This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7334-0KE00-0AB0

6ES7334-0KE00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7334-0KE00-0AB0 Siemens

6ES7334-0KE00-0AB0 Siemens - MODULE IN/OUT S7300 4AI 2AO 12BT 20PIN

Extended Description for 6ES7334-0KE00-0AB0 Siemens

6ES7334-0KE00-0AB0 Siemens - SIMATIC S7-300, ANALOG MODULE SM 334, OPTICALLY ISOLATED, 4AE/2AA, 12 BIT, 0-10V F. PT100 (CLIMAT RANGE -120 - 155 DEGR.) AND 10 KOHM MEASURING RANGE, 1 X 20 PIN

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7334-0KE00-0AB0
Product Description SIMATIC S7-300, Analog module SM 334, isolated, 4 AI/2 AO, 12 bit, 0-10 V f. Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole
Product family SM 334 analog input/output modules
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,241 Kg
Packaging Dimension 12,80 x 15,20 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515061359
UPC 662643118278
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 2288
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 06.03.2007
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Perfluorobutane sulfonic ... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Perfluorobutane sulfonic acid (PFBS) and its salts Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Supply And Load Voltage L+ (Without Load), Max. 80 Ma
From Backplane Bus 5 V Dc, Max. 60 Ma
Power Loss
Power Loss , Typ. 2 W

Analog Inputs

Number Of Analog Inputs 4
For Voltage Measurement 2
For Resistance Measurement 4
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.20 V; Continuous; 75 V For Max. 1 S (Mark To Space Ratio 1:20)
Constant Measurement Current For Resistance-Type Transmitter,
Typ.490 Μa; At Pt100 (490 Μa), At 10 Kohm (105 Μa)
Cycle Time (All Channels) Max. 85 Ms
Input Ranges
Voltage Yes
Current No
Thermocouple No
Resistance Thermometer Yes
Resistance Yes
Input Ranges (Rated Values), Voltages
0 To +10 V Yes
— Input Resistance (0 To 10 V) 100 K Ω
Input Ranges (Rated Values), Resistance Thermometer
Pt 100 Yes; Only Climatic Range
Input Ranges (Rated Values), Resistors
0 To 10000 Ohms Yes
Characteristic Linearization
Parameterizable Yes
— For Resistance Thermometer Pt100 (Climate)
Cable Length
Shielded, Max. 100 M
Analog Outputs
Number Of Analog Outputs 2
Voltage Output, Short-Circuit Protection Yes
Voltage Output, Short-Circuit Current, Max. 30 Ma
Output Ranges, Voltage
0 To 10 V Yes
Load Impedance (In Rated Range Of Output)
With Voltage Outputs, Min. 2.5 K Ω
With Voltage Outputs, Capacitive Load, Max. 1 Μf
Cable Length
Shielded, Max. 100 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 12 Bit
Integration Time, Parameterizable Yes
Integration Time (Ms) 16,67 / 20 Ms
Interference Voltage Suppression For Interference
Frequency F1 In Hz50 / 60 Hz
Analog Value Generation For The Outputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 12 Bit
Conversion Time (Per Channel) 500 Μs
Settling Time
For Resistive Load 0.8 Ms
For Capacitive Load 0.8 Ms
Encoder
Connection Of Signal Encoders
For Voltage Measurement Yes
For Resistance Measurement With Two-Wire Connection Yes
For Resistance Measurement With Three-Wire Connection Yes
For Resistance Measurement With Four-Wire Connection Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Input Range, (+/-) 0.7 %; 0 To 10V
Resistance, Relative To Input Range, (+/-) 3.5 %; 10 Kohm
Resistance Thermometer, Relative To Input Range, (+/-) 1 %
Voltage, Relative To Output Range, (+/-) 1 %
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Input Range, (+/-) 0.5 %; 0 To 10V
Resistance, Relative To Input Range, (+/-) 2.8 %; 10 Kohm
Resistance Thermometer, Relative To Input Range, (+/-) 0.8 %
Voltage, Relative To Output Range, (+/-) 0.85 %
Interrupts/Diagnostics/Status Information
Alarms No
Diagnostics Function No
Potential Separation
Potential Separation Analog Inputs
Between The Channels And Backplane Bus Yes
Potential Separation Analog Outputs
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Isolation Tested With 500 V Dc
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 117 Mm
Weight S
Weight , Approx. 200 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible