This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7517-3FP00-0AB0

6ES7517-3FP00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7517-3FP00-0AB0 Siemens

6ES7517-3FP00-0AB0 Siemens - CPU 1517F-3 PN/DP, 3MB PROG., 8MB DATA

Extended Description for 6ES7517-3FP00-0AB0 Siemens

6ES7517-3FP00-0AB0 Siemens - SIMATIC S7-1500F, CPU 1517F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 3 MB FOR PROGRAM AND 8 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE, ETHERNET, 3. INTERFACE, PROFIBUS, 2 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7517-3FP00-0AB0
Product Description SIMATIC S7-1500F, CPU 1517F-3 PN/DP, central processing unit with work memory 3 MB for program and 8 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFIBUS, 2 ns bit performance, SIMATIC Memory Card required
Product family CPU 1517F-3 PN/DP
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 2,104 Kg
Packaging Dimension 19,80 x 22,30 x 15,90
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623403944
UPC 887621836221
Commodity Code 85371091
LKZ_FDB/ CatalogID ST73
Product Group 4526
Group Code R152
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 21.07.2014
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Isochronous Mode Yes; Distributed And Central; With Minimum Ob 6X Cycle Of 250 Μs (Distributed)
And 1 Ms (Central)
Syslog Yes
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V19 (Fw V3.1); V13 Update 3 (Fw V1.6) Or Higher
Configuration Control
Via Dataset Yes
Display
Screen Diagonal [Cm] 6.1 Cm
Control Elements
Number Of Keys 6
Mode Selector Switch 1

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Mains Buffering
Mains/Voltage Failure Stored Energy Time 5 Ms
Repeat Rate, Min. 1/S
Input Current
Current Consumption (Rated Value) 1.55 A
Current Consumption, Max. 1.9 A
Inrush Current, Max. 1.9 A; Rated Value
I²T 0.4 A²·S
Power
Infeed Power To The Backplane Bus 12 W
Power Consumption From The Backplane Bus (Balanced) 30 W
Power Loss
Power Loss , Typ. 24 W
Memory
Number Of Slots For Simatic Memory Card 1
Simatic Memory Card Required Yes
Work Memory
Integrated (For Program) 3 Mbyte
Integrated (For Data) 8 Mbyte
Load Memory
Plug-In (Simatic Memory Card), Max. 32 Gbyte
Backup
Maintenance-Free Yes
Cpu Processing Times
For Bit Operations, Typ. 2 Ns
For Word Operations, Typ. 3 Ns
For Fixed Point Arithmetic, Typ. 3 Ns
For Floating Point Arithmetic, Typ. 12 Ns
Cpu-Blocks
Number Of Elements (Total) 12 000; Blocks (Ob, Fb, Fc, Db) And Udts
Db
Number Range 1 ... 60 999; Subdivided Into: Number Range That Can Be Used By The User: 1 ...
59 999, And Number Range Of Dbs Created Via Sfc 86: 60 000 ... 60 999
Size, Max. 8 Mbyte; For Dbs With Absolute Addressing, The Max. Size Is 64 Kb
Fb
Number Range 0 ... 65 535
Size, Max. 1 Mbyte
Fc
Number Range 0 ... 65 535
Size, Max. 1 Mbyte
Ob
Size, Max. 1 Mbyte
Number Of Free Cycle Obs 100
Number Of Time Alarm Obs 20
Number Of Delay Alarm Obs 20
Number Of Cyclic Interrupt Obs 20; With Minimum Ob 3X Cycle Of 100 Μs
Number Of Process Alarm Obs 50
Number Of Dpv1 Alarm Obs 3
Number Of Isochronous Mode Obs 3
Number Of Technology Synchronous Alarm Obs 2
Number Of Startup Obs 100
Number Of Asynchronous Error Obs 4
Number Of Synchronous Error Obs 2
Number Of Diagnostic Alarm Obs 1
Nesting Depth
Per Priority Class 24; Up To 8 Possible For F-Blocks
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
Iec Counter
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
Iec Timer
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 768 Kbyte; In Total; Available Retentive Memory For Bit Memories, Timers,
Counters, Dbs, And Technology Data (Axes): 700 Kb
Extended Retentive Data Area (Incl. Timers, Counters, Flags), Max. 8 Mbyte; When Using Ps 6 0W 24/48/60 V Dc Hf
Flag
Size, Max. 16 Kbyte
Number Of Clock Memories 8; 8 Clock Memory Bit, Grouped Into One Clock Memory Byte
Data Blocks
Retentivity Adjustable Yes
Retentivity Preset No
Local Data
Per Priority Class, Max. 64 Kbyte; Max. 16 Kb Per Block
Address Area
Number Of Io Modules 16 384; Max. Number Of Modules / Submodules
I/O Address Area
Inputs 32 Kbyte; All Inputs Are In The Process Image
Outputs 32 Kbyte; All Outputs Are In The Process Image
Per Integrated Io Subsystem
— Inputs (Volume) 32 Kbyte; Max. 32 Kb Via X1; Max. 8 Kb Via X2 Or X3
— Outputs (Volume) 32 Kbyte; Max. 32 Kb Via X1; Max. 8 Kb Via X2 Or X3
Per Cm/Cp
— Inputs (Volume) 8 Kbyte
— Outputs (Volume) 8 Kbyte
Subprocess Images
Number Of Subprocess Images, Max. 32
Hardware Configuration
Number Of Distributed Io Systems 64; A Distributed I/O System Is Characterized Not Only By The Integration Of
Distributed I/O Via Profinet Or Profibus Communication Modules, But Also
By The Connection Of I/O Via As-I Master Modules Or Links (E.G. Ie/Pb-Link)
Number Of Dp Masters
Integrated 1
Via Cm 8; A Maximum Of 8 Cms/Cps (Profibus, Profinet, Ethernet) Can Be
Inserted In Total
Number Of Io Controllers
Integrated 2
Via Cm 8; A Maximum Of 8 Cms/Cps (Profibus, Profinet, Ethernet) Can Be
Inserted In Total
Rack
Modules Per Rack, Max. 32; Cpu + 31 Modules
Number Of Lines, Max. 1
Ptp Cm
Number Of Ptp Cms The Number Of Connectable Ptp Cms Is Only Limited By The Number Of Available
Slots
Time Of Day
Clock
Type Hardware Clock
Backup Time 6 Wk; At 40 °C Ambient Temperature, Typically
Deviation Per Day, Max. 10 S; Typ.: 2 S
Operating Hours Counter
Number 16
Clock Synchronization
Supported Yes
To Dp, Master Yes
On Dp, Device Yes
In As, Master Yes
In As, Device Yes
On Ethernet Via Ntp Yes
Interfaces
Number Of Profinet Interfaces 2
Number Of Profibus Interfaces 1
1. Interface
Interface Types
Rj 45 (Ethernet) Yes; X1
Number Of Ports 2
Integrated Switch Yes
Protocols
Ip Protocol Yes; Ipv4
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes; Optionally Also Encrypted
Web Server Yes
Media Redundancy Yes
Profinet Io Controller
Services
— Isochronous Mode Yes
— Direct Data Exchange Yes; Requirement: Irt And Isochronous Mode (Mrpd Optional)
— Irt Yes
— Profienergy Yes; Per User Program
— Prioritized Startup Yes; Max. 32 Profinet Devices
— Number Of Connectable Io Devices, Max. 512; In Total, Up To 1 000 Distributed I/O Devices Can Be Connected Via As-I,
Profibus Or Profinet
— Of Which Io Devices With Irt, Max. 64
— Number Of Connectable Io Devices For Rt, Max. 512
— Of Which In Line, Max. 512
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8; In Total Across All Interfaces
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
— Profinet Security Class 1
Update Time For Irt
— For Send Cycle Of 250 Μs 250 Μs To 4 Ms
— For Send Cycle Of 500 Μs 500 Μs To 8 Ms
— For Send Cycle Of 1 Ms 1 Ms To 16 Ms
— For Send Cycle Of 2 Ms 2 Ms To 32 Ms
— For Send Cycle Of 4 Ms 4 Ms To 64 Ms
— With Irt And Parameterization Of "Odd" Send Cycles Update Time = Set "Odd" Send Clock (Any Multiple Of 125 Μs: 375 Μs, 625 Μs ... 3
875 Μs)
Update Time For Rt
— For Send Cycle Of 250 Μs 250 Μs To 128 Ms
— For Send Cycle Of 500 Μs 500 Μs To 256 Ms
— For Send Cycle Of 1 Ms 1 Ms To 512 Ms
— For Send Cycle Of 2 Ms 2 Ms To 512 Ms
— For Send Cycle Of 4 Ms 4 Ms To 512 Ms
Profinet Io Device
Services
— Isochronous Mode No
— Irt Yes
— Profienergy Yes; Per User Program
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
— Activation/Deactivation Of I-Devices Yes; Per User Program
— Asset Management Record Yes; Per User Program
— Profinet Security Class Snmp Configuration And Dcp Read Only
2. Interface
Interface Types
Rj 45 (Ethernet) Yes; X2
Number Of Ports 1
Integrated Switch No
Protocols
Ip Protocol Yes; Ipv4
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes; Optionally Also Encrypted
Web Server Yes
Media Redundancy No
Profinet Io Controller
Services
— Isochronous Mode No
— Direct Data Exchange No
— Irt No
— Profienergy Yes; Per User Program
— Prioritized Startup No
— Number Of Connectable Io Devices, Max. 128; In Total, Up To 1 000 Distributed I/O Devices Can Be Connected Via As-I,
Profibus Or Profinet
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8; In Total Across All Interfaces
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
— Profinet Security Class 1
Update Time For Rt
— For Send Cycle Of 1 Ms 1 Ms To 512 Ms
Profinet Io Device
Services
— Isochronous Mode No
— Irt No
— Profienergy Yes; Per User Program
— Prioritized Startup No
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
— Activation/Deactivation Of I-Devices Yes; Per User Program
— Asset Management Record Yes; Per User Program
— Profinet Security Class Snmp Configuration And Dcp Read Only
3. Interface
Interface Types
Rs 485 Yes; X3
Number Of Ports 1
Protocols
Profibus Dp Master Yes
Profibus Dp Device No
Simatic Communication Yes
Profibus Dp Master
Number Of Connections, Max. 48; For The Integrated Profibus Dp Interface
Max. Number Of Dp Devices 125; In Total, Up To 1 000 Distributed I/O Devices Can Be Connected Via As-I,
Profibus Or Profinet
Services
— Equidistance Yes
— Isochronous Mode Yes
— Activation/Deactivation Of Dp Devices Yes
Interface Types
Rj 45 (Ethernet)
100 Mbps Yes
Autonegotiation Yes
Autocrossing Yes
Industrial Ethernet Status Led Yes
Rs 485
Transmission Rate, Max. 12 Mbit/S
Protocols
Profisafe Yes; V2.4 / V2.6
Number Of Connections
Number Of Connections, Max. 320; Via Integrated Interfaces Of The Cpu And Connected Cps / Cms
Number Of Connections Reserved For Es/Hmi/Web 10
Number Of Connections Via Integrated Interfaces 288
Number Of S7 Routing Paths 64; In Total, Only 16 S7-Routing Connections Are Supported Via Profibus
Redundancy Mode
H-Sync Forwarding Yes
Media Redundancy
— Media Redundancy Only Via 1St Interface (X1)
— Mrp Yes; Mrp Automanager According To Iec 62439-2 Edition 2.0, Mrp Manager;
Mrp Client
— Mrp Interconnection, Supported Yes; As Mrp Ring Node According To Iec 62439-2 Edition 3.0
— Mrpd Yes; Requirement: Irt
— Switchover Time On Line Break, Typ. 200 Ms; For Mrp, Bumpless For Mrpd
— Number Of Stations In The Ring, Max. 50
Simatic Communication
Pg/Op Communication Yes; Encryption With Tls V1.3 Pre-Selected
S7 Routing Yes
Data Record Routing Yes
S7 Communication, As Server Yes
S7 Communication, As Client Yes
User Data Per Job, Max. See Online Help (S7 Communication, User Data Size)
Open Ie Communication
Tcp/Ip Yes
— Data Length, Max. 64 Kbyte
— Several Passive Connections Per Port, Supported Yes
Iso-On-Tcp (Rfc1006) Yes
— Data Length, Max. 64 Kbyte
Udp Yes
— Data Length, Max. 2 Kbyte; 1 472 Bytes For Udp Broadcast
— Udp Multicast Yes; 128 Multicast Circuits (Of Which Max. 5 Via X1)
Dhcp Yes
Dns Yes
Snmp Yes
Dcp Yes
Lldp Yes
Encryption Yes; Optional
Web Server
Http Yes; Standard And User Pages
Https Yes; Standard And User Pages
Web Api
— Number Of Sessions, Max. 200
— Number Of Simultaneous Http Calls, Max. 4
— Http Request Body, Max. 131 072 Byte
Opc Ua
Runtime License Required Yes; "Large" License Required
Opc Ua Client Yes; Data Access (Registered Read/Write), Method Call
— Application Authentication Yes
— Security Policies Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User Authentication "Anonymous" Or By User Name & Password
— Number Of Connections, Max. 40
— Number Of Nodes Of The Client Interfaces,
Recommended Max.5 000
— Number Of Elements For One Call Of
Opc_Ua_Nodegethandlelist/Opc_Ua_Readlist/Opc_Ua_Writelist,
Max.300
— Number Of Elements For One Call Of
Opc_Ua_Namespacegetindexlist, Max.20
— Number Of Elements For One Call Of
Opc_Ua_Methodgethandlelist, Max.100
— Number Of Simultaneous Calls Of The Client
Instructions For Session Management, Per Connection,
Max.1
— Number Of Simultaneous Calls Of The Client
Instructions For Data Access, Per Connection, Max.5
— Number Of Registerable Nodes, Max. 5 000
— Number Of Registerable Method Calls Of
Opc_Ua_Methodcall, Max.100
— Number Of Inputs/Outputs When Calling
Opc_Ua_Methodcall, Max.20
Opc Ua Server Yes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition
(A&C), Custom Address Space
— Application Authentication Yes
— Security Policies Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256, Aes128Sha256Rsaoaep, Aes256Sha256Rsapss
— User Authentication "Anonymous" Or By User Name & Password
— Gds Support (Certificate Management) Yes
— Number Of Sessions, Max. 64
— Number Of Accessible Variables, Max. 200 000
— Number Of Registerable Nodes, Max. 50 000
— Number Of Subscriptions Per Session, Max. 50
— Sampling Interval, Min. 10 Ms
— Publishing Interval, Min. 10 Ms
— Number Of Server Methods, Max. 100
— Number Of Inputs/Outputs Per Server Method, Max. 20
— Number Of Monitored Items, Recommended Max. 10 000; For 1 S Sampling Interval And 1 S Send Interval
— Number Of Server Interfaces, Max. 10 Of Each "Server Interfaces" / "Companion Specification" Type And 20 Of The
Type "Reference Namespace"
— Number Of Nodes For User-Defined Server Interfaces,
Max.30 000
Alarms And Conditions Yes
— Number Of Program Alarms 400
— Number Of Alarms For System Diagnostics 200
Further Protocols
Modbus Yes; Modbus Tcp
Isochronous Mode
Equidistance Yes
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 64
Number Of Subscriptions, Max. 750
Number Of Tags/Attributes For Subscriptions, Max. 20 000
Program Alarms Yes
Number Of Configurable Program Messages, Max. 10 000; Program Messages Are Generated By The "Program_Alarm" Block,
Prodiag Or Graph
Number Of Loadable Program Messages In Run, Max. 10 000
Number Of Simultaneously Active Program Alarms
Number Of Program Alarms 2 000
Number Of Alarms For System Diagnostics 1 000
Number Of Alarms For Motion Technology Objects 480
Test Commissioning Functions
Joint Commission (Team Engineering) Yes; Parallel Online Access Possible For Up To 10 Engineering Systems
Status Block Yes; Up To 16 Simultaneously (In Total Across All Es Clients)
Single Step No
Number Of Breakpoints 20
Profiling No
Status/Control
Status/Control Variable Yes; Without Fail-Safe
Variables Inputs/Outputs, Bit Memories, Dbs, Peripheral I/Os (Without Fail-Safe), Times,
Counters
Number Of Variables, Max.
— Of Which Status Variables, Max. 200; Per Job
— Of Which Control Variables, Max. 200; Per Job
Forcing
Forcing Yes; Without Fail-Safe
Forcing, Variables Peripheral Inputs/Outputs (Without Fail-Safe)
Number Of Variables, Max. 200
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 3 200
— Of Which Powerfail-Proof 1 000
Traces
Number Of Configurable Traces 8
Memory Size Per Trace, Max. 512 Kbyte
Interrupts/Diagnostics/Status Information
Diagnostics Indication Led
Run/Stop Led Yes
Error Led Yes
Maint Led Yes
Connection Display Link Tx/Rx Yes
Supported Technology Objects
Motion Control Yes; Note: The Number Of Technology Objects Affects The Cycle Time Of The Plc
Program; Selection Guide Via The Tia Selection Tool
Number Of Available Motion Control Resources For
Technology Objects10 240
Required Motion Control Resources
— Per Speed-Controlled Axis 40
— Per Positioning Axis 80
— Per Synchronous Axis 160
— Per External Encoder 80
— Per Output Cam 20
— Per Cam Track 160
— Per Probe 40
Positioning Axis
— Number Of Positioning Axes At Motion Control Cycle
Of 4 Ms (Typical Value)70
— Number Of Positioning Axes At Motion Control Cycle
Of 8 Ms (Typical Value)128
Control Ler
Pid_Compact Yes; Universal Pid Controller With Integrated Optimization
Pid_3Step Yes; Pid Controller With Integrated Optimization For Valves
Pid-Temp Yes; Pid Controller With Integrated Optimization For Temperature
Counting And Measuring
High-Speed Counter Yes
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 570 Kg
— Global Warming Potential, (During Production) [Co2
Eq]96.9 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]483 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-9.97 Kg
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 3
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 2.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 1.00E-09

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 60 °C; Display: 50 °C, At An Operating Temperature Of Typically 50 °C, The
Display Is Switched Off
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 40 °C; Display: 40 °C, At An Operating Temperature Of Typically 40 °C, The
Display Is Switched Off
Ambient Temperature During Storage/Transportation
Min. -40 °C
Max. 70 °C
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M; Restrictions For Installation Altitudes > 2 000 M, See Manual
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes; Incl. Failsafe
— Fbd Yes; Incl. Failsafe
— Stl Yes
— Scl Yes
— Cfc Yes; Either Cfc Or Failsafe Functionality
— Graph Yes
Know-How Protection
User Program Protection/Password Protection Yes
Copy Protection Yes
Block Protection Yes
Access Protection
Protection Of Confidential Configuration Data Yes
Password For Display Yes
Protection Level: Write Protection Yes
Protection Level: Read/Write Protection Yes
Protection Level: Write Protection For Failsafe Yes
Protection Level: Complete Protection Yes
User Administration Yes; Device-Wide
Programming / Cycle Time Monitoring / Header
Lower Limit Adjustable Minimum Cycle Time
Upper Limit Adjustable Maximum Cycle Time

Dimensions

Width 175 Mm
Height 147 Mm
Depth 129 Mm
Weight S
Weight , Approx. 1 929 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible