This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6ES7672-7FC01-0YG0

6ES7672-7FC01-0YG0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6ES7672-7FC01-0YG0 Siemens

6ES7672-7FC01-0YG0 Siemens - SIMATIC S7-1500 Failsafe Software Controller CPU 1507S F Single License for 1 installation, R-SW, software, docum. and license key download, R-SW Class A, 6 languages (de,en,it,fr,es,zh), executable in Windows 7 and Windows 10; reference hardware: SIMATIC IPC2x7E, IPC4x7E, IPC4x7D, IPC6x7E, IPC8x7E, IPC627D, IPC677D, IPC827D ******************************* Email address required for delivery

Free Delivery to UK Mainland on orders over £25

Direct from Manufacturer

Fetching stock
2 - 4 W.Weeks

£1,156.90 Exc. VAT
£1,388.28 Inc. VAT

Product

Article Number (Market Facing Number) 6ES7672-7FC01-0YG0
Product Description SIMATIC S7-1500 Failsafe Software Controller CPU 1507S F single license for 1 installation, runtime software, software, documentation and license key download, runtime software class A, 6 languages (de,en,it,fr,es,zh), executable in Windows 7 and Windows 10; reference hardware: SIMATIC IPC2x7E, IPC4x7E, IPC4x7D, IPC6x7E, IPC8x7E, IPC627D, IPC677D, IPC827D - - consignee email address required for delivery
Product family CPU 1507S F Windows
Product Lifecycle (PLM) PM300:Active Product
PLM Effective Date Product phase-out since: 01.01.2025
Notes This product is downloadable only.

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,001 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4047622450000
UPC 804766696343
Commodity Code Not available
LKZ_FDB/ CatalogID STWINAC
Product Group 4A72
Group Code R152
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Given
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation No
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Product Function

I&M Data Yes; I&M0 To I&M3
Engineering With
Step 7 Tia Portal Configurable/Integrated From Version V17
Configuration Control
Via Dataset Yes
Memory
Simatic Memory Card Required No; Use Of The Pc Mass Storage
Work Memory
Integrated (For Program) 7.5 Mbyte
Integrated (For Data) 20 Mbyte
Integrated (For Cpu Function Library Of Cpu Runtime) 50 Mbyte
Load Memory
Integrated (On Pc Mass Storage) 320 Mbyte
Backup
With Ups Yes; All Memory Areas Declared Retentive
With Non-Volatile Memory Yes; Depending On Pc Hardware
Cpu Processing Times
For Bit Operations, Typ. 1 Ns; On Ipc427E, Intel Xeon Processor
For Word Operations, Typ. 2 Ns; On Ipc427E, Intel Xeon Processor
For Fixed Point Arithmetic, Typ. 2 Ns; On Ipc427E, Intel Xeon Processor
For Floating Point Arithmetic, Typ. 2 Ns; On Ipc427E, Intel Xeon Processor
Cpu-Blocks
Number Of Elements (Total) 6 000; In Addition To Blocks Such As Dbs, Fbs And Fcs, Udts, Global
Constants, Etc. Are Also Regarded As Elements
Db
Number, Max. 5 999; Number Range: 1 To 65535
Size, Max. 16 Mbyte
Fb
Number, Max. 5 998; Number Range: 1 To 65535
Size, Max. 1 024 Kbyte
Fc
Number, Max. 5 999; Number Range: 1 To 65535
Size, Max. 1 024 Kbyte
Ob
Size, Max. 1 024 Kbyte
Number Of Free Cycle Obs 100
Number Of Time Alarm Obs 20
Number Of Delay Alarm Obs 20
Number Of Cyclic Interrupt Obs 20
Number Of Process Alarm Obs 50
Number Of Dpv1 Alarm Obs 3
Number Of Isochronous Mode Obs 1
Number Of Technology Synchronous Alarm Obs 2
Number Of Startup Obs 100
Number Of Asynchronous Error Obs 4
Number Of Synchronous Error Obs 2
Number Of Diagnostic Alarm Obs 1
Nesting Depth
Per Priority Class 24; Up To 8 Possible For F-Blocks
Counters, Timers And Their Retentivity
S7 Counter
Number 2 048
Retentivity
— Adjustable Yes
Iec Counter
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
S7 Times
Number 2 048
Retentivity
— Adjustable Yes
Iec Timer
Number Any (Only Limited By The Main Memory)
Retentivity
— Adjustable Yes
Data Areas And Their Retentivity
Retentive Data Area (Incl. Timers, Counters, Flags), Max. 135 Kbyte; On Simatic Ipc227E, Ipc277E, Ipc427D, Ipc477D, Ipc427E,
Ipc477E, Ipc627E, Ipc677E; 35 Kb On Simatic Ipc627D, Ipc677D And
Ipc827D
Extended Retentive Data Area (Incl. Timers, Counters, Flags), Max. 20 Mbyte; When Using Pc Mass Storage For Retentive Data
Flag
Size, Max. 16 Kbyte
Number Of Clock Memories 8; In 1 Memory Byte
Data Blocks
Retentivity Adjustable Yes
Retentivity Preset No
Local Data
Per Priority Class, Max. 64 Kbyte; Max. 16 Kb Per Block
Address Area
Number Of Io Modules 8 192
I/O Address Area
Inputs 32 Kbyte
Outputs 32 Kbyte
Subprocess Images
Number Of Subprocess Images, Max. 32
Hardware Configuration
Number Of Distributed Io Systems 20
Number Of Dp Masters
Via Pc Interfaces 1
Number Of Io Controllers
Via Pc Interfaces 1; Any Combination Of Rt Or Irt Interfaces
Time Of Day
Clock
Type Software Clock, Synchronizable, No Battery Backup
Deviation Per Day, Max. Depending On Pc Hardware
Operating Hours Counter
Number 16
Clock Synchronization
Supported Yes
To Dp, Master No
On Ethernet Via Ntp Yes
On Windows Clock, Device Yes
Interfaces
Number Of Interfaces 3
Number Of Profinet Interfaces 2; In Case Of I-Device Configuration, Only One Profinet Interface Is Supported
Number Of Profibus Interfaces 1
1. Interface
Interface Type Cp 1625
Number Of Connections 128
Interface Types
Rj 45 (Ethernet) Yes
— Transmission Rate, Max. 100 Mbit/S
— Industrial Ethernet Status Led Yes
Number Of Ports 2
Integrated Switch Yes
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes
Web Server Yes
Profinet Io Controller
Services
— Isochronous Mode Yes
— Direct Data Exchange Yes; Requirement: Irt And Isochronous Mode (Mrpd Optional)
— Shortest Clock Pulse 500 Μs
— Irt Yes
— Profienergy Yes
— Prioritized Startup Yes; Max. 32 Profinet Devices; If You Want To Use The "Prioritized Startup"
Functionality In Step 7 For The Profinet Interface Of The Cpu, The Cpu And
The Device Must Be Seperated By Means Of A Switch (E.G Scalance X205) Or
Cp1625
— Number Of Connectable Io Devices, Max. 256
— Of Which Io Devices With Irt, Max. 64
— Number Of Connectable Io Devices For Rt, Max. 256
— Of Which In Line, Max. 256
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Io Devices Changing During Operation (Partner
Ports), Supportedyes; The Cpu And Changing Io Devices Must Be Separated By A Switch (E.G.
Scalance X205)
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
Update Time For Irt
— For Send Cycle Of 250 Μs 250 Μs To 4 Ms
— For Send Cycle Of 500 Μs 500 Μs To 8 Ms
— For Send Cycle Of 1 Ms 1 Ms To 16 Ms
— For Send Cycle Of 2 Ms 2 Ms To 32 Ms
— For Send Cycle Of 4 Ms 4 Ms To 64 Ms
— With Irt And Parameterization Of "Odd" Send Cycles Update Time = Set "Odd" Send Clock (Any Multiple Of 125 Μs: 375 Μs, 625 Μs ... 3
875 Μs)
Update Time For Rt
— For Send Cycle Of 250 Μs 250 Μs To 128 Ms
— For Send Cycle Of 500 Μs 500 Μs To 256 Ms
— For Send Cycle Of 1 Ms 1 Ms To 512 Ms
— For Send Cycle Of 2 Ms 2 Ms To 512 Ms
— For Send Cycle Of 4 Ms 4 Ms To 512 Ms
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
Profinet Io Device
Services
— Pg/Op Communication Yes
— Isochronous Mode No
— Irt Yes
— Profienergy Yes
— Prioritized Startup Yes; If You Want To Use The "Prioritized Startup" Functionality In Step 7 For The
Profinet Interface Of The Cpu, The Cpu And The Device Must Be Separated
By Means Of A Switch (E.G. Scalance X205)
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
— Asset Management Record Yes
2. Interface
Interface Type Onboard Profinet / Ie Interface X2/X3 Of The Simatic Ipc, Intel Springville
I210T
Number Of Connections 128
Interface Types
Rj 45 (Ethernet) Yes
— Transmission Rate, Max. 100 Mbit/S
— Industrial Ethernet Status Led Yes
Number Of Ports 1
Integrated Switch No
Protocols
Profinet Io Controller Yes
Profinet Io Device Yes
Simatic Communication Yes
Open Ie Communication Yes
Web Server Yes
Media Redundancy No
Profinet Io Controller
Services
— Isochronous Mode No
— Irt No
— Profienergy Yes
— Prioritized Startup Yes; Max. 32 Profinet Devices; If You Want To Use The "Prioritized Startup"
Functionality In Step 7 For The Profinet Interface Of The Cpu, The Cpu And
The Device Must Be Separated By Means Of A Switch (E.G. Scalance X205)
— Number Of Connectable Io Devices For Rt, Max. 128
— Of Which In Line, Max. 128
— Number Of Io Devices That Can Be Simultaneously
Activated/Deactivated, Max.8
— Number Of Io Devices Per Tool, Max. 8
— Updating Times The Minimum Value Of The Update Time Also Depends On Communication Share
Set For Profinet Io, On The Number Of Io Devices, And On The Quantity Of
Configured User Data
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
Profinet Io Device
Services
— Isochronous Mode No
— Irt No
— Profienergy Yes
— Shared Device Yes
— Number Of Io Controllers With Shared Device, Max. 4
— Asset Management Record Yes
3. Interface
Interface Type Profibus With Cp 5622, Cp 5622 Onboard
Number Of Connections 44
Interface Types
Rs 485 Yes
Protocols
Profibus Dp Master Yes
Profibus Dp Device No
Simatic Communication Yes; No Pg/Step 7 Connection Possible
Profibus Dp Master
Max. Number Of Dp Devices 64
Services
— Equidistance No
— Isochronous Mode No
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
4. Interface
Interface Type Profibus With Cp 5623
Number Of Connections 44
Interface Types
Rs 485 Yes
Protocols
Profibus Dp Master Yes
Profibus Dp Device No
Simatic Communication Yes; No Pg/Step 7 Connection Possible
Profibus Dp Master
Max. Number Of Dp Devices 125
Services
— Equidistance No
— Isochronous Mode No
Address Area
— Inputs, Max. 8 Kbyte
— Outputs, Max. 8 Kbyte
Protocols
Profisafe Yes
Number Of Connections
Number Of Connections, Max. 128
Number Of Connections Reserved For Es/Hmi/Web 10
Number Of S7 Routing Paths 16
Redundancy Mode
Media Redundancy
— Mrp Yes
— Mrpd Yes; Requirement: Irt
— Switchover Time On Line Break, Typ. 200 Ms; For Mrp, Bumpless For Mrpd
— Number Of Stations In The Ring, Max. 50
Simatic Communication
Pg/Op Communication Yes
S7 Routing Yes
S7 Communication, As Server Yes
S7 Communication, As Client Yes
User Data Per Job, Max. 64 Kbyte; Bsend/Brcv: 64 Kb; Put/Get: 960 Bytes
Open Ie Communication
Tcp/Ip Yes
— Data Length, Max. 64 Kbyte
Iso-On-Tcp (Rfc1006) Yes
— Data Length, Max. 64 Kbyte
Udp Yes
— Data Length, Max. 2 Kbyte
— Udp Multicast Yes; 128 Multicast Circuits (Of Which Max. 5 Via Cp 1625)
Dhcp Yes
Dns Yes
Snmp Yes
Dcp Yes
Lldp Yes
Web Server
Http Yes
Https Yes
Opc Ua
Runtime License Required Yes; "Medium" License Required
Opc Ua Client Yes; Data Access (Read, Write), Method Call
— Application Authentication Yes
— Security Policies Yes; Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User Authentication Yes; "Anonymous" Or By User Name & Password
— Number Of Connections, Max. 40
— Number Of Nodes Of The Client Interfaces,
Recommended Max.5 000
— Number Of Elements For One Call Of
Opc_Ua_Nodegethandlelist/Opc_Ua_Readlist/Opc_Ua_Writelist,
Max.300
— Number Of Elements For One Call Of
Opc_Ua_Namespacegetindexlist, Max.20
— Number Of Elements For One Call Of
Opc_Ua_Methodgethandlelist, Max.100
— Number Of Simultaneous Calls Of The Client
Instructions For Session Management, Per Connection,
Max.1
— Number Of Simultaneous Calls Of The Client
Instructions For Data Access, Per Connection, Max.5
— Number Of Registerable Nodes, Max. 5 000
— Number Of Registerable Method Calls Of
Opc_Ua_Methodcall, Max.100
— Number Of Inputs/Outputs When Calling
Opc_Ua_Methodcall, Max.20
Opc Ua Server Yes; Data Access (Read, Write, Subscribe), Method Call, Custom Address Space
— Application Authentication Yes
— Security Policies Yes; Available Security Policies: None, Basic128Rsa15, Basic256Rsa15,
Basic256Sha256
— User Authentication Yes; "Anonymous" Or By User Name & Password
— Number Of Sessions, Max. 64
— Number Of Accessible Variables, Max. 200 000
— Number Of Registerable Nodes, Max. 50 000
— Number Of Subscriptions Per Session, Max. 20
— Sampling Interval, Min. 10 Ms
— Publishing Interval, Min. 10 Ms
— Number Of Server Methods, Max. 100
— Number Of Inputs/Outputs Per Server Method, Max. 20
— Number Of Monitored Items, Recommended Max. 10 000; For 1 S Sampling Interval And 1 S Send Interval
— Number Of Server Interfaces, Max. 10
— Number Of Nodes For User-Defined Server Interfaces,
Max.30 000
Further Protocols
Modbus Yes; Modbus Tcp
S7 Message Functions
Number Of Login Stations For Message Functions, Max. 32
Program Alarms Yes
Number Of Configurable Program Messages, Max. 10 000
Number Of Loadable Program Messages In Run, Max. 5 000
Number Of Simultaneously Active Program Alarms 1 000
Number Of Program Alarms 1 000
Number Of Alarms For System Diagnostics 200
Number Of Alarms For Motion Technology Objects 160
Test Commissioning Functions
Joint Commission (Team Engineering) Yes; Parallel Online Access Possible For Up To 10 Engineering Systems
Status Block Yes; Up To 8 Simultaneously
Single Step Yes
Number Of Breakpoints 8
Status/Control
Status/Control Variable Yes
Variables Inputs, Outputs, Memory Bits, Db, Times, Counters
Number Of Variables, Max.
— Of Which Status Variables, Max. 200
— Of Which Control Variables, Max. 200
Forcing
Forcing Yes
Forcing, Variables Inputs, Outputs
Number Of Variables, Max. 200
Diagnostic Buffer
Present Yes
Number Of Entries, Max. 1 000
— Of Which Powerfail-Proof 300
Traces
Number Of Configurable Traces 4
Memory Size Per Trace, Max. 512 Kbyte
Interrupts/Diagnostics/Status Information
Diagnostics Indication Led
Run/Stop Led Yes; Hw Led Of Simatic Ipc227E, Ipc427D/E, Ipc627D/E, Ipc827D,
Ipc677D/E
Error Led Yes; Hw Led Of Simatic Ipc227E, Ipc427D/E, Ipc627D/E, Ipc826D,
Ipc677D/E
Maint Led Yes; Hw Led Of Simatic Ipc227E, Ipc427D/E, Ipc627D/E, Ipc826D,
Ipc677D/E
Supported Technology Objects
Motion Control Yes; Note: The Number Of Technology Objects Affects The Cycle Time Of The Plc
Program; Selection Guide Via The Tia Selection Tool Or Sizer
Number Of Available Motion Control Resources For
Technology Objects4 800
Required Motion Control Resources
— Per Speed-Controlled Axis 40
— Per Positioning Axis 80
— Per Synchronous Axis 160
— Per External Encoder 80
— Per Output Cam 20
— Per Cam Track 160
— Per Probe 40
Positioning Axis
— Number Of Positioning Axes At Motion Control Cycle
Of 4 Ms (Typical Value)30; On Ipc427E, Intel Xeon Processor
— Number Of Positioning Axes At Motion Control Cycle
Of 8 Ms (Typical Value)60; On Ipc427E, Intel Xeon Processor
Control Ler
Pid_Compact Yes; Universal Pid Controller With Integrated Optimization
Pid_3Step Yes; Pid Controller With Integrated Optimization For Valves
Pid-Temp Yes; Pid Controller With Integrated Optimization For Temperature
Counting And Measuring
High-Speed Counter Yes
Standards, Approvals, Certificates
Highest Safety Class Achievable In Safety Mode
Performance Level According To Iso 13849-1 Ple
Sil Acc. To Iec 61508 Sil 3
Probability Of Failure (For Service Life Of 20 Years And Repair Time Of 100 Hours)
— Low Demand Mode: Pfdavg In Accordance With
Sil3< 2.00E-05
— High Demand/Continuous Mode: Pfh In Accordance
With Sil3< 1.00E-09
Hardware Requirement
Hardware Required Simatic Ipc2X7E, Ipc4X7D/E, Ipc627D, Ipc677D, Ipc827D: Configurations
With Nvram Required; Ipc6X7E, Ipc8X7E
Processor
Single-Core Processor No
Single-Core Processor With Hyper-Threading No
Multi-Core Processor Yes
Multi-Core Processor With Hyper-Threading Yes
Occupied Cores 1; For Multicore Processors With Activated Hyper-Threading, One Complete
Physical Core Is Reserved For The Cpu 1507S
Memory
Work Memory, Min. 4 Gbyte
Hard Disk Memory Required For Installation 720 Mbyte
Temporary Hard Disk Memory For Installation 230 Mbyte
Hard Disk Memory Required At Runtime 400 Mbyte

Operating Systems

Runs Under Operating System
Windows 7 Yes; Professional, Enterprise, Ultimate (32 Bit And 64 Bit); Windows Embedded
Standard 7 With Delivery Image Of The Simatic Ipc
Windows 10 Yes; Windows 10 Enterprise 2016 Ltsb, 64-Bit, Mui On Ipc2X7E, Ipc4X7E,
Ipc6X7D, Ipc8X7D; Windows 10 Enterprise 2019 Ltsc 64-Bit, Mui On
Ipc2X7E, Ipc4X7E, Ipc6X7E, Ipc8X7E
Configuration / Header
Configuration / Programming / Header
Programming Language
— Lad Yes; Incl. Failsafe
— Fbd Yes; Incl. Failsafe
— Stl Yes
— Scl Yes
— Cfc No
— Graph Yes
Know-How Protection
User Program Protection/Password Protection Yes
Copy Protection Yes
Block Protection Yes
Access Protection
Protection Level: Write Protection Yes
Protection Level: Read/Write Protection Yes
Protection Level: Write Protection For Failsafe Yes
Protection Level: Complete Protection Yes
Programming / Cycle Time Monitoring / Header
Lower Limit Adjustable Minimum Cycle Time
Upper Limit Adjustable Maximum Cycle Time
Open Development Interfaces
Size Of Odk So File, Max. 9.8 Mbyte

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible