Description for 6ES7450-1AP00-0AE0 Siemens

6ES7450-1AP00-0AE0 Siemens - ********** Replacement part ********* SIMATIC S7-400, Function module FM 450-1 for counter function with 2 channels, incl. configuration package on CD

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7450-1AP00-0AE0
Product Description ******* repair part ******* SIMATIC S7-400, function module FM 450-1 for counter function with 2 channels incl. configuration package on CD
Product family Not available
Product Lifecycle (PLM) PM490:Start of final year of support
PLM Effective Date Product discontinued since: 24.07.2024
Notes Product is no longer available. Successor: 6ES7450-1AP01-0AE0 Compare Products

Successor information

Successor 6ES7450-1AP01-0AE0
Successor Description SIMATIC S7-400, function module FM 450-1 for counter function with 2 channels incl. configuration package on CD

Delivery information

Export Control Regulations ECCN : EAR99H / AL : N
Estimated dispatch time (Working Days) On request
Net Weight (kg) 0,808 Kg
Packaging Dimension 23,30 x 30,20 x 4,10
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515129271
UPC 662643183658
Commodity Code 85389091
LKZ_FDB/ CatalogID ST9-E5
Product Group 4519
Group Code R1TP
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.12.2008
Product class D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Supply Voltage

Auxiliary Voltage 1L+, Load Voltage 2L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V; Dynamic 18.5 V
Permissible Range, Upper Limit (Dc) 28.8 V; Dynamic 30.2 V
Input Current
From Load Voltage 1L+ (Without Load), Max. 40 Ma
From Backplane Bus 5 V Dc, Max. 450 Ma
Encoder Supply
5 V Encoder Supply
5 V Yes; 5.2 V ±2 %
Short-Circuit Protection Yes
Output Current, Max. 300 Ma
24 V Encoder Supply
24 V Yes; 1L+ (-3 V)
Short-Circuit Protection Yes
Output Current, Max. 300 Ma
Power Loss
Power Loss , Typ. 9 W
Digital Inputs
Number Of Digital Inputs 6
Functions 1 For Gate Start, 1 For Gate Stop, 1 For Setting The Counter
Input Voltage
For Signal "0" -28.8 ... +5V
For Signal "1" +11 To +28.8V
Input Current
For Signal "1", Typ. 9 Ma
Input Delay (For Rated Value Of Input Voltage)
Input Frequency (With A Time Delay Of 0.1 Ms), Max. 200 Khz
For Standard Inputs
— Parameterizable Yes
— At "0" To "1", Max. 2.5 Μs; ≥ 2.5 Μs (200 Khz); ≤ 25 Μs (20 Khz)
Digital Outputs
Number Of Digital Outputs 4
Short-Circuit Protection Yes; Clocked Electronically
Limitation Of Inductive Shutdown Voltage To 2L+ (-39 V)
Output Voltage
For Signal "0", Max. 3 V
For Signal "1", Min. 2L+ (-1,5 V)
Output Current
For Signal "1" Rated Value 0.5 A
For Signal "1" Permissible Range For 0 To 60 °C, Min. 5 Ma
For Signal "1" Permissible Range For 0 To 60 °C, Max. 0.6 A
Output Delay With Resistive Load
"0" To "1", Max. 300 Μs
Encoder
Connectable Encoders
Incremental Encoder (Symmetrical) Yes; With 2 Pulse Trains Offset By 90°
Incremental Encoder (Asymmetrical) Yes
24 V Initiator Yes
24 V Directional Element Yes; 1 Pulse Train, 1 Direction Level
Interrupts/Diagnostics/Status Information
Status Indicator Yes; 14 Green Leds For Status Of Cr, Dir, Inputs And Outputs
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes; Parameterizable
Hardware Interrupt Yes; Parameterizable
Diagnoses
Diagnostic Information Readable Yes
Diagnostics Indication Led
Internal Fault Intf (Red) Yes
External Fault Extf (Red) Yes
Status Indicator Digital Input (Green) Yes
Status Indicator Digital Output (Green) Yes
Counter
Number Of Counter Inputs 2; 32 Bit Or ±31 Bit
Counter Input 5 V
Type Rs 422
Terminating Resistor 220 Ω
Differential Input Voltage Min. 0.5 V
Counting Frequency, Max. 500 Khz
Counter Input 24 V
Input Voltage For Signal "0" -30 To +5 V
Input Voltage For Signal "1" +11 To +30V
Input Current For Signal "1", Typ. 9 Ma
Counting Frequency, Max. 200 Khz
Minimum Pulse Width ≥ 2.5 Μs (200 Khz); ≥ 25 Μs (20 Khz) (Parameterizable)
Potential Separation
Potential Separation Digital Inputs
Between The Channels And Backplane Bus Yes; Optocoupler
Potential Separation Digital Outputs
Between The Channels And Backplane Bus Yes; Optocoupler
Potential Separation Counter
Between The Channels And Backplane Bus Yes; Optocoupler
Isolation
Isolation Tested With 500 V
Connection Method
Required Front Connector 1X 48-Pin

Dimensions

Width 25 Mm
Height 290 Mm
Depth 210 Mm
Weight S
Weight , Approx. 650 G