This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7416-2XK04-0AB0

6ES7416-2XK04-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7416-2XK04-0AB0 Siemens

6ES7416-2XK04-0AB0 Siemens - ********** Replacement part ********* SIMATIC S7-400, CPU 416-2 Central processing unit with: work memory 2.8 MB, (1.4 MB code, 1.4 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7416-2XK04-0AB0
Product Description ********** Replacement part ********* SIMATIC S7-400, CPU 416-2 Central processing unit with: work memory 2.8 MB, (1.4 MB code, 1.4 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 19.02.2007
Notes The product was replaced with the following successor product: 6ES7416-2XP07-0AB0 Compare Products This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Successor information

Successor 6ES7416-2XP07-0AB0
Successor Description SIMATIC S7-400, CPU 416-2, Central processing unit with: Work memory 8 MB, (4 MB code, 4 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP,

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,870 Kg
Packaging Dimension 23,30 x 30,20 x 4,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4019169123563
UPC Not available
Commodity Code 85389091
LKZ_FDB/ CatalogID ST9-E5
Product Group 4A41
Group Code R1TP
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Product is not RoHS-compliant
Product class D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes
Engineering With
Programming Package Step 7 V5.2 Sp1 Hf3 Or Higher With Hw Update
Cir - Configuration In Run
Cir Synchronization Time, Basic Load 100 Ms
Cir Synchronization Time, Time Per I/O Byte 40 Μs

Supply Voltage

Rated Value (Dc) Power Supply Via System Power Supply
Input Current
From Backplane Bus 5 V Dc, Typ. 1 A
From Backplane Bus 5 V Dc, Max. 1.2 A
From Backplane Bus 24 V Dc, Max. Total Current Consumption Of The Components Connected To The Mpi/Dp
Interfaces, But No More Than 150 Ma Per Interface
Power Loss
Power Loss , Typ. 4.5 W
Memory
Type Of Memory Ram
Work Memory
Integrated (For Program) 1 400 Kbyte
Integrated (For Data) 1 400 Kbyte
Expandable No
Load Memory
Expandable Feprom Yes; With Memory Card (Flash)
Expandable Feprom, Max. 64 Mbyte
Integrated Ram, Max. 256 Kbyte
Expandable Ram Yes; With Memory Card (Ram)
Expandable Ram, Max. 16 Mbyte
Backup
Present Yes
With Battery Yes; All Data
Without Battery No
Battery
Backup Battery
Backup Current, Typ. 550 Μa
Backup Current, Max. 1 539 Μa
Backup Time, Max. 144 D
Feeding Of External Backup Voltage To Cpu 5 V Dc To 15 V Dc
Cpu Processing Times
For Bit Operations, Typ. 0.04 Μs
For Word Operations, Typ. 0.04 Μs
For Fixed Point Arithmetic, Typ. 0.04 Μs
For Floating Point Arithmetic, Typ. 0.12 Μs
Cpu-Blocks
Db
Number, Max. 4 095; Db 0 Reserved
Size, Max. 64 Kbyte
Fb
Number, Max. 2 048
Size, Max. 64 Kbyte
Fc
Number, Max. 2 048
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Time Alarm Obs 8
Number Of Delay Alarm Obs 4
Number Of Cyclic Interrupt Obs 9
Number Of Process Alarm Obs 8
Number Of Multicomputing Obs 1
Nesting Depth
Per Priority Class 24
Additional Within An Error Ob 2
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
— Preset No Times Retentive
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. Total Working And Load Memory (With Backup Battery)
Flag
Size, Max. 16 Kbyte
Retentivity Available Yes; Mb 0 To Mb 16383
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; 1 Memory Byte
Local Data
Adjustable, Max. 32 Kbyte
Preset 16 Kbyte
Address Area
I/O Address Area
Inputs 16 Kbyte
Outputs 16 Kbyte
Process Image
Inputs, Adjustable 16 Kbyte
Outputs, Adjustable 16 Kbyte
Inputs, Default 512 Byte
Outputs, Default 512 Byte
Consistent Data, Max. 244 Byte
Access To Consistent Data In Process Image Yes
Subprocess Images
Number Of Subprocess Images, Max. 15
Digital Channels
Inputs 131 072
— Of Which Central 131 072
Outputs 131 072
— Of Which Central 131 072
Analog Channels
Inputs 8 192
— Of Which Central 8 192
Outputs 8 192
— Of Which Central 8 192
Hardware Configuration
Number Of Expansion Units, Max. 21; Of Which 6 Er With K-Bus
Connectable Ops 63 Without Message Processing, 12 With Message Processing
Multicomputing Yes; 4 Cpus Max. (With Ur1 Or Ur2)
Interface Modules
Number Of Connectable Ims (Total), Max. 6
Number Of Connectable Im 460S, Max. 6
Number Of Connectable Im 463S, Max. 4; Im 463-2
Number Of Dp Masters
Integrated 2
Via Cp 10; Cp 443-5 Extended
Via Im 467 4
Mixed Mode Im + Cp Permitted No; Im 467 Cannot Be Used Jointly With Cp 443-5 Ext.
Number Of Pluggable S5 Modules (Via Adapter Capsule In
Central Device), Max.6
Number Of Operable Fms And Cps (Recommended)
Fm Limited By Number Of Slots And Number Of Connections
Cp, Ptp Cp 440: Limited By Number Of Slots; Cp 441: Limited By Number Of Connections
Cp, Lan Limited By Number Of Slots And Number Of Connections
Profibus And Ethernet Cps 14; Incl. Cp 443-5 Ext. And Im 467
Slots
Required Slots 1
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Resolution 1 Ms
Deviation Per Day (Buffered), Max. 1.7 S; Power On
Deviation Per Day (Unbuffered), Max. 8.6 S; Power Off
Operating Hours Counter
Number 8
Number/Number Range 0 To 7
Range Of Values 0 To 32767 Hours
Granularity 1 H
Retentive Yes
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
1. Interface
Interface Type Mpi/Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device Yes
Mpi
Number Of Connections 44
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
Profibus Dp Master
Number Of Connections, Max. 32; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
— Equidistance Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
1St Interface / Profibus Dp Device / Header
Gsd File Http://Www.Siemens.Com/Profibus-Gsd
Transmission Rate, Max. 12 Mbit/S
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte
— Of Which Consistent, Max. 32 Byte
Services
— Pg/Op Communication Yes
— Routing Yes
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
2. Interface
Interface Type Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Profibus Dp Master Yes
Profibus Dp Device Yes
Profibus Dp Master
Number Of Connections, Max. 32; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 125
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
— Equidistance Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
User Data Per Dp Device
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
2Nd Interface / Profibus Dp Device / Header
Transmission Rate, Max. 12 Mbit/S
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte
— Of Which Consistent, Max. 32 Byte
Services
— Routing Yes
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
Protocols
Simatic Communication
S7 Routing Yes
Isochronous Mode
Equidistance Yes
User Data Per Isochronous Slave, Max. 244 Byte
Shortest Clock Pulse 1 Ms
Max. Cycle 32 Ms
Communication Functions / Header
Pg/Op Communication Yes
Number Of Connectable Ops Without Message Processing 63
Number Of Connectable Ops With Message Processing 12
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 16
Number Of Gd Packets, Transmitter, Max. 16
Number Of Gd Packets, Receiver, Max. 32
Size Of Gd Packets, Max. 64 Byte
Size Of Gd Packet (Of Which Consistent), Max. 1 Variable
S7 Basic Communication
Supported Yes; In Mpi Mode Via: Sfc X_Send, X_Rcv, X_Get And X_Put; In Dp
Master Mode Via: Sfc I_Get And I_Put
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 1 Variable
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. 64 Kbyte
User Data Per Job (Of Which Consistent), Max. 462 Byte; 1 Variable
S5 Compatible Communication
Supported Yes; Via Fc Ag_Send And Ag_Recv, Max. Via 10 Cp 443-1 Or 443-5
User Data Per Job, Max. 8 Kbyte
User Data Per Job (Of Which Consistent), Max. 240 Byte
Standard Communication (Fms)
Supported Yes; Via Cp And Loadable Fb
Number Of Connections
Overall 64
Usable For Pg Communication
— Reserved For Pg Communication 1
Usable For Op Communication
— Reserved For Op Communication 1
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 12
Symbol-Related Messages Yes
Program Alarms Yes
Simultaneously Active Alarm-S Blocks, Max. 200; Alarm_S/Sq Blocks Or Alarm_D/Dq Blocks
Alarm 8-Blocks Yes
Number Of Instances For Alarm 8 And S7 Communication
Blocks, Max.1 800
Preset, Max. 600
Process Control Messages Yes
Number Of Archives That Can Log On Simultaneously (Sfb 37
Ar_Send)32
Number Of Messages
Overall, Max. 1 024
In 100 Ms Grid, Max. 128
In 500 Ms Grid, Max. 512
In 1000 Ms Grid, Max. 1 024
Number Of Additional Values
With 100 Ms Grid, Max. 1
With 500, 1000 Ms Grid, Max. 10
Test Commissioning Functions
Status Block Yes
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max. 70
Forcing
Forcing Yes
Forcing, Variables Inputs/Outputs, Bit Memories, Distributed I/Os
Number Of Variables, Max. 512
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Adjustable Yes
Preset 120
Configuration / Header
Configuration Software
Step 7 Yes
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
Access To Consistent Data In Process Image Yes
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Configuration / Programming / Number Of Simultaneously Active Sfc / Header
Dpsyc_Fr 2
D_Act_Dp 4
Rd_Rec 8
Wr_Rec 8
Wr_Parm 8
Parm_Mod 1
Wr_Dparm 2
Dpnrm_Dg 8
— Rdsysst 8; 1 To 8
Dp_Topol 1
Configuration / Programming / Number Of Simultaneously Active Sfb / Header
Rdrec 8
Wrrec 8
Know-How Protection
User Program Protection/Password Protection Yes

Dimensions

Width 25 Mm
Height 290 Mm
Depth 219 Mm
Weight S
Weight , Approx. 720 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible