6SL3130-7TE21-6AA4 Siemens - SINAMICS S120 ACTIVE LINE MODULE INPUT: 3-PH 380-480V, 50/60HZ OUTPUT: DC 600V, 27A, 16KW FRAME SIZE: BOOKSIZE INTERNE LUFTKUEHLUNG INKL. DRIVE-CLIQ LEITUNG

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3130-7TE21-6AA4
Product Description SINAMICS S120 ACTIVE LINE MODULE INPUT: 3-PH 380-480V, 50/60HZ OUTPUT: DC 600V, 27A, 16KW FRAME SIZE: BOOKSIZE INTERNE LUFTKUEHLUNG INKL. DRIVE-CLIQ LEITUNG
Product family Not available
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : 9N9999
Estimated dispatch time (Working Days) 15 Day/Days
Net Weight (kg) 7,000 Kg
Package size unit of measure Not available
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4034106439958
UPC 887621495695
Commodity Code 85044095
LKZ_FDB/ CatalogID D21MC
Product Group 9617
Group Code R220
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 04.02.2013
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Reach Information There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern. We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
SCIP number

Electrical Data

Input
Number Of Phases 3 Ac
Line Voltage 342 ... 528 V
Line Frequency 47 ... 63 Hz
Short-Circuit Strength 1)65 Ka
Line Power Factor
In Active Mode
Fundamental Power Factor Cos Phi
1 2) 1
Total 1
In Smart Mode
Fundamental Power Factor,
Minimal.96
Total 0.65 ... 0.90
Overvoltage Category Class Iii
Dc Link Voltage 3)
At 380 V ... 400 V Ac, Factory Setting 600 V
At 400 V ... 415 V Ac, Factory Setting 625 V
Dc-Link Voltage 1.35 X Line Voltage (Smart Mode)
Electronics Power Supply With Dc 24 V (-15 % / 20 %)

Line Side

Design Screw-Type Terminal (X1)
Conductor Cross-Section 2.50 ... 10.00 Mm² (Awg 14 ... Awg 8)
Pe Conductor M5 Screw
Shield Connecting Kit Integrated Connection Plug

Line Length, Max.

Shielded 4) 630 M (2,066.93 Ft)
Unshielded 850 M (2,788.71 Ft)

Mechanical Data

Degree Of Protection Ip20 / Ul Open Type
Type Of Construction Booksize
Net Weight 7.0 Kg (15.43 Lb)

Dimensions

Width 100 Mm (3.94 In)
Height 380 Mm (14.96 In)
Depth 270 Mm (10.63 In)Rated Data
Infeed Power
Rated Value 16 Kw (18 Hp)
For S6 Duty 21 Kw
Maximum 35 Kw
Regenerative Feedback Power
Rated Value 16 Kw (18 Hp)
For S6 Duty 21 Kw
Maximum 35 Kw
Dc-Link Current
At 600 V Dc 27 A
For S6 Duty 35 A
Maximum 59 A
Input Current
At 380 V Ac 3-Phase 26 A
At 400 V Ac 3-Phase 25 A
At 480 V Ac 3-Phase 21 A
At 400 V S6 Duty 32 A
At 400 V, Maximum 54 A
Current Requirement At 24 V Dc,
Maximum 1.1 A
Ampacity Of The Busbars
For Electronics Power Supply At
24 V Dc20 A
For Dc-Link Connection 100 A
Dc Link Capacitance
Of The Active Line Module 710 Μf
Of The Drive System, Maximum 20,000 Μf
General Technical Specifications
Sound Pressure Level 60 Db
Losses 10)0.28 Kw

Ambient Conditions

Ambient Temperature In Operation 0 ... 40 °C (32 ... 104 °F)
Cooling Air Throughput 0.016 M³/S (0.565 Ft³/S)
Installation Altitude 1,000 M (3,280.84 Ft)
Type Of Cooling 11)Internal Air Cooling
Ri Suppressionactive Line Module + Active Interface
Module: Category C3 According To En
61800-3 Up To 350 M (1148 Ft) Total
Cable Length. With Line Filter: Category
C2 According To En 61800-3 Up To 350
M (1148 Ft) Total Cable Length. Category
C3 According To En 61800-3 From 350
M To 1000 M (1148 ... 3281 Ft) Total
Cable Length.

Standards

Compliance With Standards Ce, Culus
Article No. : 6Sl3130-7Te21-6Aa4
Technical Data Are Subject To Change! There May Be Discrepancies Between Calculated And Rating Plate Values. Page 2 Of 2 Generated Mon Dec 23 12:17:20 Cet 2024
1)In Conjunction With The Recommended Class J Fuse, Or Circuit Breaker According To Ul489 / Csa 22.2 No. 5-02
2)Factory Setting Can Be Altered By Inputting A Reactive Current Setpoint (Active Mode)
3)In Active Mode, The Dc Link Voltage Is Regulated And Can Be Adjusted As A Voltage Decoupled From The Line Voltage. In Smart Mode, The Dc Link Voltage Is Kept In Proportion To The Line Voltage At The
Mean Rectified Line Voltage Value. For Line Voltages Of 416 ... 480 V Ac, Active Mode Can Also Be Selected If The Connected Motors Are Suitable For > 650 V Dc.
4)Max. Cable Lengths In Conjunction With Active Interface Module And Basic Line Filter (Category C3 In Accordance With En 61800-3).
10)Power Loss Of The Active Line Module With Rated Power Including Losses Of The 24 V Dc Electronics Power Supply
11)Power Units With Intensified Air Cooling Thanks To Integrated Fan

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible