This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7531-7NF00-0AB0

6ES7531-7NF00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7531-7NF00-0AB0 Siemens

6ES7531-7NF00-0AB0 Siemens - S7-1500. AI 8XU/I HF

Extended Description for 6ES7531-7NF00-0AB0 Siemens

6ES7531-7NF00-0AB0 Siemens - SIMATIC s7-1500. analog input module ai 8 x u/i hf. 16 bits of resolution. accurACy 0.1%. 8 channels in groups of 1 common mode voltage 30V AC/60V DC. diagnosis. processalarms incl. infeed element. shield clamp and shield terminal

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£684.53 Exc. VAT
£821.44 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7531-7NF00-0AB0
Product Description SIMATIC S7-1500 analog input module AI 8xU/I HF, up to 24 bit resolution, accuracy 0.1%, 8 channels in groups of 1; common mode voltage: 30 V AC/60 V DC, Diagnostics; Hardware interrupts Measured values ​​scalable, measuring range adjustment, Calibrate in RUN; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately
Product family SM 531 analog input modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,402 Kg
Packaging Dimension 16,10 x 19,20 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623406549
UPC 804766242991
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 4501
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.03.2016
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Isochronous Mode No
Prioritized Startup Yes
Measuring Range Scalable No
Scalable Measured Values Yes
Adjustment Of Measuring Range Yes
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V14 / -
Step 7 Configurable/Integrated From Version V5.5 Sp3 / -
Profibus From Gsd Version/Gsd Revision V1.0 / V5.1
Profinet From Gsd Version/Gsd Revision V2.3 / -
Operating Mode
Oversampling No
Msi Yes
Cir - Configuration In Run
Reparameterization Possible In Run Yes
Calibration Possible In Run Yes

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Input Current
Current Consumption, Max. 50 Ma; With 24 V Dc Supply
Power
Power Available From The Backplane Bus 0.85 W
Power Loss
Power Loss , Typ. 1.9 W

Analog Inputs

Number Of Analog Inputs 8
For Current Measurement 8
For Voltage Measurement 8
Permissible Input Voltage For Voltage Input (Destruction Limit),
Max.28.8 V
Permissible Input Current For Current Input (Destruction Limit),
Max.40 Ma
Input Ranges (Rated Values), Voltages
0 To +5 V No
0 To +10 V No
1 V To 5 V Yes
— Input Resistance (1 V To 5 V) 100 K Ω
-10 V To +10 V Yes
— Input Resistance (-10 V To +10 V) 100 K Ω
-2.5 V To +2.5 V Yes
— Input Resistance (-2.5 V To +2.5 V) 100 K Ω
-25 Mv To +25 Mv No
-250 Mv To +250 Mv No
-5 V To +5 V Yes
— Input Resistance (-5 V To +5 V) 100 K Ω
-50 Mv To +50 Mv No
-500 Mv To +500 Mv No
-80 Mv To +80 Mv No
Input Ranges (Rated Values), Currents
0 To 20 Ma Yes
— Input Resistance (0 To 20 Ma) 25 Ω; Plus Approx. 42 Ohms For Overvoltage Protection By Ptc
-20 Ma To +20 Ma Yes
— Input Resistance (-20 Ma To +20 Ma) 25 Ω; Plus Approx. 42 Ohms For Overvoltage Protection By Ptc
4 Ma To 20 Ma Yes
— Input Resistance (4 Ma To 20 Ma) 25 Ω; Plus Approx. 42 Ohms For Overvoltage Protection By Ptc
Input Ranges (Rated Values), Thermocouples
Type B No
Type C No
Type E No
Type J No
Type K No
Type L No
Type N No
Type R No
Type S No
Type T No
Type Txk/Txk(L) To Gost No
Input Ranges (Rated Values), Resistance Thermometer
Cu 10 No
Cu 10 According To Gost No
Cu 50 No
Cu 50 According To Gost No
Cu 100 No
Cu 100 According To Gost No
Ni 10 No
Ni 10 According To Gost No
Ni 100 No
Ni 100 According To Gost No
Ni 1000 No
Ni 1000 According To Gost No
Lg-Ni 1000 No
Ni 120 No
Ni 120 According To Gost No
Ni 200 No
Ni 200 According To Gost No
Ni 500 No
Ni 500 According To Gost No
Pt 10 No
Pt 10 According To Gost No
Pt 50 No
Pt 50 According To Gost No
Pt 100 No
Pt 100 According To Gost No
Pt 1000 No
Pt 1000 According To Gost No
Pt 200 No
Pt 200 According To Gost No
Pt 500 No
Pt 500 According To Gost No
Input Ranges (Rated Values), Resistors
0 To 150 Ohms No
0 To 300 Ohms No
0 To 600 Ohms No
0 To 3000 Ohms No
0 To 6000 Ohms No
Ptc No
Cable Length
Shielded, Max. 800 M
Analog Value Generation For The Inputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 24 Bit; When Using The Function "Scaling Of The Measured Values" Or "Measuring
Range Adaptation" (32 Bit Real Format); 16 Bit When Using The S7 Format (16 Bit
Integer)
Integration Time, Parameterizable Yes
Integration Time (Ms) Fast Mode: 2.5 / 16.67 / 20 / 100 Ms, Standard Mode: 7.5 / 50 / 60 / 300 Ms
Basic Conversion Time, Including Integration Time (Ms) Fast Mode: 4 / 18 / 22 / 102 Ms; Standard Mode: 9 / 52 / 62 / 302 Ms
Interference Voltage Suppression For Interference
Frequency F1 In Hz400 / 60 / 50 / 10 Hz
Basic Execution Time Of The Module (All Channels
Released)Corresponds To The Channel With The Highest Basic Conversion Time
Smoothing Of Measured Values
Parameterizable Yes
Step: None Yes
Step: Low Yes
Step: Medium Yes
Step: High Yes
Encoder
Connection Of Signal Encoders
For Voltage Measurement Yes
For Current Measurement As 2-Wire Transducer Yes; With External Transmitter Supply
For Current Measurement As 4-Wire Transducer Yes
For Resistance Measurement With Two-Wire Connection No
For Resistance Measurement With Three-Wire Connection No
For Resistance Measurement With Four-Wire Connection No
Errors/Accuracies
Linearity Error (Relative To Input Range), (+/-) 0.02 %
Temperature Error (Relative To Input Range), (+/-) 0.005 %/K
Crosstalk Between The Inputs, Max. -80 Db
Repeat Accuracy In Steady State At 25 °C (Relative To Input
Range), (+/-)0.02 %
Note Regarding Accuracy At Temperatures Below 0 °C, The Figures For Operating Error And Temperature
Error Are Doubled
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Input Range, (+/-) 0.1 %
Current, Relative To Input Range, (+/-) 0.1 %
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Input Range, (+/-) 0.05 %
Current, Relative To Input Range, (+/-) 0.05 %
Interference Voltage Suppression For F = N X (F1 +/- 1 %), F1 = Interference Frequency
Series Mode Interference (Peak Value Of Interference <
Rated Value Of Input Range), Min.80 Db; In The Standard Operating Mode, 40 Db In The Fast Operating Mode
Common Mode Voltage, Max. 60 V Dc/30 V Ac
Common Mode Interference, Min. 80 Db
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Limit Value Alarm Yes; Two Upper And Two Lower Limit Values In Each Case
Diagnoses
Monitoring The Supply Voltage Yes
Wire-Break Yes; Only For 1 ... 5 V And 4 ... 20 Ma
Overflow/Underflow Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Module Diagnostics Yes; Red Led
Potential Separation
Potential Separation Channels
Between The Channels Yes
Between The Channels, In Groups Of 1
Between The Channels And Backplane Bus Yes
Between The Channels And The Power Supply Of The
Electronicsyes
Permissible Potential Difference
Between Different Circuits 60 V Dc/30 V Ac; Insulation Rated For 120 V Ac Basic Insulation: Between The
Channels And The Supply Voltage L+; Between The Channels And The Backplane
Bus; Between The Channels
Isolation
Isolation Tested With 2 000 V Dc Between The Channels And The Supply Voltage L+; 2 000 V Dc
Between The Channels And The Backplane Bus; 2 000 V Dc Between The
Channels; 707 V Dc (Type Test) Between The Supply Voltage L+ And The
Backplane Bus
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 38.6 Kg
— Global Warming Potential, (During Production) [Co2
Eq]14.4 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]24.6 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.44 Kg
Product Functions / Security / Header
Signed Firmware Update No
Data Integrity No

Ambient Temperature During Operation

Horizontal Installation, Min. -30 °C; From Fs02
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. -30 °C; From Fs02
Vertical Installation, Max. 40 °C

Dimensions

Width 35 Mm
Height 147 Mm
Depth 129 Mm
Weight S
Weight , Approx. 280 G

Documentation