This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7417-4HT14-0AB0

6ES7417-4HT14-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7417-4HT14-0AB0 Siemens

6ES7417-4HT14-0AB0 Siemens - ********** Replacement part ********* SIMATIC S7-400H, CPU 417H Central processing unit for S7-400H 4 interfaces: 1 MPI/DP, 1 DP and 2 for sync modules 30 MB memory (15 MB data/15 MB program)

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7417-4HT14-0AB0
Product Description ******* repair part ******* SIMATIC S7-400H, CPU 417H central processing unit for S7-400H 4 interfaces: 1 MPI/DP, 1 DP and 2 for sync modules 30 MB memory (15 MB data/15 MB program)
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 01.10.2023
Notes Product is no longer available Sucessor:For further information, see SIOS support ID:  59903098 If you need assistance please contact our local Siemens office

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) On request
Net Weight (kg) 1,154 Kg
Packaging Dimension 23,30 x 30,20 x 6,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4019169154383
UPC Not available
Commodity Code 85371091
LKZ_FDB/ CatalogID ST9.74
Product Group 4519
Group Code R1TP
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 21.09.2007
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Rated Value (Dc) Power Supply Via System Power Supply
Input Current
From Backplane Bus 5 V Dc, Typ. 1.5 A
From Backplane Bus 5 V Dc, Max. 1.8 A
From Backplane Bus 24 V Dc, Max. 150 Ma; Per Dp Interface
From Interface 5 V Dc, Max. 90 Ma; At Each Dp Interface
Power Loss
Power Loss , Typ. 6.5 W
Memory
Type Of Memory Ram
Work Memory
Integrated 30 Mbyte
Integrated (For Program) 15 Mbyte
Integrated (For Data) 15 Mbyte
Expandable No
Load Memory
Expandable Feprom Yes
Expandable Feprom, Max. 64 Mbyte
Integrated Ram, Max. 256 Kbyte
Expandable Ram Yes
Expandable Ram, Max. 64 Mbyte
Backup
Present Yes
With Battery Yes; All Data
Without Battery No
Battery
Backup Battery
Backup Current, Typ. 970 Μa; Valid Up To 40°C
Backup Current, Max. 1 980 Μa
Backup Time, Max. Dealt With In The Module Data Manual With The Secondary Conditions And The
Factors Of Influence
Feeding Of External Backup Voltage To Cpu 5 V Dc To 15 V Dc
Cpu Processing Times
For Bit Operations, Typ. 0.018 Μs
For Word Operations, Typ. 0.018 Μs
For Fixed Point Arithmetic, Typ. 0.018 Μs
For Floating Point Arithmetic, Typ. 0.054 Μs
Cpu-Blocks
Db
Number, Max. 8 191; Number Range: 1 - 8191
Size, Max. 64 Kbyte
Fb
Number, Max. 6 144; Number Range: 0 - 6143
Size, Max. 64 Kbyte
Fc
Number, Max. 6 144; Number Range: 0 - 6143
Size, Max. 64 Kbyte
Ob
Size, Max. 64 Kbyte
Number Of Time Alarm Obs 8
Number Of Delay Alarm Obs 4
Number Of Cyclic Interrupt Obs 9
Number Of Process Alarm Obs 8
Nesting Depth
Per Priority Class 24
Additional Within An Error Ob 2
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
— Preset No Times Retentive
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. Total Working And Load Memory (With Backup Battery)
Flag
Size, Max. 16 Kbyte
Retentivity Available Yes
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; In 1 Memory Byte
Local Data
Adjustable, Max. 64 Kbyte
Preset 32 Kbyte
Address Area
I/O Address Area
Inputs 16 Kbyte
Outputs 16 Kbyte
Process Image
Inputs, Adjustable 16 Kbyte
Outputs, Adjustable 16 Kbyte
Inputs, Default 1 024 Byte
Outputs, Default 1 024 Byte
Consistent Data, Max. 244 Byte
Access To Consistent Data In Process Image Yes
Subprocess Images
Number Of Subprocess Images, Max. 15
Digital Channels
Inputs 131 072
— Of Which Central 131 072
Outputs 131 072
— Of Which Central 131 072
Analog Channels
Inputs 8 192
— Of Which Central 8 192
Outputs 8 192
— Of Which Central 8 192
Hardware Configuration
Number Of Expansion Units, Max. 21
Connectable Ops 63 Without Message Processing, 16 With Message Processing
Multicomputing No
Interface Modules
Number Of Connectable Ims (Total), Max. 6
Number Of Connectable Im 460S, Max. 6
Number Of Connectable Im 463S, Max. 4; Single Mode Only
Number Of Dp Masters
Integrated 2
Via Cp 10
Mixed Mode Im + Cp Permitted No
Number Of Operable Fms And Cps (Recommended)
Fm See Manual Automation System S7-400H Fault-Tolerant Systems. Limited By
Number Of Slots And Number Of Connections
Cp, Ptp See Manual Automation System S7-400H Fault-Tolerant Systems. Limited By
Number Of Slots And Number Of Connections
Profibus And Ethernet Cps 14; Of Which Max. 10 Cp As Dp Master
Slots
Required Slots 2
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Resolution 1 Ms
Deviation Per Day (Buffered), Max. 1.7 S; Power Off
Deviation Per Day (Unbuffered), Max. 8.6 S; Power On
Operating Hours Counter
Number 8
Number/Number Range 0 To 7
Range Of Values 0 To 32767 Hours
Granularity 1 H
Retentive Yes
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
Time Difference In System When Synchronizing Via
Mpi, Max. 200 Ms
Interfaces
Number Of Rs 485 Interfaces 2
Number Of Other Interfaces 0
Optical Interface No
1. Interface
Interface Type Mpi/Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device No
Mpi
Number Of Connections 44
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
Profibus Dp Master
Number Of Connections, Max. 32
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance No
— Sync/Freeze No
— Activation/Deactivation Of Dp Devices No
— Direct Data Exchange (Slave-To-Slave
Communication )No
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
2. Interface
Interface Type Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Profibus Dp Master Yes
Profibus Dp Device No
Profibus Dp Master
Number Of Connections, Max. 32
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 125
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— Equidistance No
— Sync/Freeze No
— Direct Data Exchange (Slave-To-Slave
Communication )No
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
3. Interface
Interface Type Pluggable Synchronization Submodule (Fo)
Plug-In Interface Modules Synchronization Submodule If 960 6Es7960-1Aa04-0Xa0 Or 6Es7960-1Ab04-
0Xa0
4. Interface
Interface Type Pluggable Synchronization Submodule (Fo)
Plug-In Interface Modules Synchronization Submodule If 960 6Es7960-1Aa04-0Xa0 Or 6Es7960-1Ab04-
0Xa0
Communication Functions / Header
Pg/Op Communication Yes
Number Of Connectable Ops Without Message Processing 63
Number Of Connectable Ops With Message Processing 16
Global Data Communication
Supported No
S7 Basic Communication
Supported No
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. 64 Kbyte
User Data Per Job (Of Which Consistent), Max. 462 Byte; 1 Variable
S5 Compatible Communication
Supported Yes; (Via Cp Max. 10 And Fc Ag_Send And Fc Ag_Recv)
User Data Per Job, Max. 8 Kbyte
User Data Per Job (Of Which Consistent), Max. 240 Byte
Number Of Simultaneous Ag-Send/Ag-Recv Orders Per
Cpu, Max.64/64
Standard Communication (Fms)
Supported Yes; Via Cp And Loadable Fb
Number Of Connections
Overall 64
Usable For Pg Communication
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Max. 0
Usable For Op Communication
— Reserved For Op Communication 1
— Adjustable For Op Communication, Max. 0
Usable For S7 Basic Communication
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Max. 0
Usable For S7 Communication
— Reserved For S7 Communication 0
— Adjustable For S7 Communication, Max. 0
Usable For Routing 0
— Reserved For Routing 0
— Adjustable For Routing, Max. 0
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 16
Symbol-Related Messages No
Program Alarms Yes
Simultaneously Active Alarm-S Blocks, Max. 200
Alarm 8-Blocks Yes
Number Of Instances For Alarm 8 And S7 Communication
Blocks, Max.10 000
Preset, Max. 1 200
Process Control Messages Yes
Number Of Archives That Can Log On Simultaneously (Sfb 37
Ar_Send)64
Test Commissioning Functions
Status Block Yes
Single Step Yes
Number Of Breakpoints 4
Status/Control
Status/Control Variable Yes
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max. 70
Forcing
Forcing Yes
Forcing, Variables Inputs/Outputs, Bit Memories, Distributed I/Os
Number Of Variables, Max. 512
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Adjustable Yes
Preset 120
Configuration / Header
Configuration Software
Step 7 Yes
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 8
Access To Consistent Data In Process Image Yes
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Configuration / Programming / Number Of Simultaneously Active Sfc / Header
Rd_Rec 8
Wr_Rec 8
Wr_Parm 8
Parm_Mod 1
Wr_Dparm 2
Dpnrm_Dg 8
Rdsysst 8
Dp_Topol 1
Configuration / Programming / Number Of Simultaneously Active Sfb / Header
Rdrec 8
Wrrec 8
Know-How Protection
User Program Protection/Password Protection Yes

Dimensions

Width 50 Mm
Height 290 Mm
Depth 219 Mm
Weight S
Weight , Approx. 995 G