6XV18305HH10 Siemens - Siemens, 2 Cores, 1000m, Aluminium foil with a braided tin-plated copper wire screen Shield

Free Delivery to UK Mainland on orders over £25

Product

Article Number (Market Facing Number) 6XV1830-5HH10
Product Description Foundation Fieldbus Cable; bus cable for IEC 61158-2; sheath color yellow for non- Ex applications; 2-core shielded; stranded drain wire sold by the meter; delivery unit max. 1000 m minimum order quantity 20 m.
Product family Bus cables
Product Lifecycle (PLM) PM300:Active Product

Delivery information

Export Control Regulations AL : N / ECCN : N
Estimated dispatch time (Working Days) 1 Day/Days
Net Weight (kg) 0,098 Kg
Packaging Dimension 1,00 x 1,00 x 1,00
Package size unit of measure MM
Quantity Unit 1 Meter
Packaging Quantity 1
Minimum order quantity 20

Additional Product Information

EAN 4019169854375
UPC Not available
Commodity Code 85444991
LKZ_FDB/ CatalogID IK
Product Group 2428
Group Code R323
Country of origin Germany
Compliance with the substance restrictions according to RoHS directive Given
Product class C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back Obligation Yes
REACH Art. 33 Duty to inform according to the current list of candidates Lead CAS-No. 7439-92-1 > 0, 1 % (w / w) Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w): Lead Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
SCIP number

Electrical Data

Attenuation Factor Per Length
At 38.4 Khz / Maximum 0.003 Db/M
Impedance
Rated Value 100 Ω
At 31.25 Khz 100 Ω
At 38.4 Khz 100 Ω
Relative Symmetrical Tolerance
Of The Characteristic Impedance At 31.25 Khz 20 %
Of The Characteristic Impedance At 38.4 Khz 20 %
Loop Resistance Per Length / Maximum 46 M Ω/M
Shield Resistance Per Length / Maximum 10 Ω/ Km
Capacity Per Length / At 1 Khz 65 Pf/M
Inductance Per Length 0.75 Μh/M
Operating Voltage
Rms Value 300 V

Mechanical Data

Number Of Electrical Cores 2
Design Of The Shield Overlapped Aluminum-Clad Foil, Sheathed In A Braided Shield Of Tin-Plated
Copper Wires With Shield Wire
Type Of Electrical Connection / Fastconnect No
Outer Diameter
Of Inner Conductor 1.17 Mm
Of The Wire Insulation 2.85 Mm
Of The Inner Sheath Of The Cable 6.4 Mm
Of Cable Sheath 8.5 Mm
Symmetrical Tolerance Of The Outer Diameter / Of Cable Sheath 0.3 Mm
Material
Of The Wire Insulation Polyethylene (Pe)
Of Cable Sheath Pvc
Color
Of The Insulation Of Data Wires Blue/Brown
Of Cable Sheath Yellow
Bending Radius
With Single Bend / Minimum Permissible 34 Mm
With Multiple Bends / Minimum Permissible 68 Mm
Tensile Load / Maximum 100 N
Weight Per Length 98 Kg/Km

Ambient Conditions

Ambient Temperature
During Operation -40 ... +105 °C
During Storage -40 ... +105 °C
During Transport -40 ... +105 °C
During Installation -40 ... +105 °C
Note Electrical Properties Measured At 20 °C, Tests According To Din 47250 Part 4
Respectively Din Vde 0472
Ambient Condition / For Operation Transfer Rate Of Cable: 31.25 Kbit/S
Fire Behavior Flame Resistant According To Iec 60332-1-2
Class Of Burning Behaviour / According To En 13501-6 Eca
Chemical Resistance
To Mineral Oil Conditional Resistance
To Grease Conditional Resistance
To Water Conditional Resistance
Radiological Resistance / To Uv Radiation Resistant

Product Features, Product Functions, Product Components / General

Product Feature
Halogen-Free No
Silicon-Free Yes

Standards, Specifications, Approvals

Ul/Etl Listing / 300 V Rating Yes; C(Ul)Us, Cmg / Pltc / Sun Res
Ul/Etl Style / 600 V Rating No
Certificate Of Suitability
Eac Approval Yes
Rohs Conformity Yes
Marine Classification Association
American Bureau Of Shipping Europe Ltd. (Abs) No
French Marine Classification Society (Bv) No
Det Norske Veritas (Dnv) No
Germanische Lloyd (Gl) No
Lloyds Register Of Shipping (Lrs) No
Nippon Kaiji Kyokai (Nk) No
Polski Rejestr Statkow (Prs) No
Reference Code
According To Iec 81346-2 Wg
According To Iec 81346-2:2019 Wgb

Documentation