Description for 6ES7336-4GE00-0AB0 Siemens

6ES7336-4GE00-0AB0 Siemens - SIMATIC S7, ANALOG INPUT SM 336

Extended Description for 6ES7336-4GE00-0AB0 Siemens

6ES7336-4GE00-0AB0 Siemens - SIMATIC S7, ANALOG INPUT SM336, 6 AI; 15 BIT; 20 PIN, FAILSAFE ANALOG INPUTS SIL 3, FOR SIMATIC SAFETY, WITH HART SUPPORT

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7336-4GE00-0AB0
Product Description SIMATIC S7, Analog input SM 336, 6 AI; 15 bit; fail-safe analog inputs for SIMATIC Safety, with HART support, up to Category 4 (EN 954-1)/ SIL3 (IEC61508)/PLE (ISO13849), 1x 20-pole
Product family SM 336 F-analog input modules - Safety Integrated
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,339 Kg
Packaging Dimension 13,10 x 15,10 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515076025
UPC 662643401479
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 2298
Group Code R152
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 10.10.2008
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Perfluorobutane sulfonic ... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Perfluorobutane sulfonic acid (PFBS) and its salts Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Load Voltage L+
Rated Value (Dc) 24 V
Reverse Polarity Protection Yes
Input Current
From Power Supply L+, Typ. 150 Ma
From Backplane Bus 5 V Dc, Max. 90 Ma
Power Loss
Power Loss , Typ. 4.5 W

Analog Inputs

Number Of Analog Inputs 6
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Input Ranges
Voltage No
Current Yes
Thermocouple No
Resistance Thermometer No
Resistance No
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 150 Ω; Typ. 150 Ohms Max. 175 Ohms
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 150 Ω; Typ. 150 Ohms Max. 175 Ohms
Cable Length
Shielded, Max. 1 000 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit; 15 Bit + Sign
Integration Time (Ms) 20 Ms @ 50 Hz, 16.7 Ms @ 60 Hz
Interference Voltage Suppression For Interference
Frequency F1 In Hzf=N X (F1 ±0.5 %)
Encoder
Connection Of Signal Encoders
For Current Measurement As 2-Wire Transducer Yes
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Current, Relative To Input Range, (+/-) 0.2 %; 40 Μa
Basic Error Limit (Operational Limit At 25 °C)
Current, Relative To Input Range, (+/-) 0.1 %
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Diagnostic Information Readable Yes
Diagnostics Indication Led
Fail-Safe Operation Yes
Group Error Sf (Red) Yes
Encoder Supply Vs (Green) No
Potential Separation
Potential Separation Analog Inputs
Between The Channels Yes
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Isolation
Isolation Tested With 370V For 1 Min
Standards, Approvals, Certificates
Highest Safety Class Achievable In Safety Mode
Acc. To En 954 4
Performance Level According To Iso 13849-1 E
Sil Acc. To Iec 61508 Sil 3
Connection Method
Required Front Connector 20-Pin

Dimensions

Width 40 Mm
Height 125 Mm
Depth 120 Mm
Weight S