This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6SL3130-6AE21-0AB1

6SL3130-6AE21-0AB1 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6SL3130-6AE21-0AB1 Siemens

6SL3130-6AE21-0AB1 Siemens - SINAMICS S120 SMART LINE MODULE INPUT: 3AC 380-480V, 50/60HZ OUTPUT: 600VDC, 17A, 10KW FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING INCL. CONTROL VOLTAGE ADAPTER MODULES PAINTED

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3130-6AE21-0AB1
Product Description SINAMICS S120 SMART LINE MODULE INPUT: 3AC 380-480V, 50/60HZ OUTPUT: 600VDC, 17A, 10KW FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING INCL. CONTROL VOLTAGE ADAPTER MODULES PAINTED
Product family Not available
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 4,800 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4034106439927
UPC 887621085629
Commodity Code 85044095
LKZ_FDB/ CatalogID D21MC
Product Group 9617
Group Code R220
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 18.07.2012
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Electrical Data

Input
Number Of Phases 3 Ac
Line Voltage 342 ... 528 V
Line Frequency 47 ... 63 Hz
Short-Circuit Strength 1)65 Ka
Line Power Factor
Fundamental Power Factor, Minimal .96
Total 0.65 ... 0.90
Overvoltage Category Class Iii
Dc Link Voltage 2)
Dc-Link Voltage 1.35 × Line Voltage
Electronics Power Supply With Dc 24 V (-15 % / 20 %)

Line Side

Design Screw-Type Terminal (X1)
Conductor Cross-Section 2.5 ... 6 Mm² (Awg 14 ... Awg 10)
Pe Conductor M5 Screw
Shield Connecting Kitcable Shield Connection Plate Integrated
Into The Connector

Line Length, Max.

Shielded 350 M (1,148.29 Ft)
Unshielded 560 M (1,837.27 Ft)

Mechanical Data

Degree Of Protection Ip20 / Ul Open Type
Type Of Construction Booksize
Net Weight 4.8 Kg (10.58 Lb)

Dimensions

Width 50 Mm (1.97 In)
Height 380 Mm (14.96 In)
Depth 270 Mm (10.63 In)

Standards

Compliance With Standards Ce, Culusrated Data
Infeed Power
Rated Value 10.0 Kw (10.0 Hp)
For S6 Duty 13.0 Kw
Maximum 20.0 Kw
Regenerative Feedback Power
Rated Value 10.0 Kw (10.0 Hp)
For S6 Duty 13.0 Kw
Maximum 20.0 Kw
Dc-Link Current
At 540 V Dc 18.5 A
At 600 V Dc 16.6 A
For S6 Duty 22.0 A
Maximum 33.2 A
Input Current
At 380 V Ac 3-Phase 17.0 A
At 400 V Ac 3-Phase 16.2 A
At 480 V Ac 3-Phase 12.8 A
At 400 V S6 Duty 21.1 A
At 400 V, Maximum 31.2 A
Current Requirement At 24 V Dc,
Maximum 0.90 A
Ampacity Of The Busbars
For Electronics Power Supply At
24 V Dc20 A
For Dc-Link Connection 100 A
Dc Link Capacitance
Of The Smart Line Module 330 Μf
Of The Drive System, Maximum 6,000 Μf
General Technical Specifications
Sound Pressure Level 60 Db
Losses 4)0.140 Kw

Ambient Conditions

Ambient Temperature In Operation 0 ... 40 °C (32 ... 104 °F)
Cooling Air Throughput 0.008 M³/S (0.283 Ft³/S)
Installation Altitude 1,000 M (3,280.84 Ft)
Type Of Cooling Internal Air Cooling
Ri Suppressionstandard: No Radio Interference
Suppression; With Line Filter: Category
C2 To En 61800‑3 Total Cable Length Up
To 350 M (1148 Ft) (Shielded)
1)In Conjunction With The Recommended Class J Fuse, Or Circuit Breaker According To Ul489 / Csa 22.2 No. 5-02
2)The Dc Link Voltage Is Maintained At The Mean Value Of The Rectified Line Voltage.
4)Power Loss Of The Smart Line Module With Rated Power Including Losses Of The 24 V Dc Electronics Power Supply

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible