This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7431-0HH00-0AB0

6ES7431-0HH00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7431-0HH00-0AB0 Siemens

6ES7431-0HH00-0AB0 Siemens - SIMATIC S7-400, analog input SM 431, non-isolated 16 AI, resolution 13 bit, +/-10 V, +/-20 mA, 4 - 20 mA 20 ms conversion time

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7431-0HH00-0AB0
Product Description SIMATIC S7-400, analog input SM 431, non-isolated 16 AI, resolution 13 bit, +/-10 V, +/-20 mA, 4 - 20 mA 20 ms conversion time
Product family SM 431 analog input module
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,826 Kg
Packaging Dimension 23,30 x 30,10 x 3,80
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515128960
UPC 662643184266
Commodity Code 85389091
LKZ_FDB/ CatalogID ST74
Product Group 4041
Group Code R338
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 01.03.2008
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V; Only Required For Supplying 2-Wire Transmitters
Reverse Polarity Protection Yes
Input Current
From Load Voltage L+ (Without Load), Max. 400 Ma; For 16 Connected, Fully Controlled 2-Wire Transmitters
From Backplane Bus 5 V Dc, Max. 100 Ma
Power Loss
Power Loss , Typ. 2 W

Analog Inputs

Number Of Analog Inputs 16
For Voltage/Current Measurement 16
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.20 V; 20 V Dc Permanent, 75 V Dc For Max. 1 S (Duty Factor 1:20)
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Constant Measurement Current For Resistance-Type Transmitter,
Typ.1.67 Ma
Input Ranges
Voltage Yes
Current Yes
Thermocouple No
Resistance Thermometer No
Resistance No
Input Ranges (Rated Values), Voltages
1 V To 5 V Yes
— Input Resistance (1 V To 5 V) 100 K Ω
-1 V To +1 V Yes
— Input Resistance (-1 V To +1 V) 10 M Ω
-10 V To +10 V Yes
— Input Resistance (-10 V To +10 V) 100 K Ω
Input Ranges (Rated Values), Currents
-20 Ma To +20 Ma Yes
— Input Resistance (-20 Ma To +20 Ma) 50 Ω
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 50 Ω
Cable Length
Shielded, Max. 200 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 13 Bit
Integration Time, Parameterizable Yes
Basic Conversion Time (Ms) 55 / 65 Ms
Integration Time (Ms) 50 / 60 Ms
Interference Voltage Suppression For Interference
Frequency F1 In Hz50 / 60 Hz
Basic Execution Time Of The Module (All Channels
Released)1 040 Ms; 880 / 1 040 Ms
Encoder
Connection Of Signal Encoders
For Voltage Measurement Yes; Possible
For Current Measurement As 4-Wire Transducer Yes
Errors/Accuracies
Temperature Error (Relative To Input Range), (+/-) 0.01 %/K
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Input Range, (+/-) 0.65 %; 1.0 % At 1 To 5 V; 0.65 % At ±1 V, ±10 V
Current, Relative To Input Range, (+/-) 0.65 %
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Input Range, (+/-) 0.25 %; 0.5% At 1 To 5 V; 0.25% At ±1 V, ±10 V
Current, Relative To Input Range, (+/-) 0.25 %; At ±20 Ma, 4 To 20 Ma
Interrupts/Diagnostics/Status Information
Diagnostics Function No
Potential Separation
Potential Separation Analog Inputs
Potential Separation Analog Inputs No
Between The Channels No
Between The Channels And Backplane Bus No
Between The Channels And Load Voltage L+ No
Isolation
Isolation Tested With 500 V Ac/707 V Dc, Type Test

Dimensions

Width 25 Mm
Height 290 Mm
Depth 210 Mm
Weight S
Weight , Approx. 500 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible