6ES7412-5HK06-0AB0 Siemens - SIMATIC S7-400H, CPU 412-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 1 MB memory (512 KB data/512 KB program)

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7412-5HK06-0AB0
Product Description SIMATIC S7-400H, CPU 412-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 1 MB memory (512 KB data/512 KB program)
Product family CPU 412H
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 1,332 Kg
Packaging Dimension 23,30 x 30,00 x 6,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4019169234702
UPC 040892941180
Commodity Code 85371091
LKZ_FDB/ CatalogID ST74
Product Group 4040
Group Code R338
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 05.04.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode No
Engineering With
Programming Package As Of Step 7 V5.5 Sp2 With Hf1
Cir - Configuration In Run
Cir Synchronization Time, Basic Load 100 Ms
Cir Synchronization Time, Time Per I/O Byte 0 Μs

Supply Voltage

Rated Value (Dc) Power Supply Via System Power Supply
Input Current
From Backplane Bus 5 V Dc, Typ. 1.6 A
From Backplane Bus 5 V Dc, Max. 1.9 A
From Backplane Bus 24 V Dc, Max. 150 Ma; 150 Ma Per Dp Interface
From Interface 5 V Dc, Max. 90 Ma; At Each Dp Interface
Power Loss
Power Loss , Typ. 7.5 W
Memory
Type Of Memory Ram
Work Memory
Integrated 1 Mbyte
Integrated (For Program) 512 Kbyte
Integrated (For Data) 512 Kbyte
Expandable No
Load Memory
Expandable Feprom Yes; With Memory Card (Flash)
Expandable Feprom, Max. 64 Mbyte
Integrated Ram, Max. 512 Kbyte
Expandable Ram Yes
Expandable Ram, Max. 64 Mbyte
Backup
Present Yes
With Battery Yes; All Data
Without Battery No
Battery
Backup Battery
Backup Current, Typ. 180 Μa; Valid Up To 40°C
Backup Current, Max. 1 000 Μa
Backup Time, Max. Dealt With In The Module Data Manual With The Secondary Conditions And The
Factors Of Influence
Feeding Of External Backup Voltage To Cpu 5 V Dc To 15 V Dc
Cpu Processing Times
For Bit Operations, Typ. 31.25 Ns
For Word Operations, Typ. 31.25 Ns
For Fixed Point Arithmetic, Typ. 31.25 Ns
For Floating Point Arithmetic, Typ. 62.5 Ns
Cpu-Blocks
Db
Number, Max. 6 000; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 3 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 3 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 4; Ob 10-13
Number Of Delay Alarm Obs 4; Ob 20-23
Number Of Cyclic Interrupt Obs 4; Ob 32-35
Number Of Process Alarm Obs 4; Ob 40-43
Number Of Dpv1 Alarm Obs 3; Ob 55-57
Number Of Startup Obs 2; Ob 100, 102
Number Of Asynchronous Error Obs 9; Ob 80-88
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 24
Additional Within An Error Ob 1
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
— Preset No Times Retentive
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. Total Working And Load Memory (With Backup Battery)
Flag
Size, Max. 8 192 Byte
Retentivity Available Yes
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; In 1 Memory Byte
Local Data
Adjustable, Max. 16 Kbyte
Preset 8 Kbyte
Address Area
I/O Address Area
Inputs 8 Kbyte
Outputs 8 Kbyte
Process Image
Inputs, Adjustable 8 Kbyte
Outputs, Adjustable 8 Kbyte
Inputs, Default 256 Byte
Outputs, Default 256 Byte
Consistent Data, Max. 244 Byte
Access To Consistent Data In Process Image Yes
Subprocess Images
Number Of Subprocess Images, Max. 15
Digital Channels
Inputs 65 536
— Of Which Central 65 536
Outputs 65 536
— Of Which Central 65 536
Analog Channels
Inputs 4 096
— Of Which Central 4 096
Outputs 4 096
— Of Which Central 4 096
Hardware Configuration
Number Of Expansion Units, Max. 21
Connectable Ops 47
Multicomputing No
Interface Modules
Number Of Connectable Ims (Total), Max. 6
Number Of Connectable Im 460S, Max. 6
Number Of Connectable Im 463S, Max. 4; Single Mode Only
Number Of Dp Masters
Integrated 2
Via Cp 10; Cp 443-5 Extended
Mixed Mode Im + Cp Permitted No
Via Interface Module 0
Number Of Io Controllers
Integrated 1
Via Cp 0
Number Of Operable Fms And Cps (Recommended)
Fm See Manual Automation System S7-400H Fault-Tolerant Systems. Limited By
Number Of Slots And Number Of Connections
Cp, Ptp See Manual Automation System S7-400H Fault-Tolerant Systems. Limited By
Number Of Slots And Number Of Connections
Profibus And Ethernet Cps 14; Of Which Max. 10 Cp As Dp Master
Slots
Required Slots 2
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Resolution 1 Ms
Deviation Per Day (Buffered), Max. 1.7 S; Power Off
Deviation Per Day (Unbuffered), Max. 8.6 S; Power On
Operating Hours Counter
Number 16
Number/Number Range 0 To 15
Range Of Values Sfcs 2, 3 And 4: 0 To 32767 Hours Sfc 101: 0 To 2^31 - 1 Hours
Granularity 1 H
Retentive Yes
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp Yes; As Client
Time Difference In System When Synchronizing Via
Ethernet, Max. 10 Ms; Via Ntp
Mpi, Max. 200 Ms
Interfaces
Number Of Rs 485 Interfaces 2
Number Of Other Interfaces 2; Fiber-Optic Interface
Optical Interface No
1. Interface
Interface Type Mpi/Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device No
Mpi
Number Of Connections 32; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
Profibus Dp Master
Number Of Connections, Max. 16; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance No
— Isochronous Mode No
— Sync/Freeze No
— Activation/Deactivation Of Dp Devices No
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv1 Yes
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
1St Interface / Profibus Dp Device / Header
Number Of Connections No Configuration Of Cpu As Dp Slave
2. Interface
Interface Type Profinet
Isolated Yes
Automatic Detection Of Transmission Rate Yes; Autosensing
Autonegotiation Yes
Autocrossing Yes
Change Of Ip Address At Runtime, Supported No
Interface Types
Rj 45 (Ethernet) Yes
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Controller Yes
Profinet Io Device No
Profinet Cba No
Profibus Dp Master No
Profibus Dp Device No
Open Ie Communication Yes
Web Server No
Point-To-Point Connection No
Media Redundancy Yes
Profinet Io Controller
Transmission Rate, Max. 100 Mbit/S
Services
— Pg/Op Communication Yes
— S7 Communication Yes
— Isochronous Mode No
— Shared Device Yes; Single Mode Only
— Prioritized Startup No
— Number Of Connectable Io Devices, Max. 256; In Redundant Mode Via Both Interfaces
— Number Of Connectable Io Devices For Rt, Max. 256
— Of Which In Line, Max. 256
— Activation/Deactivation Of Io Devices No
— Io Devices Changing During Operation (Partner
Ports), Supportedno
— Device Replacement Without Swap Medium Yes
— Send Cycles 250 Μs, 500 Μs, 1 Ms, 2 Ms, 4 Ms
— Updating Time 250 Μs To 512 Ms, Minimum Value Depends On The Number Of Configured User
Data And The Configured Single Or Redundant Mode
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
— User Data Consistency, Max. 1 024 Byte
Open Ie Communication
Number Of Connections, Max. 46
Local Port Numbers Used At The System End 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534,
65535
Keep-Alive Function, Supported Yes
3. Interface
Interface Type Profibus Dp
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Profibus Dp Master Yes
Profibus Dp Device No
Profibus Dp Master
Number Of Connections, Max. 16
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 64
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance No
— Isochronous Mode No
— Sync/Freeze No
— Activation/Deactivation Of Dp Devices No
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv0 Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 4 Kbyte
— Outputs, Max. 4 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
4. Interface
Interface Type Pluggable Synchronization Submodule (Fo)
Plug-In Interface Modules Synchronization Modules 6Es7960-1Aa06-0Xa0 Or 6Es7960-1Ab06-0Xa0
5. Interface
Interface Type Pluggable Synchronization Submodule (Fo)
Plug-In Interface Modules Synchronization Modules 6Es7960-1Aa06-0Xa0 Or 6Es7960-1Ab06-0Xa0
Protocols
Redundancy Mode
Media Redundancy
— Switchover Time On Line Break, Typ. 200 Ms
— Number Of Stations In The Ring, Max. 50
Simatic Communication
S7 Routing Yes
Open Ie Communication
Tcp/Ip Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 46
— Data Length, Max. 32 Kbyte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes; Via Integrated Profinet Interface Or Cp 443-1 And Loadable Fbs
— Number Of Connections, Max. 46
— Data Length, Max. 32 Kbyte; 1 452 Bytes Via Cp 443-1 Adv.
Udp Yes; Via Integrated Profinet Interface And Loadable Fbs
— Number Of Connections, Max. 46
— Data Length, Max. 1 472 Byte
Web Server
Supported No
Isochronous Mode
Equidistance No
Communication Functions / Header
Pg/Op Communication Yes
Number Of Connectable Ops Without Message Processing 47
Number Of Connectable Ops With Message Processing 47; When Using Alarm_S/Sq And Alarm_D/Dq
Data Record Routing Yes
Global Data Communication
Supported No
S7 Basic Communication
Supported No
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. 64 Kbyte
User Data Per Job (Of Which Consistent), Max. 462 Byte; 1 Variable
S5 Compatible Communication
Supported Yes; (Via Cp Max. 10 And Fc Ag_Send And Fc Ag_Recv)
User Data Per Job, Max. 8 Kbyte
User Data Per Job (Of Which Consistent), Max. 240 Byte
Number Of Simultaneous Ag-Send/Ag-Recv Orders Per
Cpu, Max.64/64
Standard Communication (Fms)
Supported Yes; Via Cp And Loadable Fb
Number Of Connections
Overall 48
Usable For Pg Communication
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Max. 0
Usable For Op Communication
— Reserved For Op Communication 1
— Adjustable For Op Communication, Max. 0
Usable For S7 Basic Communication
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Max. 0
Usable For S7 Communication
— Reserved For S7 Communication 0
— Adjustable For S7 Communication, Max. 0
Usable For Routing
— Reserved For Routing 0
— Adjustable For Routing, Max. 0
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 47; Max. 47 With Alarm_S/Sq And Alarm_D/Dq (Ops); Max. 8 With Alarm,
Alarm_8, Alarm_8P, Notify And Notify_8 (E.G. Wincc)
Symbol-Related Messages No
Scan Procedure No
Program Alarms Yes
Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 250; Simultaneously Active Alarm_S/Sq Blocks Or Alarm_D/Dq Blocks
Alarm 8-Blocks Yes
Number Of Instances For Alarm 8 And S7 Communication
Blocks, Max.600
Preset, Max. 300
Process Control Messages Yes
Number Of Archives That Can Log On Simultaneously (Sfb 37
Ar_Send)16
Test Commissioning Functions
Status Block Yes
Single Step Yes
Number Of Breakpoints 16
Status/Control
Status/Control Variable Yes; Up To 16 Variable Tables
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max. 70
Forcing
Forcing Yes
Forcing, Variables Inputs/Outputs, Bit Memories, Distributed I/Os
Number Of Variables, Max. 256
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Adjustable Yes
Preset 120
Service Data
Can Be Read Out Yes
Emc
Emission Of Radio Interference Acc. To En 55 011
Limit Class A, For Use In Industrial Areas Yes
Limit Class B, For Use In Residential Areas No
Configuration / Header
Configuration Software
Step 7 Yes
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 7
Access To Consistent Data In Process Image Yes
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Configuration / Programming / Number Of Simultaneously Active Sfc / Header
Rd_Rec 8
Wr_Rec 8
Wr_Parm 8
Parm_Mod 1
Wr_Dparm 2
Dpnrm_Dg 8
Rdsysst 8
Dp_Topol 1
Configuration / Programming / Number Of Simultaneously Active Sfb / Header
Rdrec 8
Wrrec 8
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy

Dimensions

Width 50 Mm
Height 290 Mm
Depth 219 Mm
Weight S
Weight , Approx. 995 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible