This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7532-5ND00-0AB0

6ES7532-5ND00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7532-5ND00-0AB0 Siemens

6ES7532-5ND00-0AB0 Siemens - S7-1500. AQ 4XU/I HF

Extended Description for 6ES7532-5ND00-0AB0 Siemens

6ES7532-5ND00-0AB0 Siemens - SIMATIC s7-1500. analog output module aq 4 x u/i hf. 16 bits of resolution. accurACy 0.1%. 4 channels in groups of 1 common mode voltage 30V AC/60V DC. diagnosis. substitute value incl. infeed element. shield clamp and shield terminal

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£592.45 Exc. VAT
£710.94 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7532-5ND00-0AB0
Product Description SIMATIC S7-1500, analog output module AQ 4xU/I HF, 16-bit resolution accuracy 0.1%, 4 channels in groups of 1, common mode voltage: 30 V AC/60 V DC, diagnostics; substitute value, isochronous mode; the module supports the safety-oriented shutdown of load groups up to SIL2 according to EN IEC 62061:2021 and Category 3 / PL d according to EN ISO 13849-1:2015. delivery including infeed element, shielding bracket and shield terminal: front connector (screw terminals or push-in) to be ordered separately
Product family SM 532 analog output modules
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,412 Kg
Packaging Dimension 16,10 x 19,30 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623406556
UPC 804766259432
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 4501
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.03.2016
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2,2',6,6'-tetrabromo... CAS-No. 79-94-7 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Isochronous Mode Yes
Prioritized Startup Yes
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V14 / -
Step 7 Configurable/Integrated From Version V5.5 Sp3 / -
Profibus From Gsd Version/Gsd Revision V1.0 / V5.1
Profinet From Gsd Version/Gsd Revision V2.3 / -
Operating Mode
Oversampling No
Mso Yes
Cir - Configuration In Run
Reparameterization Possible In Run Yes
Calibration Possible In Run Yes

Supply Voltage

Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 20.4 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Input Current
Current Consumption, Max. 160 Ma; With 24 V Dc Supply
Power
Power Available From The Backplane Bus 0.95 W
Power Loss
Power Loss , Typ. 5 W
Analog Outputs
Number Of Analog Outputs 4
Voltage Output, Short-Circuit Protection Yes
Voltage Output, Short-Circuit Current, Max. 24 Ma
Current Output, No-Load Voltage, Max. 22 V
Cycle Time (All Channels), Min. 125 Μs; Independent Of Number Of Activated Channels
Output Ranges, Voltage
0 To 10 V Yes
1 V To 5 V Yes
-5 V To +5 V No
-10 V To +10 V Yes
Output Ranges, Current
0 To 20 Ma Yes
-20 Ma To +20 Ma Yes
4 Ma To 20 Ma Yes
Connection Of Actuators
For Voltage Output Two-Wire Connection Yes
For Voltage Output Four-Wire Connection Yes
For Current Output Two-Wire Connection Yes
Load Impedance (In Rated Range Of Output)
With Voltage Outputs, Min. 1 Kω; 0.5 Kohm At 1 To 5 V
With Voltage Outputs, Capacitive Load, Max. 1 Μf
With Current Outputs, Max. 750 Ω
With Current Outputs, Inductive Load, Max. 10 Mh
Cable Length
Shielded, Max. 800 M; For Current, 200 M For Voltage
Analog Value Generation For The Outputs
Integration And Conversion Time/Resolution Per Channel
Resolution With Overrange (Bit Including Sign), Max. 16 Bit
Conversion Time (Per Channel) 125 Μs; Independent Of Number Of Activated Channels
Settling Time
For Resistive Load 0.2 Ms; See Additional Description In The Manual
For Capacitive Load 1.8 Ms; See Additional Description In The Manual
For Inductive Load 2 Ms; See Additional Description In The Manual
Errors/Accuracies
Output Ripple (Relative To Output Range, Bandwidth 0 To 50 Khz),
(+/-)0.02 %
Linearity Error (Relative To Output Range), (+/-) 0.015 %
Temperature Error (Relative To Output Range), (+/-) 0.002 %/K
Crosstalk Between The Outputs, Max. -100 Db
Repeat Accuracy In Steady State At 25 °C (Relative To Output
Range), (+/-)0.005 %
Operation Al Error Limit In Overall Temperature Range
Voltage, Relative To Output Range, (+/-) ±10 V; 0 V To 10 V: ±0.12%; 1 V To 5 V: ±0.1%
Current, Relative To Output Range, (+/-) ±20 Ma; 0 Ma To 20 Ma: ±0.2%; 4 Ma To 20 Ma: ±0.12%
Basic Error Limit (Operational Limit At 25 °C)
Voltage, Relative To Output Range, (+/-) 0.06 %
Current, Relative To Output Range, (+/-) 0.1 %
Isochronous Mode
Execution And Activation Time (Tco), Min. 100 Μs
Bus Cycle Time (Tdp), Min. 250 Μs
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Substitute Values Connectable Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Monitoring The Supply Voltage Yes
Wire-Break Yes; Only For Output Type "Current"
Short-Circuit Yes; Only For Output Type "Voltage"
Overflow/Underflow Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
For Module Diagnostics Yes; Red Led
Potential Separation
Potential Separation Channels
Between The Channels Yes
Between The Channels, In Groups Of 1
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ Yes
Permissible Potential Difference
Between Different Circuits 60 V Dc/30 V Ac; Insulation Rated For 120 V Ac Basic Insulation: Between The
Channels And The Supply Voltage L+; Between The Channels And The Backplane
Bus; Between The Channels
Isolation
Isolation Tested With 2 000 V Dc Between The Channels And The Supply Voltage L+; 2 000 V Dc
Between The Channels And The Backplane Bus; 2 000 V Dc Between The
Channels; 707 V Dc (Type Test) Between The Supply Voltage L+ And The
Backplane Bus
Standards, Approvals, Certificates
Ecological Footprint
Environmental Product Declaration Yes
Global Warming Potential
— Global Warming Potential, (Total) [Co2 Eq] 37.6 Kg
— Global Warming Potential, (During Production) [Co2
Eq]11.1 Kg
— Global Warming Potential, (During Operation) [Co2
Eq]26.8 Kg
— Global Warming Potential, (After End Of Life Cycle)
[Co2 Eq]-0.364 Kg
Product Functions / Security / Header
Signed Firmware Update No
Data Integrity No

Ambient Temperature During Operation

Horizontal Installation, Min. -25 °C; From Fs02
Horizontal Installation, Max. 60 °C
Vertical Installation, Min. -25 °C; From Fs02
Vertical Installation, Max. 40 °C

Dimensions

Width 35 Mm
Height 147 Mm
Depth 129 Mm
Weight S
Weight , Approx. 300 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible