6SL3210-1RH31-0AL0 Siemens - SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC500-690V+10/-20% 47-63Hz OUTPUT HIGH OVERLOAD: 75KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 90kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708x 305x 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3210-1RH31-0AL0
Product Description SINAMICS G120 POWER MODULE PM240P-2 WITH BUILT IN CL. A FILTER 3AC500-690V+10/-20% 47-63Hz OUTPUT HIGH OVERLOAD: 75KW FOR 150% 60S, 100% 240S; AMBIENT TEMP -20 TO +50 DEG C (HO) OUTPUT LOW OVERLOAD: 90kW FOR 135% 3S, 110% 57S, 100% 240S AMBIENT TEMP -20 TO +40 DEG C (LO) 708x 305x 357 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.7 SP6 HF1
Product family Not available
Product Lifecycle (PLM) PM400:Phase Out Started
PLM Effective Date Product phase-out since: 01.10.2023

Delivery information

Export Control Regulations AL : N / ECCN : EAR99H
Estimated dispatch time (Working Days) 25 Day/Days
Net Weight (kg) 65,000 Kg
Packaging Dimension 469,00 x 745,00 x 385,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4042948673720
UPC 804766459344
Commodity Code 85044086
LKZ_FDB/ CatalogID D11.1SD
Product Group 5678
Group Code R220
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Since: 22.12.2016
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Diboron trioxide Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Tris(2-chloroethyl) ... CAS-No. 115-96-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Tris(2-chloroethyl) phosphate (TCEP) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Rated Data

Input
Number Of Phases 3 Ac
Line Voltage 500 ... 690 V ±10 %
Line Frequency 47 ... 63 Hz
Rated Current (Lo) 97.00 A
Rated Current (Ho) 85.00 A
Output
Number Of Phases 3 Ac
Rated Voltage 690V Iec 600V Nec 1)
Rated Power (Lo) 90.00 Kw 100.00 Hp
Rated Power (Ho) 75.00 Kw 75.00 Hp
Rated Current (Lo) 100.00 A
Rated Current (Ho) 80.00 A
Max. Output Current 135.00 A
Pulse Frequency 2 Khz
Output Frequency For Vector Control 0 ... 200 Hz
Output Frequency For V/F Control 0 ... 550 Hz
Overload Capability
Low Overload (Lo)
1.1 X Rated Output Current (I.E. 110 % Overload) For 57 S With A Cycle Time Of
300 S 1.35 × Rated Output Current (I.E. 135 % Overload) For 3 S With A Cycle Time
Of 300 S
High Overload (Ho)
1.5 × Output Current Rating (I.E., 150 % Overload) For 60 S With A Cycle Time Of
300 S

General Tech. Specifications

Power Factor Λ 0.90
Offset Factor Cos Φ 0.99
Efficiency Η 0.99
Sound Pressure Level (1M) 68 Db
Power Loss 1.76 Kw
Filter Class (Integrated) Class A

Ambient Conditions

Cooling Internal Air Cooling
Cooling Air Requirement 0.153 M³/S (5.403 Ft³/S)
Installation Altitude 1,000 M (3,280.84 Ft)
Ambient Temperature
Operation Lo -20 ... 40 °C (-4 ... 104 °F)
Operation Ho -20 ... 50 °C (-4 ... 122 °F)
Transport -40 ... 70 °C (-40 ... 158 °F)
Storage -40 ... 70 °C (-40 ... 158 °F)
Relative Humidity
Max. Operation 95 % Rh, Condensation Not Permitted

Line Side

Version M10 Bolt
Conductor Cross-Section 35.00 ... 120.00 Mm²
(Awg 2 ... Awg -3)

Motor End

Version M10 Bolt
Conductor Cross-Section 35.00 ... 120.00 Mm²
(Awg 2 ... Awg -3)

Max. Motor Cable Length

Shielded 300 M (984.25 Ft)
Unshielded 450 M (1,476.38 Ft)

Mechanical Data

Degree Of Protection Ip20 / Ul Open Type
Frame Size Fsf
Net Weight 64.00 Kg (141.10 Lb)

Dimensions

Width 305 Mm (12.01 In)
Height 708 Mm (27.87 In)
Depth 357 Mm (14.06 In)

Standards

Compliance With Standards Ul, Cul, Ce, C-Tick (Rcm), Semi F47
Ce Marking Low-Voltage Directive 2006/95/Ec
Data Sheet For Sinamics Power Module Pm240P-2
Article No. : 6Sl3210-1Rh31-0Al0
Technical Data Are Subject To Change! There May Be Discrepancies Between Calculated And Rating Plate Values. Page 2 Of 2 Generated Tue Dec 17 09:27:53 Cet 2024
Converter Losses To Iec61800-9-2*
Efficiency Class Ie2
Comparison With The Reference
Converter (90% / 100%)35.70 %
The Percentage Values Show The Losses In Relation To The Rated Apparent Power Of
The Converter.
The Diagram Shows The Losses For The Points (As Per Standard Iec61800-9-2) Of
The Relative Torque Generating Current (I) Over The Relative Motor Stator Frequency
(F). The Values Are Valid For The Basic Version Of The Converter Without
Options/Components.
*Calculated Values
1)The Output Current And Hp Ratings Are Valid For The Voltage Range 550V-600V808.0 W (0.70 %)
618.0 W (0.50 %)1,340.0 W (1.10 %) 1,490.0 W (1.20 %) 1,750.0 W (1.50 %)
952.0 W (0.80 %) 866.0 W (0.70 %)
644.0 W (0.50 %)
F 90% 50%25%50%I
100%

Documentation

Looking for a specific part?

If the product you're searching for isn't listed, click below to submit your enquiry and one of our specialists will source it for you.

CTA image

Contact Us

Using one of the ways below contact us and we will get back to you as soon as possible