This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7431-7KF10-0AB0

6ES7431-7KF10-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7431-7KF10-0AB0 Siemens

6ES7431-7KF10-0AB0 Siemens - SIMATIC S7-400, analog input SM 431, 8 AI, resolution 16 bit, resistor/PT100/NI100 isolated, diagnostics alarm, 20 ms conversion time

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7431-7KF10-0AB0
Product Description SIMATIC S7-400, analog input SM 431, 8 AI, resolution 16 bit, resistor/PT100/NI100 isolated, diagnostics alarm, 20 ms conversion time
Product family SM 431 analog input module
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 5 Day/Days
Net Weight (kg) 0,761 Kg
Packaging Dimension 23,50 x 29,80 x 4,30
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4019169026864
UPC 662643183603
Commodity Code 85389091
LKZ_FDB/ CatalogID ST74
Product Group 4041
Group Code R338
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 02.06.2017
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Analog Inputs

Number Of Analog Inputs 8
For Resistance Measurement 8
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.35 V; 35 V Continuous, 75 V For Max. 1 S (Mark To Space Ratio 1:20)
Constant Measurement Current For Resistance-Type Transmitter,
Typ.1 Ma
Input Ranges
Voltage No
Current No
Thermocouple No
Resistance Thermometer Yes
Resistance Yes
Input Ranges (Rated Values), Resistance Thermometer
Ni 100 Yes
— Input Resistance (Ni 100) > 10 000 Ohms
Ni 1000 Yes; Different Characteristics Selectable: Europe/U.S.
— Input Resistance (Ni 1000) > 10 000 Ohms
Pt 100 Yes
— Input Resistance (Pt 100) > 10 000 Ohms
Pt 1000 Yes
— Input Resistance (Pt 1000) > 10 000 Ohms
Pt 200 Yes
— Input Resistance (Pt 200) > 10 000 Ohms
Pt 500 Yes
— Input Resistance (Pt 500) > 10 000 Ohms
Characteristic Linearization
Parameterizable Yes
— For Resistance Thermometer Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000; Different Characteristics Selectable
(Europe/U.S.)
Cable Length
Shielded, Max. 200 M; 50 M With Thermocouples And Input Ranges ±80 Mv
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit
Integration Time, Parameterizable Yes
Basic Conversion Time (Ms) 8 / 23 / 25 Ms
Integration Time (Ms) 20 Ms At 50 Hz (Entire Module Incl. Wire Break)
Interference Voltage Suppression For Interference
Frequency F1 In Hznone/ 60 / 50 Hz
Basic Execution Time Of The Module (All Channels
Released)8 Ms; 8 / 23 / 25 Ms
Encoder
Connection Of Signal Encoders
For Resistance Measurement With Three-Wire Connection Yes
For Resistance Measurement With Four-Wire Connection Yes
Errors/Accuracies
Operation Al Error Limit In Overall Temperature Range
Resistance Thermometer, Relative To Input Range, (+/-) ±1 °C
Basic Error Limit (Operational Limit At 25 °C)
Resistance Thermometer, Relative To Input Range, (+/-) ±0,2 °C
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes; Parameterizable
Alarms
Diagnostic Alarm Yes; Parameterizable
Limit Value Alarm Yes
Hardware Interrupt Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes; Possible
Potential Separation
Potential Separation Analog Inputs
Potential Separation Analog Inputs Yes; Internal/External
Between The Channels No
Between The Channels And Backplane Bus Yes
Isolation
Isolation Tested With 500 V Dc

Dimensions

Width 25 Mm
Height 290 Mm
Depth 210 Mm
Weight S
Weight , Approx. 650 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible