bit; Output Value; 8 Bit (+ Sign) Read Back Value
Conversion Time (Per Channel) 40 Ms
Settling Time
For Resistive Load 2.5 Ms
For Capacitive Load 4 Ms
For Inductive Load 2.5 Ms
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Current, Relative To Output Range, (+/-) 0.55 %
Basic Error Limit (Operational Limit At 25 °C)
Current, Relative To Output Range, (+/-) 0.15 %
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Substitute Values Connectable Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Diagnoses
Overrange Yes
Wire-Break Yes; As Of Output Value > 0.5 Ma
Wire-Break In Actuator Cable Yes
Hart Communication Active Yes; Green Led (H)
Diagnostics Indication Led
Group Error Sf (Red) Yes; Additional Group Message Per Channel
Channel Fault Indicator F (Red) Yes; Per Channel
Ex(I) Characteristics
Module For Ex(I) Protection Yes
Maximum Values For Connecting Terminals For Gas Group Iic
Uo (No-Load Voltage), Max. 19 V
Io (Short-Circuit Current), Max. 66 Ma
Po (Power Output), Max. 506 Mw
Co (Permissible External Capacity), Max. 230 Nf
Lo (Permissible External Inductivity), Max. 7.5 Mh
Um (Voltage At Non-Intrinsically Safe Connecting
Terminals), Max.60 V; Dc
Potential Separation
Potential Separation Analog Outputs
Between The Channels Yes
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ Yes
Permissible Potential Difference
Between The Outputs (Ucm) 60 V Dc/30 V Ac
Between M Internally And The Outputs 60 V Dc/30 V Ac
Standards, Approvals, Certificates
Fm Approval In Preparation
Use In Hazardous Areas
Atex Marking Ii3 (2) G Eex Na [Ib] Iic T4
Atex Certificate 97 Atex 2359 X
Fm Marking Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, Group Iic T4

Ambient Temperature During Operation

Max. 60 °C

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S
Weight , Approx. 280 G