This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7422-7BL00-0AB0

6ES7422-7BL00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7422-7BL00-0AB0 Siemens

6ES7422-7BL00-0AB0 Siemens - SIMATIC S7-400, digital output SM 422, isolated 32 DO; 24 V DC, 0.5 A with 0.15 ms output delay, diagnostics

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7422-7BL00-0AB0
Product Description SIMATIC S7-400, digital output SM 422, isolated 32 DO; 24 V DC, 0.5 A with 0.15 ms output delay, diagnostics
Product family SM 422 digital output module
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,842 Kg
Packaging Dimension 23,30 x 30,20 x 3,80
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515128953
UPC 662643185126
Commodity Code 85389091
LKZ_FDB/ CatalogID ST74
Product Group 4041
Group Code R338
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.03.2008
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Input Current
From Load Voltage L+ (Without Load), Max. 120 Ma
From Backplane Bus 5 V Dc, Max. 200 Ma
Power Loss
Power Loss , Typ. 8 W
Digital Outputs
Number Of Digital Outputs 32
Short-Circuit Protection Yes; Clocked Electronically
Response Threshold, Typ. 0.75 To 1.5 A
Limitation Of Inductive Shutdown Voltage To L+ (-45 V)
Control Ling A Digital Input Yes; Possible
Switching Capacity Of The Outputs
On Lamp Load, Max. 5 W
Load Resistance Range
Lower Limit 48 Ω
Upper Limit 4 Kω
Output Voltage
For Signal "1", Min. L+ (-0.8 V)
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "1" Permissible Range, Min. 5 Ma
For Signal "1" Permissible Range, Max. 600 A
For Signal "0" Residual Current, Max. 0.5 Ma
Parallel Switching Of Two Outputs
For Uprating Yes; Possible (Only Outputs Of The Same Group)
For Redundant Control Of A Load Yes; Possible (Only Outputs Of The Same Group)
Switching Frequency
With Resistive Load, Max. 100 Hz
With Inductive Load, Max. 2 Hz
With Inductive Load (Acc. To Iec 60947-5-1, Dc13), Max. 2 Hz
On Lamp Load, Max. 2 Hz
Total Current Of The Outputs (Per Group)
All Mounting Positions
— Up To 40 °C, Max. 4 A
— Up To 60 °C, Max. 2 A
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Hardware Interrupt Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes
Wire-Break Yes; <0.15 Ma
Short-Circuit Yes; > 1 A (Typ.)
Diagnostics Indication Led
Internal Fault Intf (Red) Yes
External Fault Extf (Red) Yes
Status Indicator Digital Output (Green) Yes
Potential Separation
Potential Separation Digital Outputs
Between The Channels Yes
Between The Channels, In Groups Of 8
Between The Channels And Backplane Bus Yes
Isolation
Isolation Tested With 500 V Dc

Dimensions

Width 25 Mm
Height 290 Mm
Depth 210 Mm
Weight S
Weight , Approx. 600 G