This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7417-4XT07-0AB0

6ES7417-4XT07-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7417-4XT07-0AB0 Siemens

6ES7417-4XT07-0AB0 Siemens - SIMATIC S7-400, CPU 417-4 Central processing unit with: Work memory 32 MB, (16 MB code; 16 MB data) 1st interface MPI 12 Mbit/s; 2nd interface PROFIBUS DP, 3rd/4th interface plug-in IFM module

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7417-4XT07-0AB0
Product Description SIMATIC S7-400, CPU 417-4 Central processing unit with: Work memory 32 MB, (16 MB code; 16 MB data) 1st interface MPI 12 Mbit/s; 2nd interface PROFIBUS DP, 3rd/4th interface plug-in IFM module
Product family CPU 417
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 1,057 Kg
Packaging Dimension 23,30 x 30,20 x 6,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047622193877
UPC 804766222924
Commodity Code 85371091
LKZ_FDB/ CatalogID ST74
Product Group 4040
Group Code R338
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 19.11.2015
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 4,4'-isopropylidened... CAS-No. 80-05-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 4,4'-isopropylidenediphenol (Bisphenol A, BPA) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes; For Profibus Only
Engineering With
Programming Package Step 7 V5.4 Or Higher With Hsp 261
Cir - Configuration In Run
Cir Synchronization Time, Basic Load 60 Ms
Cir Synchronization Time, Time Per I/O Byte 7 Μs

Supply Voltage

Rated Value (Dc) Power Supply Via System Power Supply
Input Current
From Backplane Bus 5 V Dc, Typ. 1.3 A
From Backplane Bus 5 V Dc, Max. 1.6 A
From Backplane Bus 24 V Dc, Max. 600 Ma; 150 Ma Per Dp Interface
From Interface 5 V Dc, Max. 90 Ma; At Each Dp Interface
Power Loss
Power Loss , Typ. 6.5 W
Memory
Type Of Memory Ram
Work Memory
Integrated 32 Mbyte
Integrated (For Program) 16 Mbyte
Integrated (For Data) 16 Mbyte
Expandable No
Load Memory
Expandable Feprom Yes; With Memory Card (Flash)
Expandable Feprom, Max. 64 Mbyte
Integrated Ram, Max. 1 Mbyte
Expandable Ram Yes; With Memory Card (Ram)
Expandable Ram, Max. 64 Mbyte
Backup
Present Yes
With Battery Yes; All Data
Without Battery No
Battery
Backup Battery
Backup Current, Typ. 225 Μa; Up To 40 °C
Backup Current, Max. 1 275 Μa
Backup Time, Max. See Reference Manual, Module Data, Chapter 3.3
Feeding Of External Backup Voltage To Cpu 5 V Dc To 15 V Dc
Cpu Processing Times
For Bit Operations, Typ. 7.5 Ns
For Word Operations, Typ. 7.5 Ns
For Fixed Point Arithmetic, Typ. 7.5 Ns
For Floating Point Arithmetic, Typ. 15 Ns
Cpu-Blocks
Db
Number, Max. 16 000; Number Range: 1 To 16000
Size, Max. 64 Kbyte
Fb
Number, Max. 8 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Fc
Number, Max. 8 000; Number Range: 0 To 7999
Size, Max. 64 Kbyte
Ob
Number, Max. See Instruction List
Size, Max. 64 Kbyte
Number Of Free Cycle Obs 1; Ob 1
Number Of Time Alarm Obs 8; Ob 10-17
Number Of Delay Alarm Obs 4; Ob 20-23
Number Of Cyclic Interrupt Obs 9; Ob 30-38 (Shortest Cycle That Can Be Set = 500 Μs)
Number Of Process Alarm Obs 8; Ob 40-47
Number Of Dpv1 Alarm Obs 3; Ob 55-57
Number Of Isochronous Mode Obs 4; Ob 61-64
Number Of Multicomputing Obs 1; Ob 60
Number Of Background Obs 1; Ob 90
Number Of Startup Obs 3; Ob 100-102
Number Of Asynchronous Error Obs 9; Ob 80-88
Number Of Synchronous Error Obs 2; Ob 121, 122
Nesting Depth
Per Priority Class 24
Additional Within An Error Ob 2
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
— Preset Z 0 To Z 7
Counting Range
— Lower Limit 0
— Upper Limit 999
Iec Counter
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
— Preset No Times Retentive
Time Range
— Lower Limit 10 Ms
— Upper Limit 9 990 S
Iec Timer
Present Yes
Type Sfb
Number Unlimited (Limited Only By Ram Capacity)
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. Total Working And Load Memory (With Backup Battery)
Flag
Size, Max. 16 Kbyte; Size Of Bit Memory Address Area
Retentivity Available Yes
Retentivity Preset Mb 0 To Mb 15
Number Of Clock Memories 8; In 1 Memory Byte
Local Data
Adjustable, Max. 64 Kbyte
Preset 32 Kbyte
Address Area
I/O Address Area
Inputs 16 Kbyte
Outputs 16 Kbyte
Process Image
Inputs, Adjustable 16 Kbyte
Outputs, Adjustable 16 Kbyte
Inputs, Default 1 024 Byte
Outputs, Default 1 024 Byte
Consistent Data, Max. 244 Byte
Access To Consistent Data In Process Image Yes
Subprocess Images
Number Of Subprocess Images, Max. 15
Digital Channels
Inputs 131 072
— Of Which Central 131 072
Outputs 131 072
— Of Which Central 131 072
Analog Channels
Inputs 8 192
— Of Which Central 8 192
Outputs 8 192
— Of Which Central 8 192
Hardware Configuration
Number Of Expansion Units, Max. 21
Connectable Ops 119
Multicomputing Yes; 4 Cpus Max. (With Ur1 Or Ur2)
Interface Modules
Number Of Connectable Ims (Total), Max. 6
Number Of Connectable Im 460S, Max. 6
Number Of Connectable Im 463S, Max. 4; Im 463-2
Number Of Dp Masters
Integrated 2
Via Cp 10; Cp 443-5 Extended
Via Im 467 4
Mixed Mode Im + Cp Permitted No; Im 467 Cannot Be Used Jointly With Cp 443-5 Ext. Or Cp 443-1 In
Profinet Io Mode
Via Interface Module 2
Number Of Pluggable S5 Modules (Via Adapter Capsule In
Central Device), Max.6
Number Of Io Controllers
Integrated 0
Via Cp 4; Max. 4 In The Central Controller; No Mixed Operation Of Different Cp 443-1
Types In Profinet Io Mode
Number Of Operable Fms And Cps (Recommended)
Fm Limited By Number Of Slots And Number Of Connections
Cp, Ptp Cp 440: Limited By Number Of Slots; Cp 441: Limited By Number Of Connections
Profibus And Ethernet Cps 14; Of Which 10 Cps Max. Or Ims As Dp Master, 4 Profinet Controller
Maximum
Slots
Required Slots 2
Time Of Day
Clock
Hardware Clock (Real-Time) Yes
Retentive And Synchronizable Yes
Resolution 1 Ms
Deviation Per Day (Buffered), Max. 1.7 S; Power Off
Deviation Per Day (Unbuffered), Max. 8.6 S; For Power On
Operating Hours Counter
Number 16
Number/Number Range 0 To 15
Range Of Values Sfcs 2, 3 And 4: 0 To 32767 Hours Sfc 101: 0 To 2^31 - 1 Hours
Granularity 1 H
Retentive Yes
Clock Synchronization
Supported Yes
To Mpi, Master Yes
On Mpi, Device Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp No; Via Cp
To If 964 Dp Yes
Time Difference In System When Synchronizing Via
Mpi, Max. 200 Ms
Interfaces
Interfaces/Bus Type 1 X Mpi/Profibus Dp, 1 X Profibus Dp, 2 X Profibus Dp (Optionally
Pluggable)
Number Of Rs 485 Interfaces 2; Combined Mpi / Profibus Dp And Profibus Dp
Number Of Other Interfaces 2; Profibus Dp With If 964-Dp (Plug-In Option; Mlfb: 6Es7964-2Aa04-
0Ab0)
1. Interface
Interface Type Mpi/Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi Yes
Profibus Dp Master Yes
Profibus Dp Device Yes
Mpi
Number Of Connections 44; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Services
— Pg/Op Communication Yes
— Routing Yes
— Global Data Communication Yes
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
Profibus Dp Master
Number Of Connections, Max. 32; If A Diagnostics Repeater Is Used On The Line, The Number Of Connection
Resources On The Line Is Reduced By 1
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 32
Services
— Pg/Op Communication Yes
— Routing Yes; S7 Routing
— Global Data Communication No
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 2 Kbyte
— Outputs, Max. 2 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
1St Interface / Profibus Dp Device / Header
Number Of Connections 32
Gsd File Http://Support.Automation.Siemens.Com/Ww/View/En/113652
Transmission Rate, Max. 12 Mbit/S
Automatic Baud Rate Search No
Address Area, Max. 32; Virtual Slots
User Data Per Address Area, Max. 32 Byte
— Of Which Consistent, Max. 32 Byte
Services
— Pg/Op Communication Yes; With Interface Active
— Routing Yes; With Interface Active
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
2. Interface
Interface Type Profibus Dp
Isolated Yes
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Profibus Dp Master Yes
Profibus Dp Device Yes
Profibus Dp Master
Number Of Connections, Max. 32
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 125
Services
— Pg/Op Communication Yes
— Routing Yes; S7 Routing
— Global Data Communication No
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
2Nd Interface / Profibus Dp Device / Header
Number Of Connections 32
Gsd File Http://Support.Automation.Siemens.Com/Ww/View/En/113652
Transmission Rate, Max. 12 Mbit/S
Address Area, Max. 32
User Data Per Address Area, Max. 32 Byte
— Of Which Consistent, Max. 32 Byte
Services
— Routing Yes; With Interface Active
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
3. Interface
Interface Type Pluggable Interface Module (If), Technical Data As For 2Nd Interface
Plug-In Interface Modules If 964-Dp (Mlfb: 6Es7964-2Aa04-0Ab0)
Isolated Yes
Automatic Detection Of Transmission Rate No
Interface Types
Rs 485 Yes
Output Current Of The Interface, Max. 150 Ma
Protocols
Mpi No
Profibus Dp Master Yes
Profibus Dp Device Yes
Profibus Dp Master
Number Of Connections, Max. 32
Transmission Rate, Max. 12 Mbit/S
Max. Number Of Dp Devices 125
Services
— Pg/Op Communication Yes
— Routing Yes; S7 Routing
— Global Data Communication No
— S7 Basic Communication Yes
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Equidistance Yes
— Isochronous Mode Yes
— Sync/Freeze Yes
— Activation/Deactivation Of Dp Devices Yes
— Direct Data Exchange (Slave-To-Slave
Communication )Yes
— Dpv0 Yes
— Dpv1 Yes
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
User Data Per Dp Device
— User Data Per Dp Device, Max. 244 Byte
— Inputs, Max. 244 Byte
— Outputs, Max. 244 Byte
— Slots, Max. 244
— Per Slot, Max. 128 Byte
3Rd Interface / Profibus Dp Device / Header
Number Of Possible Connections / At The 3Rd Interface / As
Dp Slave32
Gsd File Http://Support.Automation.Siemens.Com/Ww/View/En/113652
Transfer Rate / At The 3Rd Interface / As Dp Slave /
Maximum 12 Mbit/S
Automatic Baud Rate Search No
Address Area, Max. 32
Data Volume / At The 3Rd Interface / As Dp Slave / As User
Data Per Address Range / Maximum32 Byte
— Data Volume / At The 3Rd Interface / As Dp Slave / As
Consistent Reference Data Per Address Range /
Maximum 32 Byte
Services
— Pg/Op Communication Yes
— Routing Yes; With Interface Active
— Global Data Communication No
— S7 Basic Communication No
— S7 Communication Yes
— S7 Communication, As Client Yes
— S7 Communication, As Server Yes
— Direct Data Exchange (Slave-To-Slave
Communication )No
— Dpv1 No
Transfer Memory
— Inputs 244 Byte
— Outputs 244 Byte
4. Interface
Interface Type Pluggable Interface Module (If), Technical Data As For 2Nd Interface
Plug-In Interface Modules If 964-Dp (Mlfb: 6Es7964-2Aa04-0Ab0)
Protocols
Simatic Communication
S7 Routing Yes
Open Ie Communication
Iso-On-Tcp (Rfc1006) Via Cp 443-1 And Loadable Fb
— Data Length, Max. 1 452 Bytes Via Cp 443-1 Adv.
Web Server
Supported No
Isochronous Mode
Equidistance Yes
Number Of Dp Masters With Isochronous Mode 4
User Data Per Isochronous Slave, Max. 244 Byte
Shortest Clock Pulse 1 Ms; 0.5 Ms Without Use Of Sfc 126, 127
Max. Cycle 32 Ms
Communication Functions / Header
Pg/Op Communication Yes
Number Of Connectable Ops Without Message Processing 119
Number Of Connectable Ops With Message Processing 119; When Using Alarm_S/Sq And Alarm_D/Dq
Data Record Routing Yes
Global Data Communication
Supported Yes
Number Of Gd Loops, Max. 16
Number Of Gd Packets, Transmitter, Max. 16
Number Of Gd Packets, Receiver, Max. 32
Size Of Gd Packets, Max. 54 Byte
Size Of Gd Packet (Of Which Consistent), Max. 1 Variable
S7 Basic Communication
Supported Yes
User Data Per Job, Max. 76 Byte
User Data Per Job (Of Which Consistent), Max. 1 Variable
S7 Communication
Supported Yes
As Server Yes
As Client Yes
User Data Per Job, Max. 64 Kbyte
User Data Per Job (Of Which Consistent), Max. 462 Byte; 1 Variable
S5 Compatible Communication
Supported Yes; Via Fc Ag_Send And Ag_Recv, Max. Via 10 Cp 443-1 Or 443-5
User Data Per Job, Max. 8 Kbyte
User Data Per Job (Of Which Consistent), Max. 240 Byte
Number Of Simultaneous Ag-Send/Ag-Recv Orders Per
Cpu, Max.64/64
Standard Communication (Fms)
Supported Yes; Via Cp And Loadable Fb
Number Of Connections
Overall 120
Usable For Pg Communication 119
— Reserved For Pg Communication 1
— Adjustable For Pg Communication, Max. 0
Usable For Op Communication 119
— Reserved For Op Communication 1
— Adjustable For Op Communication, Max. 0
Usable For S7 Basic Communication 118
— Reserved For S7 Basic Communication 0
— Adjustable For S7 Basic Communication, Max. 0
Usable For S7 Communication 118
— Reserved For S7 Communication 0
— Adjustable For S7 Communication, Max. 0
Usable For Routing 59
— Reserved For Routing 0
— Adjustable For Routing, Max. 0
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 119; Max. 119 With Alarm_S/Sq And Alarm_D/Dq (Ops); Max. 16 With Alarm,
Alarm_8, Alarm_8P, Notify And Notify_8 (E.G. Wincc)
Symbol-Related Messages Yes
Scan Procedure Yes
Program Alarms Yes
Process Diagnostic Messages Yes
Simultaneously Active Alarm-S Blocks, Max. 1 000; Simultaneously Active Alarm_S/Sq Blocks Or Alarm_D/Dq Blocks
Alarm 8-Blocks Yes
Number Of Instances For Alarm 8 And S7 Communication
Blocks, Max.10 000
Preset, Max. 1 200
Process Control Messages Yes
Number Of Archives That Can Log On Simultaneously (Sfb 37
Ar_Send)64
Number Of Messages
Overall, Max. 1 024
In 100 Ms Grid, Max. 128
In 500 Ms Grid, Max. 512
In 1000 Ms Grid, Max. 1 024
Number Of Additional Values
With 100 Ms Grid, Max. 1
With 500, 1000 Ms Grid, Max. 10
Test Commissioning Functions
Status Block Yes; Up To 16 Simultaneously
Single Step Yes
Number Of Breakpoints 16
Status/Control
Status/Control Variable Yes; Up To 16 Variable Tables
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max. 70; Status/Control
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs, Bit Memories, Peripheral Inputs, Peripheral Outputs
Number Of Variables, Max. 512
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Adjustable Yes
Preset 120
Service Data
Can Be Read Out Yes
Standards, Approvals, Certificates
Ce Mark Yes
Csa Approval Yes
Ul Approval Yes
Culus Yes
Fm Approval Yes
Rcm (Formerly C-Tick) Yes
Kc Approval Yes
Eac (Formerly Gost-R) Yes
Use In Hazardous Areas
Atex Atex Ii 3G Ex Na Iic T4 Gc

Ambient Temperature During Operation

Min. 0 °C
Max. 60 °C
Configuration / Header
Configuration Software
Step 7 Yes
Configuration / Programming / Header
Command Set See Instruction List
Nesting Levels 7
Access To Consistent Data In Process Image Yes
System Functions (Sfc) See Instruction List
System Function Blocks (Sfb) See Instruction List
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Cfc Yes
— Graph Yes
— Higraph® Yes
Configuration / Programming / Number Of Simultaneously Active Sfc / Header
— Dpsyc_Fr 2; Sfc 11; Per Interface
— D_Act_Dp 8; Sfc 12; Per Interface
— Rd_Rec 8; Sfc 59; Per Interface
— Wr_Rec 8; Sfc 58; Per Interface
— Wr_Parm 8; Sfc 55; Per Interface
— Parm_Mod 1; Sfc 57; Per Interface
— Wr_Dparm 2; Sfc 56; Per Interface
— Dpnrm_Dg 8; Sfc 13; Per Interface
— Rdsysst 8; Sfc 51
— Dp_Topol 1; Sfc 103; Per Interface
Configuration / Programming / Number Of Simultaneously Active Sfb / Header
— Rdrec 8; Sfb 52; Per Interface, But Not More Than 32 Across All External Interfaces
— Wrrec 8; Sfb 53; Per Interface, But Not More Than 32 Across All External Interfaces
Know-How Protection
User Program Protection/Password Protection Yes
Block Encryption Yes; With S7 Block Privacy

Dimensions

Width 50 Mm
Height 290 Mm
Depth 219 Mm
Weight S
Weight , Approx. 900 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible