This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7513-1AL00-0AB0

6ES7513-1AL00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7513-1AL00-0AB0 Siemens

6ES7513-1AL00-0AB0 Siemens - ***Spare part*** SIMATIC S7-1500, CPU 1513-1 PN, Central processing unit with Work memory 300 KB for program and 1.5 MB for data, 1st interface, PROFINET IRT with 2-port switch, 40 ns bit performance, SIMATIC Memory Card required

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7513-1AL00-0AB0
Product Description ***Spare part*** SIMATIC S7-1500, CPU 1513-1 PN, Central processing unit with Work memory 300 KB for program and 1.5 MB for data, 1st interface, PROFINET IRT with 2-port switch, 40 ns bit performance, SIMATIC Memory Card required
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
PLM Effective Date Product is cancelled since: 15.10.2015
Notes The product was replaced with the following successor product: 6ES7513-1AL02-0AB0 Compare Products This product is a Spare Part, please visit the Spares & Service section for more information If you need assistance please contact our local Siemens office

Successor information

Successor 6ES7513-1AL02-0AB0
Successor Description SIMATIC S7-1500, CPU 1513-1 PN, central processing unit with working memory 300 KB for program and 1.5 MB for data, 1. interface: PROFINET IRT with 2 port switch, 40 NS bit-performance, SIMATIC memory card necessary

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,504 Kg
Packaging Dimension 15,00 x 15,40 x 4,60
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515080121
UPC 887621139025
Commodity Code 85371091
LKZ_FDB/ CatalogID ST9-E5
Product Group 4A9H
Group Code R132
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 25.02.2013
Product class D: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
WEEE (2012/19/EU) Take-Back Obligation No
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

Isochronous Mode Yes; With Minimum Ob 6X Cycle Of 500 Μs
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V13 Sp1 Update 4
Configuration Control
Via Dataset Yes
Display
Screen Diagonal [Cm] 3.45 Cm
Control Elements
Number Of Keys 6
Mode Selector Switch 1

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Input Current
Current Consumption (Rated Value) 0.7 A
Inrush Current, Max. 1.9 A; Rated Value
I²T 0.02 A²·S
Power
Infeed Power To The Backplane Bus 10 W
Power Consumption From The Backplane Bus (Balanced) 5.5 W
Power Loss
Power Loss , Typ. 5.7 W
Memory
Simatic Memory Card Required Yes
Work Memory
Integrated (For Program) 300 Kbyte
Integrated (For Data) 1.5 Mbyte
Load Memory
Plug-In (Simatic Memory Card), Max. 32 Gbyte
Backup
Maintenance-Free Yes
Cpu Processing Times
For Bit Operations, Typ. 40 Ns
For Word Operations, Typ. 48 Ns
For Fixed Point Arithmetic, Typ. 64 Ns
For Floating Point Arithmetic, Typ. 256 Ns
Cpu-Blocks
Number Of Elements (Total) 2 000; Blocks (Ob, Fb, Fc, Db) And Udts
Db
Number Range 1 ... 60 999; Subdivided Into: Number Range That Can Be Used By The User: 1 ...
59 999, And Number Range Of Dbs Created Via Sfc 86: 60 000 ... 60 999
Size, Max. 1.5 Mbyte; For Non-Optimized Block Accesses, The Max. Size Of The Db Is 64 Kb
Fb
Number Range 0 ... 65 535
Size, Max. 300 Kbyte
Fc
Number Range 0 ... 65 535
Size, Max. 300 Kbyte
Ob
Size, Max. 300 Kbyte
Number Of Free Cycle Obs 100
Number Of Time Alarm Obs 20
Number Of Delay Alarm Obs 20
Number Of Cyclic Interrupt Obs 20
Number Of Process Alarm Obs 50
Number Of Dpv1 Alarm Obs 3
Number Of Isochronous Mode Obs 1
Number Of Technology Synchronous Alarm Obs 2
Number Of Startup Obs 100
Number Of Asynchronous Error Obs 4
Number Of Synchronous Error Obs 2
Number Of Diagnostic Alarm Obs 1
Nesting Depth
Per Priority Class 24
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
Iec Counter
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
Iec Timer
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 128 Kbyte; In Total; Available Retentive Memory For Bit Memories, Timers,
Counters, Dbs, And Technology Data (Axes): 88 Kb
Flag
Size, Max. 16 Kbyte
Number Of Clock Memories 8; 8 Clock Memory Bit, Grouped Into One Clock Memory Byte
Data Blocks
Retentivity Adjustable Yes
Retentivity Preset No
Local Data
Per Priority Class, Max. 64 Kbyte; Max. 16 Kb Per Block
Address Area
Number Of Io Modules 2 048; Max. Number Of Modules / Submodules
I/O Address Area
Inputs 32 Kbyte; All Inputs Are In The Process Image
Outputs 32 Kbyte; All Outputs Are In The Process Image
Per Integrated Io Subsystem
— Inputs (Volume) 8 Kbyte
— Outputs (Volume) 8 Kbyte
Per Cm/Cp
— Inputs (Volume) 8 Kbyte
— Outputs (Volume) 8 Kbyte
Subprocess Images
Number Of Subprocess Images, Max. 32
Hardware Configuration
Number Of Distributed Io Systems 20
Number Of Dp Masters
Via Cm 6; A Maximum Of 6 Cms/Cps (Profibus, Profinet, Ethernet) Can Be
Inserted In Total
Number Of Io Controllers
Integrated 1
Via Cm 6; A Maximum Of 6 Cms/Cps (Profibus, Profinet, Ethernet) Can Be
Inserted In Total
Rack
Modules Per Rack, Max. 32; Cpu + 31 Modules
Number Of Lines, Max. 1
Ptp Cm
Number Of Ptp Cms The Number Of Connectable Ptp Cms Is Only Limited By The Number Of Available
Slots
Time Of Day
Clock
Type Hardware Clock
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Operating Hours Counter
Number 16
Clock Synchronization
Supported Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp Yes
Interfaces
Number Of Profinet Interfaces 1
1. Interface
Interface Types
Rj 45 (Ethernet) Yes; X1
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes
Web Server Yes
Media Redundancy Yes
Profinet Io Controller
Services
— Pg/Op Communication Yes
— Isochronous Mode Yes
— Irt Yes
— Profienergy Yes
— Prioritized Startup Yes; Max. 32 Profinet Devices
— Number Of Connectable Io Devices, Max. 128; In Total, Up To 256 Distributed I/O Devices Can Be Connected Via Profibus
Or Profinet
— Of Which Io Devices With Irt, Max. 64
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
Update Time For Irt
— For Send Cycle Of 250 Μs 250 Μ S To 4 Ms; Note: In The Case Of Irt With Isochronous Mode, The Minimum
Update Time Of 625 Μs Of The Isochronous Ob Is Decisive
— For Send Cycle Of 500 Μs 500 Μs To 8 Ms
— For Send Cycle Of 1 Ms 1 Ms To 16 Ms
— For Send Cycle Of 2 Ms 2 Ms To 32 Ms
— For Send Cycle Of 4 Ms 4 Ms To 64 Ms
— With Irt And Parameterization Of "Odd" Send Cycles Update Time = Set "Odd" Send Clock (Any Multiple Of 125 Μs: 375 Μs, 625 Μs ... 3
875 Μs)
Update Time For Rt
— For Send Cycle Of 250 Μs 250 Μs To 128 Ms
— For Send Cycle Of 500 Μs 500 Μs To 256 Ms
— For Send Cycle Of 1 Ms 1 Ms To 512 Ms
— For Send Cycle Of 2 Ms 2 Ms To 512 Ms
— For Send Cycle Of 4 Ms 4 Ms To 512 Ms
Profinet Io Device
Services
— Pg/Op Communication Yes
— Isochronous Mode No
— Irt Yes
— Profienergy Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
Interface Types
Rj 45 (Ethernet)
100 Mbps Yes
Autonegotiation Yes
Autocrossing Yes
Industrial Ethernet Status Led Yes
Protocols
Profisafe No
Number Of Connections
Number Of Connections, Max. 128; Via Integrated Interfaces Of The Cpu And Connected Cps / Cms
Number Of Connections Reserved For Es/Hmi/Web 10
Number Of Connections Via Integrated Interfaces 88
Number Of S7 Routing Paths 16
Redundancy Mode
Media Redundancy
— Mrp Yes; As Mrp Redundancy Manager And/Or Mrp Client; Max. Number Of Devices
In The Ring: 50
— Switchover Time On Line Break, Typ. 200 Ms
— Number Of Stations In The Ring, Max. 50
Simatic Communication
S7 Routing Yes
S7 Communication, As Server Yes
S7 Communication, As Client Yes
User Data Per Job, Max. See Online Help (S7 Communication, User Data Size)
Open Ie Communication
Tcp/Ip Yes
— Data Length, Max. 64 Kbyte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes
— Data Length, Max. 64 Kbyte
Udp Yes
— Data Length, Max. 1 472 Byte
Dhcp No
Snmp Yes
Dcp Yes
Lldp Yes
Web Server
Http Yes; Standard And User-Defined Pages
Https Yes; Standard And User-Defined Pages
Further Protocols
Modbus Yes; Modbus Tcp
Isochronous Mode
Equidistance Yes
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 32
Program Alarms Yes
Number Of Configurable Program Messages, Max. 5 000
Number Of Simultaneously Active Program Alarms
Number Of Program Alarms 300
Number Of Alarms For System Diagnostics 100
Number Of Alarms For Motion Technology Objects 80
Test Commissioning Functions
Joint Commission (Team Engineering) Yes; Parallel Online Access Possible For Up To 5 Engineering Systems
Status Block Yes; Up To 8 Simultaneously (In Total Across All Es Clients)
Single Step No
Status/Control
Status/Control Variable Yes
Variables Inputs/Outputs, Memory Bits, Dbs, Distributed I/Os, Timers, Counters
Number Of Variables, Max.
— Of Which Status Variables, Max. 200; Per Job
— Of Which Control Variables, Max. 200; Per Job
Forcing
Forcing, Variables Peripheral Inputs/Outputs
Number Of Variables, Max. 200
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 1 000
— Of Which Powerfail-Proof 500
Traces
Number Of Configurable Traces 4; Up To 512 Kb Of Data Per Trace Are Possible
Interrupts/Diagnostics/Status Information
Diagnostics Indication Led
Run/Stop Led Yes
Error Led Yes
Maint Led Yes
Connection Display Link Tx/Rx Yes
Supported Technology Objects
Motion Control Yes
Speed-Controlled Axis
— Number Of Speed-Controlled Axes, Max. 6; Requirement: There Must Be No Other Motion Technology Objects Created;
Note: The Number Of Axes Affects The Cycle Time Of The Plc Program; Selection
Guide Via The Tia Selection Tool
Positioning Axis
— Number Of Positioning Axes, Max. 6; Requirement: There Must Be No Other Motion Technology Objects Created;
Note: The Number Of Axes Affects The Cycle Time Of The Plc Program; Selection
Guide Via The Tia Selection Tool
Synchronized Axes (Relative Gear Synchronization)
— Number Of Axes, Max. 3; Requirement: There Must Be No Other Motion Technology Objects Created;
Note: The Number Of Axes Affects The Cycle Time Of The Plc Program; Selection
Guide Via The Tia Selection Tool
External Encoders
— Number Of External Encoders, Max. 6; Requirement: There Must Be No Other Motion Technology Objects Created;
Note: The Number Of Axes Affects The Cycle Time Of The Plc Program; Selection
Guide Via The Tia Selection Tool
Control Ler
Pid_Compact Yes; Universal Pid Controller With Integrated Optimization
Pid_3Step Yes; Pid Controller With Integrated Optimization For Valves
Pid-Temp Yes; Pid Controller With Integrated Optimization For Temperature
Counting And Measuring
High-Speed Counter Yes

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 60 °C; Display: 50 °C, At An Operating Temperature Of Typically 50 °C, The
Display Is Switched Off
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 40 °C; Display: 40 °C, At An Operating Temperature Of Typically 40 °C, The
Display Is Switched Off
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes
— Fbd Yes
— Stl Yes
— Scl Yes
— Graph Yes
Know-How Protection
User Program Protection/Password Protection Yes
Copy Protection Yes
Block Protection Yes
Access Protection
Password For Display Yes
Protection Level: Write Protection Yes
Protection Level: Read/Write Protection Yes
Protection Level: Complete Protection Yes
Programming / Cycle Time Monitoring / Header
Lower Limit Adjustable Minimum Cycle Time
Upper Limit Adjustable Maximum Cycle Time

Dimensions

Width 35 Mm
Height 147 Mm
Depth 129 Mm
Weight S
Weight , Approx. 430 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible