Siemens

6SL3521-1XE47-5AB0

6SL3521-1XE47-5AB0 Siemens

The product image shown is for illustration purposes only and may not be an exact representation of the product. Please refer to the item description for accurate information

Please note: Some products are subject to manufacturer minimum pack quantities. We will confirm this at time of order.

Description for 6SL3521-1XE47-5AB0 Siemens

6SL3521-1XE47-5AB0 Siemens - SINAMICS G115D wall-mounted Rated power: 7.5 kW for 3S 200%, 57S 150%, 240S 87% Radio interference suppression filter for Cat. C2 3AC380-480V+10/-10% 45-66Hz Ambient temp. -30 to +40°C size: FSC Protection class IP65/66 / UL Type 4X brake voltage 400 V AC repair switch Q4/2 for 400 V AC and Power M12 for 24 V DC and M12 for I/O and communication with looping through Q8/0 for motor connection without fieldbus

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6SL3521-1XE47-5AB0
Product Description SINAMICS G115D wall-mounted Rated power: 7.5 kW for 3S 200%, 57S 150%, 240S 87% Radio interference suppression filter for Cat. C2 3AC380-480V+10/-10% 45-66Hz Ambient temp. -30 to +40°C size: FSC Protection class IP65/66 / UL Type 4X brake voltage 400 V AC repair switch Q4/2 for 400 V AC and Power M12 for 24 V DC and M12 for I/O and communication with looping through Q8/0 for motor connection without fieldbus
Product family Not available
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations ECCN : N / AL : N
Estimated dispatch time (Working Days) 12 Day/Days
Net Weight (kg) 14,190 Kg
Packaging Dimension 560,00 x 180,00 x 315,00
Package size unit of measure MM
Quantity Unit 1 Piece
Packaging Quantity 1

Additional Product Information

EAN 4025515997436
UPC Not available
Commodity Code 85044095
LKZ_FDB/ CatalogID D31.2
Product Group X01L
Group Code R220
Country of origin Great Britain
Compliance with the substance restrictions according to RoHS directive Since: 16.07.2020
Product class A: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead monoxide (lead oxide) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Dodecachloropentacyclo[12... > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™) covering any of its individual anti- and syn-isomers or any combination thereof Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | Diboron trioxide CAS-No. 1303-86-2 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Diboron trioxide Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. | 2-(2H-benzotriazol-2... CAS-No. 3147-75-9 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): 2-(2H-benzotriazol-2-yl)-4-(1,1,3,3-tetramethylbutyl)phenol (UV-329) Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Rated Data

Input
Number Of Phases 3 Ac
Line Voltage 380 ... 480 V +10 % -10 %
Line Frequency 45 ... 66 Hz
Rated Current 17.11 A
Output
Number Of Phases 3 Ac
Rated Voltage 400 V
Rated Power Iec 400V (Ho) 7.50 Kw
Rated Power Nec 480V (Ho) 10.00 Hp
Rated Current (Ho) 19.00 A
Max. Output Current 38.00 A
Pulse Frequency 4 Khz
Output Frequency For Vector Control 0 ... 240 Hz
Output Frequency For V/F Control 0 ... 550 Hz
Overload Capability
High Overload (Ho)
200% × Base Load Current Ih For 3 S, Followed By 150% For 57 S Within A Cycle
Time Of 300S

Inputs / Outputs

Standard Digital Inputs
Number 1) 4
Switching Level: 0 → 1 11 V
Switching Level: 1 → 0 5 V
Max. Inrush Current 15 Ma

Fail-Safe Digital Inputs

Number 1
Digital Inputs / Outputs Parameterizable
Number 2
Ptc/ Kty Interface
1 Motor Temperature Sensor Input, Possible Sensor Ptc, Kty, Pt1000, Thermo
Click, Accuracy ±5 °Cgeneral Tech. Specifications
Power Factor Λ 0.00 ... 0.89
Offset Factor Cos Φ 0.99
Efficiency Η 0.98
Power Loss 0.246 Kw
Filter Class (Integrated) Rfi Suppression Filter For Category C2
Brake Voltage 400V Ac
Integrated Braking Resistor (Continuous
Braking Power P_Db / Peak Power
P_Max)20W / 200W

Ambient Conditions

Cooling Air Cooled By Integrated Fan
Installation Altitude 1,000 M (3,280.84 Ft)
Ambient Temperature
Operation -30 ... 55 °C (-22 ... 131 °F)
Transport -40 ... 70 °C (-40 ... 158 °F)
Storage -40 ... 70 °C (-40 ... 158 °F)
Relative Humidity
Max. Operation95 % At 40 °C (104 °F), Condensation
And Icing Not Permissible

Mechanical Data

Degree Of Protection Ip65/66 / Ul Type 4X
Frame Size Fsc
Net Weight 8.33 Kg (18.32 Lb)

Dimensions

Width 425 Mm (16.73 In)
Height 180 Mm (7.09 In)
Depth 169 Mm (6.65 In)
Closed-Loop Control Techniques
V/F Linear / Square-Law / Parameterizable Yes
V/F With Flux Current Control (Fcc) Yes
V/F Eco Linear / Square-Law Yes
Sensorless Vector Control Yes
Vector Control, With Sensor No
Encoderless Torque Control Yes
Torque Control, With Encoder No

Communication

Communication I/O Control (Without Fieldbus
Communication )
Version -/-
Article No. : 6Sl3521-1Xe47-5Ab0
Technical Data Are Subject To Change! There May Be Discrepancies Between Calculated And Rating Plate Values. Page 2 Of 2 Generated Fri Dec 20 12:24:18 Cet 2024
Control Option
Control Option Repair Switch

Connections

Connection Type
Version Connector With Daisy Chain
3Ac 400V Supply
Version 2X Q4/2
24 V Dc Power Supply
Variant External
Version 2X M12 Power

Digital I/O

Version M12
Motor
Version Q8/0
External Brake Resistor
Version Cable Gland (Standard)
Pe Connection
Version On Housing With M5 Screw

Max. Motor Cable Length

Shielded 15 M (49.21 Ft)
Converter Losses To Iec61800-9-2*
Efficiency Class Ie2
Comparison With The Reference
Converter (90% / 100%)31.44 %
The Percentage Values Show The Losses In Relation To The Rated Apparent Power Of
The Converter.
The Diagram Shows The Losses For The Points (As Per Standard Iec61800-9-2) Of
The Relative Torque Generating Current (I) Over The Relative Motor Stator Frequency
(F). The Values Are Valid For The Basic Version Of The Converter Without
Options/Components.
*Calculated Valuesstandards
Compliance With Standards Ul, Cul, Ce, C-Tick (Rcm), Eac, Kcc,
Semi F47, Reach
Ce Marking Emc Directive 2014/30/Ec, Low-Voltage
Directive 2014/35/Ec
1)4 Inputs Pnp, Not Isolated, Additional 2X Switcheable Di/Do
120.0 W (0.9 %)
97.8 W (0.7 %)187.0 W (1.4 %) 211.0 W (1.6 %) 246.0 W (1.9 %)
143.0 W (1.1 %) 130.0 W (1.0 %)
103.0 W (0.8 %)
F 90% 50%25%50%I
100%

Documentation