This webshop is for business use only (B2B) – Orders accepted from registered companies and organisations only. Company details required at checkout.

Siemens

6SL3210-1NE21-8AL0

6SL3210-1NE21-8AL0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6SL3210-1NE21-8AL0 Siemens

6SL3210-1NE21-8AL0 Siemens - SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protection IP20 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 7.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 292x 100x 165 (HxWxD), FSB without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher Note: PM230 supported no safety

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3210-1NE21-8AL0
Product Description SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protection IP20 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 7.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 292x 100x 165 (HxWxD), FSB without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher Note: PM230 supported no safety
Product family Not available
Product Lifecycle (PLM) PM500:Discontinued Product or end of PLM & Support
PLM Effective Date End of product lifecycle since: 01.10.2020
Notes Product is no longer available. Successor: 6SL3210-1NE21-8AG1 Compare Products

Successor information

Successor 6SL3210-1NE21-8AG1
Successor Description SINAMICS G120 Power Module PM230 with integrated Class A filter Degree of protection IP20 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 7.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 292x 100x 165 (HxWxD), FSB without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher

Delivery information

Export Control Regulations ECCN : 3A999A / AL : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 3,000 Kg
Packaging Dimension 114,00 x 185,00 x 365,00
Package size unit of measure MM
Quantity Unit 0 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948661451
UPC 887621217976
Commodity Code 85044088
LKZ_FDB/ CatalogID D11.1SD
Product Group 9777
Group Code R220
Country of origin Great Britain
Compliance with the substance restrictions according to RoHS directive Since: 01.07.2006
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation No
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Rated Data

Input
Number Of Phases 3 Ac
Line Voltage 380 ... 480 V ±10 %
Line Frequency 47 ... 63 Hz
Rated Current (Lo) 19.00 A
Rated Current (Ho) 14.00 A
Output
Number Of Phases 3 Ac
Rated Voltage 400V Iec 480V Nec 1)
Rated Power (Lo) 7.50 Kw 10.00 Hp
Rated Power (Ho) 5.50 Kw 7.50 Hp
Rated Current (Lo) 18.00 A
Rated Current (Ho) 13.20 A
Max. Output Current 27.00 A
Pulse Frequency 4 Khz
Output Frequency For Vector Control 0 ... 200 Hz
Output Frequency For V/F Control 0 ... 550 Hz
Overload Capability
Low Overload (Lo)
1.1 X Rated Output Current (I.E. 110 % Overload) For 57 S With A Cycle Time Of
300 S 1.5 × Rated Output Current (I.E. 150 % Overload) For 3 S With A Cycle Time
Of 300 S
High Overload (Ho)
1.5 × Output Current Rating (I.E., 150 % Overload) For 57 S With A Cycle Time Of
300 S 2 × Output Current Rating (I.E., 200 % Overload) For 3 S With A Cycle Time
Of 300 S

General Tech. Specifications

Power Factor Λ 0.90
Offset Factor Cos Φ 0.95
Efficiency Η 0.97
Sound Pressure Level (1M) 62 Db
Power Loss 0.24 Kw
Filter Class (Integrated) Class A

Ambient Conditions

Cooling Internal Air Cooling
Cooling Air Requirement 0.009 M³/S (0.318 Ft³/S)
Installation Altitude 1,000 M (3,280.84 Ft)
Ambient Temperature
Operation Lo 0 ... 40 °C (32 ... 104 °F)
Operation Ho 0 ... 50 °C (32 ... 122 °F)
Transport -25 ... 55 °C (-13 ... 131 °F)
Storage -25 ... 55 °C (-13 ... 131 °F)
Relative Humidity
Max. Operation 95 % Rh, Condensation Not Permitted

Line Side

Version Plug-In Screw Terminals
Conductor Cross-Section 1.50 ... 6.00 Mm²
(Awg 16 ... Awg 10)

Motor End

Version Plug-In Screw Terminals
Conductor Cross-Section 1.50 ... 6.00 Mm²
(Awg 16 ... Awg 10)

Max. Motor Cable Length

Shielded 25 M (82.02 Ft)
Unshielded 100 M (328.08 Ft)

Mechanical Data

Degree Of Protection Ip20 / Ul Open Type
Frame Size Fsb
Net Weight 6.30 Kg (13.89 Lb)

Dimensions

Width 100 Mm (3.94 In)
Height 292 Mm (11.50 In)
Depth 165 Mm (6.50 In)

Standards

Compliance With Standards Ul, Ce, C-Tick (Rcm)
Ce Marking Low-Voltage Directive 2006/95/Ec
Article No. : 6Sl3210-1Ne21-8Al0
Technical Data Are Subject To Change! There May Be Discrepancies Between Calculated And Rating Plate Values. Page 2 Of 2 Generated Mon Dec 23 12:57:11 Cet 2024
Converter Losses To Iec61800-9-2*
Efficiency Class Ie2
Comparison With The Reference
Converter (90% / 100%)71.33 %
The Percentage Values Show The Losses In Relation To The Rated Apparent Power Of
The Converter.
The Diagram Shows The Losses For The Points (As Per Standard Iec61800-9-2) Of
The Relative Torque Generating Current (I) Over The Relative Motor Stator Frequency
(F). The Values Are Valid For The Basic Version Of The Converter Without
Options/Components.
*Calculated Values
1)The Output Current And Hp Ratings Are Valid For The Voltage Range 440V-480V104.3 W (0.84 %)
85.1 W (0.68 %)164.3 W (1.32 %) 183.8 W (1.47 %) 209.4 W (1.68 %)
123.1 W (0.99 %) 113.0 W (0.91 %)
89.3 W (0.72 %)
F 90% 50%25%50%I
100%

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible