This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7553-1AA00-0AB0

6ES7553-1AA00-0AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7553-1AA00-0AB0 Siemens

6ES7553-1AA00-0AB0 Siemens - S7-1500. TM PTO4

Extended Description for 6ES7553-1AA00-0AB0 Siemens

6ES7553-1AA00-0AB0 Siemens - SIMATIC S7-1500. TM PTO 4 Interface module for stepper drives 4 channels Pulse Train Output PTO: 24 V. 2 DI. 1 DQ 24VDC per channel

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6ES7553-1AA00-0AB0
Product Description SIMATIC S7-1500, TM PTO 4 interface module for stepper drives 4 channels pulse train output PTO: 24 V, RS-422, 5 V, 2 DI, 1 DQ 24VDC per channel
Product family TM PTO 4 interface module for PTO (Pulse Train Output)
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,411 Kg
Packaging Dimension 16,10 x 19,50 x 5,00
Package size unit of measure CM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047623406938
UPC 804766370939
Commodity Code 85389091
LKZ_FDB/ CatalogID ST73
Product Group 4502
Group Code R151
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 31.01.2017
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Isochronous Mode Yes
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version Step 7 V14 Or Higher
Step 7 Configurable/Integrated From Version V5.5 Sp3 With Gsd File / -
Profinet From Gsd Version/Gsd Revision Gsdml V2.32
Installation Type/Mounting
Rail Mounting Yes; S7-1500 Mounting Rail

Supply Voltage

Load Voltage L+
Rated Value (Dc) 24 V
Permissible Range, Lower Limit (Dc) 19.2 V
Permissible Range, Upper Limit (Dc) 28.8 V
Reverse Polarity Protection Yes
Input Current
Current Consumption, Max. 70 Ma; Without Load
Power
Power Available From The Backplane Bus 1.3 W
Power Loss
Power Loss , Typ. 4 W
Address Area
Address Space Per Module
Inputs 18 Byte; Per Channel
Outputs 10 Byte; Per Channel
Digital Inputs
Number Of Digital Inputs 12; 3 Per Channel, Of Which 1 Diq
Digital Inputs, Parameterizable Yes
Input Characteristic Curve In Accordance With Iec 61131, Type 3 Yes
Digital Input Functions, Parameterizable
Synchronization Yes
Probe Yes
Drive Ready Yes
Input Voltage
Type Of Input Voltage Dc
Rated Value (Dc) 24 V
For Signal "0" -5 ... +5 V
For Signal "1" +11 To +30V
Permissible Voltage At Input, Min. -5 V
Permissible Voltage At Input, Max. 30 V
Input Current
For Signal "1", Typ. 2.5 Ma
Input Delay (For Rated Value Of Input Voltage)
For Standard Inputs
— Parameterizable Yes; None / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 Ms
— At "0" To "1", Min. 4 Μs; For Parameterization "None"
— At "1" To "0", Min. 4 Μs; For Parameterization "None"
For Technological Functions
— Parameterizable Yes
Cable Length
Shielded, Max. 1 000 M
Unshielded, Max. 600 M
Digital Outputs
Number Of Digital Outputs 12; 3 Per Channel, Of Which 1 Diq
Current-Sinking Yes; For Dqn.0 And Dqn.1 Push-Pull Outputs
Current-Sourcing Yes
Digital Outputs, Parameterizable Yes
Short-Circuit Protection Yes; Electronic/Thermal
Response Threshold, Typ. 0.2 A For Dqn.0 And Dqn.1, 0.9 A For Diqn.2
Control Ling A Digital Input Yes
Digital Output Functions, Parameterizable
Pto (Pulse Train Output) Signal Interface
— 24 V Asymmetrical Yes
— Rs 422 Symmetrical Yes
— Ttl (5 V) Asymmetrical Yes
Pto (Pulse Train Output) Signal Type
— Pulse And Direction Yes
— Count Up, Count Down Yes
— Incremental Encoder (A, B Phase Shift) Yes
— Incremental Encoder (A, B Phase Shift, Quadruple) Yes
Switching Capacity Of The Outputs
With Resistive Load, Max. 0.1 A; 0.5 A For Diqn.2
On Lamp Load, Max. 1 W; 5 W For Diqn.2
Load Resistance Range
Lower Limit 240 Ω; 48 Ohms For Diqn.2
Upper Limit 12 Kω
Output Voltage
Type Of Output Voltage Dc
For Signal "1", Min. 23.2 V; L+ (-0.8 V), L+ (-1.3 V) For Diqn.2
Output Current
For Signal "1" Rated Value 0.1 A; 0.5 A For Diqn.2
For Signal "1" Permissible Range, Max. 0.12 A; 0.6 A For Diqn.2
For Signal "1" Minimum Load Current 2 Ma
For Signal "0" Residual Current, Max. 0.5 Ma
Output Delay With Resistive Load
"0" To "1", Typ. 1 Μs; 28 Μs For Diqn.2
"1" To "0", Typ. 1 Μs; 25 Μs For Diqn.2
Switching Frequency
With Resistive Load, Max. 1 Khz; For Diqn.2
With Inductive Load, Max. 0.5 Hz; According To Iec 60947-5-1, Dc-13, For Diqn.2
On Lamp Load, Max. 10 Hz; For Diqn.2
For Signal Interface 24 V Asymmetrical 200 Khz; With Dqn.0 And Dqn.1
For Signal Interface Rs 422 Symmetrical 1 Mhz
For Signal Interface Ttl (5 V) Asymmetrical 200 Khz
Cable Length
600 M; Cable Length, Rs 422 / Ttl Siemens Type 6Fx2001-5: 125 Khz, 320
Meters Shielded, Max.; 250 Khz, 160 Meters Shielded, Max.; 500 Khz, 60 Shielded, Max.
Meters Shielded, Max.; 1 Mhz, 32 Meters Shielded, Max. 24 V (Dqn.X /
Diqn.2): 10 Khz, 600 Meters, Shielded, Max. 200 Khz, 50 Meters Shielded,
Max.
Isochronous Mode
Bus Cycle Time (Tdp), Min. 250 Μs; 375 Μs If All 4 Channels Are Used
Jitter, Max. 1 Μs
Interrupts/Diagnostics/Status Information
Diagnostics Function Yes
Alarms
Diagnostic Alarm Yes
Diagnoses
Monitoring The Supply Voltage Yes
Short-Circuit Yes; Thermal Overload Protection
Group Error Yes
Diagnostics Indication Led
Run Led Yes; Green Led
Error Led Yes; Red Led
Maint Led Yes; Yellow Led
Monitoring Of The Supply Voltage (Pwr-Led) Yes; Green Led
Channel Status Display Yes; Green Led
For Channel Diagnostics Yes; Red Led
Potential Separation
Potential Separation Channels
Between The Channels No
Between The Channels And Backplane Bus Yes
Between The Channels And Load Voltage L+ No
Isolation
Isolation Tested With 707 V Dc (Type Test)

Ambient Temperature During Operation

Horizontal Installation, Min. 0 °C
Horizontal Installation, Max. 60 °C; Observe Derating
Vertical Installation, Min. 0 °C
Vertical Installation, Max. 40 °C; Observe Derating
Altitude During Operation Relating To Sea Level
Installation Altitude Above Sea Level, Max. 5 000 M; Restrictions For Installation Altitudes > 2 000 M, See Et 200Mp System
Manual
Decentralized Operation
To Simatic S7-300 Yes; Via Control And Feedback Interface
To Simatic S7-400 Yes; Via Control And Feedback Interface
To Simatic S7-1200 Yes
To Simatic S7-1500 Yes
To Standard Profinet Controller Yes; Via Control And Feedback Interface

Dimensions

Width 35 Mm
Height 147 Mm
Depth 129 Mm
Weight S
Weight , Approx. 300 G

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible